Product Model
150-C25NCR

Selling Points
- 11. Efficient Operation: The Allen-Bradley 150-C25NCR is designed to provide efficient operation of three-phase motors, ensuring optimal performance and energy savings.;
- 22. Customizable Current Limits: With selectable current limits of 150%, 250%, 350%, and 450% of full load current, this controller allows for precise control over motor operation.;
- 33. Compact Design: The compact design of the 150-C25NCR makes it easy to integrate into various industrial settings, saving space and improving overall system efficiency.;
- 44. Reliable Control: Featuring a 24V AC/DC control voltage and a 600V voltage rating, this controller ensures reliable operation in a wide range of industrial environments.;
- 55. Advanced Features: The controller includes advanced features such as selectable kick start times, initial torque settings, and soft stop options, allowing for customizable motor control strategies to meet specific application needs.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 17.501 |
Dimension Width | 18.491 | Lead Time | 52 |
Dimension Height | 9.195 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Pollution degree | 2 | Altitude | 2000 m |
EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 per IEC | EMC emission levels | Radiated emission: Class A per IEC |
Operating temperature | Open: -5 to 50 °C (23 to 122 °F) | Humidity | 5...95% noncondensing |
Rated surrounding temperature range without derating | -5 °C | Storage and transportation temperature | -25 °C |
Enclosure | Open type | Number of poles | Equipment is designed for 3-phase only for power circuit |
Mounting hole size | 4.6 mm | Selectable soft stop | Off, 100%, 200%, or 300% of the start time setting when wired |
Selectable initial torque | 15%, 25%, 35%, and 65% of locked rotor torque | Selectable kick start - 450% FLA | 0, 0.5, 1.0, or 1.5 s |
Function | Single direction | Internal bypass | Yes |
Tightening torque | 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm2 (4 AWG) wire in top terminal for line power terminal | Break | TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts |
Make | TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts | Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement |
Cable size | 2.5...25 mm2 (14...4 AWG) for line power terminals | Height | 139.7 mm (5.5 in) |
Depth | 110 mm (4.33 in) | Width | 44.8 mm (1.76 in) |
Shock | Opsal: 15 G | Weight | 0.964 |
Degree of protection (IP) | IP2X | Input ON-state current (IN1, IN2) | 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit |
Rated control power during start without fan | 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC | Input ON-state voltage, during start (IN1, IN2) | 85V AC @ 19.2V DC/19.2V AC minimum for control circuit |
Selectable current limit | 150%, 250%, 350%, and 450% of full load current | Input OFF-state voltage (IN1, IN2), max | 40V AC @ 17V DC/12V AC for control circuit |
Selectable start times | 2, 5, 10, 15, 20, 25, or 30 s | Selectable overload trip class | Trip Class 10, 15, or 20 |
Short circuit protection device performance (SCPD) type | Type 1 | Integrated motor overload protection | Yes |
Rated control supply voltage at DC | 24 V | Standard controller feature | Soft stop |
Rated operational current, max | TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts | Utilization category | TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts |
Type of contacts | TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts | Type of control circuit | TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts |
Conventional thermal current (Ith) | TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts | Type of current | TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts |
High capacity available fault current, max | 70kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for inside delta connected motors | Number of contacts | TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts |
Short-circuit protection device list | Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L | Input OFF-state current | <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit |
Rated control power during start with fan | 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC | Rated operational voltage | 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts |
Insulation voltage | Rated 600V AC per UL/CSA/NEMA for power circuit | Dielectric withstand | 2500V AC per IEC for power circuit |
Rated impulse voltage | 6 kV for power circuit | Overvoltage category | III per IEC for side mount auxiliary contacts |
Operating frequency | 50/60 Hz per UL/CSA/NEMA for power circuit | Repetitive peak voltage | 1600V per UL/CSA/NEMA for power circuit |
DV/DT protection | 1000V/μs for power circuit | Controller type | SMC-3 |
Rated control supply voltage at AC 60 Hz | 24 V | Rated control supply voltage at AC 50 Hz | 24 V |
Rated operating voltage Ue | 200 | Voltage type for actuating | AC/DC |
With display | No | Product Family | SMC-3 |
Specifications may be subject to change without notice