Product Model
150-F108NBRB

Selling Points
- 11. Advanced Motor Control: The Allen-Bradley 150-F108NBD offers multiple operating modes, including Soft Start, Full Voltage Start, Smart Motor Braking, and Current Limit Start, ensuring smooth and precise motor control.;
- 22. Comprehensive Protection: Equipped with advanced diagnostic and protective functions, this controller safeguards the motor from degradation, power outages, line faults, voltage imbalance, and excessive starts per hour.;
- 33. Flexible Communication: With two DPIs (Drive Peripheral Interfaces), the controller facilitates easy integration into existing configurations and supports communication networks, enhancing system connectivity and control.;
- 44. Versatile Power Management: Compatible with a wide range of power sources (100-240V AC), this controller can manage a maximum output current of 108A and a maximum output power of 75 HP, making it suitable for various industrial applications.;
- 55. Compact Design: The controller’s compact dimensions (15 kg, 196.4 mm width, 212.2 mm depth, and 443.7 mm height) make it an ideal choice for locations with limited space, ensuring efficient installation and operation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 30.81 |
Dimension Width | 34.29 | Lead Time | 10 |
Dimension Height | 64.389 | Quick Turnaround | false |
Preferred Availability | false | Repairable | REPAIRABLE |
Metal parts construction | Plated brass, copper or painted steel | Control modules construction | Thermoset and thermoplastic moldings |
Enclosure | Open type | Number of poles | 3 |
Line/load side power terminals | One M10 x 1.5 diam hole per power pole | Control terminals | ClAing yoke connection, M3 screw clA |
Power terminal markings | NEMA, CENELEC EN50 012 | Function | Single direction |
Internal bypass | Yes | Break | 360VA for auxiliary contacts |
Make | 3600VA for auxiliary contacts | Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement |
Power pole construction | Heatsink hockey puck thyristor modular design | Height | 443.7 mm (17.47 in) |
Depth | 212.2 mm (8.35 in) | Width | 196.4 mm (7.74 in) |
Shock | Opsal: 5.5 G | Weight | 15.762 |
Pollution degree | 2 | Altitude | 2000 m |
EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 | EMC emission levels | Radiated emission: Class A |
Protection against electrical shock | IP2X (with terminal covers) per IEC for power circuit | Operating temperature | Open: -5 to 50 °C (23 to 122 °F) |
Humidity | 5...95% (noncondensing) | Storage and transportation temperature | -20 |
Steady state heat dissipation with control and fan power | 91 W | Contact type | Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4) |
Input ON-state current | 20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit | Rated operational current | 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts |
Input ON-state voltage, min | 85V AC @ 19.2V DC/20.4V AC for control circuit | Input OFF-state voltage, max | 50V AC @ 10V DC/12V AC for control circuit |
Reset resistance | 1600 ? ± 100 ? for PTC input ratings | Response resistance | 3400 ? ± 150 ? for PTC input ratings |
Short circuit trip resistance | 25 ? ± 10 ? for PTC input ratings | Allen bradley power supply control module, min | 1606-XLP50E @ 24V DC (-15%, +10%) |
Tachometer input | 0...5V DC @ 4.5V DC = 100% Speed | Cold resistance of PTC sensor chain, max | 1500 ? for PTC input ratings |
Transient time control module | 500 ms @ 24V DC (-15%, +10%) | Inrush time control module | 250 ms @ 24V DC (-15%, +10%) |
Response time | 800 ms for PTC input ratings | Voltage at PTC terminals (RPTC = 4 kΩ), max | <7.5 for PTC input ratings |
Steady state watts control module | 24 W @ 24V DC (-15%, +10%) | Transient watts control module | 60 W @ 24V DC (-15%, +10%) |
Voltage at PTC terminals (RPTC = open), max | 30V for PTC input ratings | Inrush current control module | 5A @ 24V DC (-15%, +10%) |
Number of sensors, max | 6 for PTC input ratings | Short circuit protection device performance (SCPD) type | Type 1 |
Integrated motor overload protection | Yes | Rated control supply voltage at DC | 24 V |
Optional controller feature | SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motorâs full-load current rating | Standard available fault current, max | 70kA @ 690V for maximum FLC |
Standard controller feature | Status indication: stopped, starting, stopping, at speed, alarm and fault | Utilization category | MG 1 per UL/CSA/NEMA for power circuit |
Type of contacts | Progmable NO/NC for auxiliary contacts | Type of control circuit | Electromagnetic relay for auxiliary contacts |
Conventional thermal current (Ith) | AC/DC: 5 A for auxiliary contacts | Type of current | AC for auxiliary contacts |
High capacity available fault current, max | 70kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors | Number of contacts | 1 for auxiliary contacts |
Short-circuit protection device list | Standard fuse, circuit breaker and high capacity time delay class CC/J/L | Input OFF-state current | <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage |
Rated operational voltage | 200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit | Insulation voltage | Rated 500V per IEC for power circuit |
Transient protection | Metal oxide varistors: 220 J (optional) for power circuit | Ampere tested north american style, max | A070URD33xxx500 @ 690V for maximum FLC |
Ampere tested european style, max | 6,9 gRB 73xxx400 6,6URD33xxx500 @ 690V for maximum FLC | Delta connected motor current | 47...187A @ 500/575V AC, 3-phase |
Line connected motor current | 27...108 A @ 600/Y/690V AC, 3-phase | Dielectric withstand | 2500V per IEC for power circuit |
Rated impulse voltage | 6000V per IEC for power circuit | Delta connected motor power, max | 90 kW @ 400/415V AC @ 50Hz, 3-phase |
Line connected motor power, max | 90 kW @ 690V/Y AC, 50 Hz, 3-phase | Operating frequency | 50/60 Hz for power circuit |
Repetitive peak inverse voltage rating | 1400V per UL/CSA/NEMA for power circuit | DV/DT protection | RC snubber network for power circuit |
Heatsink fan rating | 20VA @ 110/120V AC or 220/240V AC | Transformer control module | 75VA @ 100...240V AC (-15%, +10%) |
Trip current rating | 117% of motor FLC | Trip classes | 10, 15, 20 and 30 |
Control options | Pump control | Controller type | Soft starter |
Overload current for delta connected devices | 47 A | Overload current for line connected devices | 27 A |
Rated control supply voltage at AC 60 Hz | 24 V | Rated control supply voltage at AC 50 Hz | 24 V |
Rated operating voltage Ue | 200 | Voltage type for actuating | AC/DC |
With display | Yes | Product Family | SMC Flex |
Controller Rating | 108 A 20-75Hp @ 460V AC |
Specifications may be subject to change without notice