Product Model
150-C480NCR

Selling Points
- 11. Efficient Operation: Designed for efficient operation of 3-phase motors, the Allen Bradley 150-C480NCR minimizes energy consumption while maximizing performance.;
- 22. Reliable Safety Features: Equipped with a short circuit relay bypass and built-in overload relay for each phase, this controller ensures reliable and safe motor operation.;
- 33. High Overvoltage Protection: Capable of handling high overvoltage conditions up to 6 kV in a type III category, the 150-C480NCR protects your motor from electrical surges.;
- 44. Remote Reset Solenoid: The remote reset solenoid allows for easy and convenient reset of the controller, reducing downtime and increasing productivity.;
- 55. Temperature and ESD Protection: With a rating of 8 kV for air discharge and 4 kV for contact discharge, this controller ensures temperature protection and electrostatic discharge safety.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 40.894 |
Dimension Width | 41.3 | Lead Time | 22 |
Dimension Height | 71.704 | Quick Turnaround | false |
Preferred Availability | false | Repairable | REPAIRABLE |
Pollution degree | 2 | Altitude | 2000 m |
EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 per IEC | EMC emission levels | Radiated emission: Class A per IEC |
Operating temperature | Open: -5 to 50 °C (23 to 122 °F) | Humidity | 5...95% noncondensing |
Rated surrounding temperature range without derating | -5 °C | Storage and transportation temperature | -25 °C |
Enclosure | Open type | Number of poles | Equipment is designed for 3-phase only for power circuit |
Mounting hole size | 11.5 mm | Selectable soft stop | Off, 100%, 200%, or 300% of the start time setting when wired |
Selectable initial torque | 15%, 25%, 35%, and 65% of locked rotor torque | Selectable kick start - 450% FLA | 0, 0.5, 1.0, or 1.5 s |
Function | Single direction | Internal bypass | Yes |
Tightening torque | 0.45...0.9 Nm (4.0...8.0 in-lb) for control terminals | Break | TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts |
Make | TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts | Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement |
Cable size | 0.2...2.5 mm2 (24...14 AWG) for control terminals | Height | 600 mm (23.62 in) |
Width | 290 mm (11.42 in) | Shock | Opsal: 15 G |
Weight | 45.178 | Degree of protection (IP) | IP2X |
Input ON-state current (IN1, IN2) | 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit | Input ON-state voltage, during start (IN1, IN2) | 85V AC @ 19.2V DC/19.2V AC minimum for control circuit |
Selectable current limit | 150%, 250%, 350%, and 450% of full load current | Input OFF-state voltage (IN1, IN2), max | 40V AC @ 17V DC/12V AC for control circuit |
Selectable start times | 2, 5, 10, 15, 20, 25, or 30 s | Selectable overload trip class | Trip Class 10, 15, or 20 |
Short circuit protection device performance (SCPD) type | Type 1 | Integrated motor overload protection | Yes |
Rated control supply voltage at DC | 24 V | Standard controller feature | Soft stop |
Rated operational current, max | TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts | Utilization category | TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts |
Type of contacts | TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts | Type of control circuit | TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts |
Conventional thermal current (Ith) | TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts | Type of current | TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts |
High capacity available fault current, max | 69kA @ 600V, maximum current 800 A time delay Class J or Class L fuse for line connected motors | Number of contacts | TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts |
Short-circuit protection device list | Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L | Input OFF-state current | <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit |
Rated control power during start with fan | 200mA @ 120V AC/120mA @ 240V AC, 600mA @ 24V AC/DC | Rated operational voltage | 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts |
Insulation voltage | Rated 600V AC per UL/CSA/NEMA for power circuit | Delta connected motor current | 277...831A @ 500/575V AC, 3-phase |
Dielectric withstand | 2500V AC per IEC for power circuit | Rated impulse voltage | 6 kV for power circuit |
Overvoltage category | III per IEC for side mount auxiliary contacts | Operating frequency | 50/60 Hz per UL/CSA/NEMA for power circuit |
Repetitive peak voltage | 1600V per UL/CSA/NEMA for power circuit | DV/DT protection | 1000V/μs for power circuit |
Controller type | SMC-3 | Rated control supply voltage at AC 60 Hz | 24 V |
Rated control supply voltage at AC 50 Hz | 24 V | Rated operating voltage Ue | 200 |
Voltage type for actuating | AC/DC | With display | No |
Product Family | SMC-3 |
Specifications may be subject to change without notice