Product Model
150-F1250NBA

Selling Points
- 11. High Performance Motor Control: The Allen Bradley 150-F1250NBA SMC Flex Solid State Controller is designed to handle demanding industrial applications with its robust motor control capabilities, ensuring reliable and consistent operation even in harsh environments.;
- 22. Advanced Protection Features: Equipped with built-in overload protection, this controller helps prevent damage to your equipment and ensures safe and efficient operation at all times. It also features transient protection, which safeguards against electrical surges and spikes.;
- 33. Flexible Programming Options: The controller offers flexible programming options through an intuitive LCD and keypad interface. This allows users to easily configure and monitor parameters such as ramp time and acceleration profiles, making it easier to tailor the controller to specific applications.;
- 44. Robust Communication Capabilities: With built-in EtherNet/IP connectivity, the 150-F1250NBA seamlessly integrates into your existing network infrastructure. This enables real-time data monitoring and control, enhancing operational efficiency and reducing downtime caused by faults or overloads.;
- 55. Compact Design and Versatility: The compact design of the 150-F1250NBA saves space in electrical panels, making it an excellent option for both new installations and retrofits. Its versatility in supporting a wide range of starting modes and special operating modes further enhances its utility in various industrial settings.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 77.394 |
Dimension Width | 127.889 | Lead Time | 10 |
Dimension Height | 55.499 | Quick Turnaround | false |
Preferred Availability | false | Repairable | REPAIRABLE |
Metal parts construction | Plated brass, copper or painted steel | Control modules construction | Thermoset and thermoplastic moldings |
Enclosure | Open type | Number of poles | 3 |
Line/load side power terminals | Two 13.5 mm (0.53 in) diam holes per power pole | Control terminals | ClAing yoke connection, M3 screw clA |
Power terminal markings | NEMA, CENELEC EN50 012 | Function | Single direction |
Internal bypass | Yes | Break | 360VA for auxiliary contacts |
Make | 3600VA for auxiliary contacts | Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement |
Power pole construction | Heatsink hockey puck thyristor modular design | Height | 1041.1 mm (41 in) |
Depth | 346.2 mm (13.63 in) | Width | 596.9 mm (23.50 in) |
Shock | Opsal: 4 G | Weight | 228.611 |
Pollution degree | 2 | Altitude | 2000 m |
EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 | EMC emission levels | Radiated emission: Class A |
Protection against electrical shock | IP00 (open device) per IEC for power circuit | Operating temperature | Open: -5 to 50 °C (23 to 122 °F) |
Humidity | 5...95% (noncondensing) | Storage and transportation temperature | -20 |
Steady state heat dissipation with control and fan power | 1222 W | Contact type | Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4) |
Input ON-state current | 20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit | Rated operational current | 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts |
Input ON-state voltage, min | 85V AC @ 19.2V DC/20.4V AC for control circuit | Input OFF-state voltage, max | 50V AC @ 10V DC/12V AC for control circuit |
Reset resistance | 1600 ? ± 100 ? for PTC input ratings | Response resistance | 3400 ? ± 150 ? for PTC input ratings |
Short circuit trip resistance | 25 ? ± 10 ? for PTC input ratings | Tachometer input | 0...5V DC @ 4.5V DC = 100% Speed |
Cold resistance of PTC sensor chain, max | 1500 ? for PTC input ratings | Response time | 800 ms for PTC input ratings |
Transformer rating control module | 751 VA (recommended 800 VA) | Voltage at PTC terminals (RPTC = 4 kΩ), max | <7.5 for PTC input ratings |
Voltage at PTC terminals (RPTC = open), max | 30V for PTC input ratings | Number of sensors, max | 6 for PTC input ratings |
Short circuit protection device performance (SCPD) type | Type 1 | Integrated motor overload protection | Yes |
Optional controller feature | SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motorâs full-load current rating | Standard available fault current, max | 85kA @ 690V for maximum FLC |
Standard controller feature | Status indication: stopped, starting, stopping, at speed, alarm and fault | Utilization category | MG 1 per UL/CSA/NEMA for power circuit |
Type of contacts | Progmable NO/NC for auxiliary contacts | Type of control circuit | Electromagnetic relay for auxiliary contacts |
Conventional thermal current (Ith) | AC/DC: 5 A for auxiliary contacts | Type of current | AC for auxiliary contacts |
High capacity available fault current, max | 85kA @ 600V, maximum current 3000 A time delay Class J or Class L fuse for line connected motors | Number of contacts | 1 for auxiliary contacts |
Short-circuit protection device list | Standard fuse, circuit breaker and high capacity time delay class CC/J/L | Input OFF-state current | <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage |
Rated operational voltage | 200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit | Insulation voltage | Rated 500V per IEC for power circuit |
Transient protection | Metal oxide varistors: 220 J (optional) for power circuit | Ampere tested north american style, max | Two fuses in parallel A070URD33xxx1250 @ 690V for maximum FLC |
Ampere tested european style, max | Two fuses in parallel 6,6URD33xxx1250 @ 690V for maximum FLC | Delta connected motor current | 533...1600A @ 500/575V AC, 3-phase |
Line connected motor current | 416...1250 A @ 600/Y/690V AC, 3-phase | Dielectric withstand | 2500V per IEC for power circuit |
Rated impulse voltage | 6000V per IEC for power circuit | Delta connected motor power, max | 900 kW @ 400/415V AC @ 50Hz, 3-phase |
Line connected motor power, max | 900 kW @ 500V AC @ 50Hz, 3-phase | Operating frequency | 50/60 Hz for power circuit |
Repetitive peak inverse voltage rating | 1400V per UL/CSA/NEMA for power circuit | DV/DT protection | RC snubber network for power circuit |
Heatsink fan rating | 150VA @ 110/120V AC or 220/240V AC | Trip current rating | 117% of motor FLC |
Trip classes | 10, 15, 20 and 30 | Control options | None |
Controller type | Soft starter | Overload current for delta connected devices | 533 A |
Overload current for line connected devices | 416 A | Rated control supply voltage at AC 60 Hz | 230 V |
Rated control supply voltage at AC 50 Hz | 230 V | Rated operating voltage Ue | 200 |
Voltage type for actuating | AC | With display | Yes |
Product Family | SMC Flex | Controller Rating | 1250 A 1000Hp @ 460V AC |
Control Voltage | 230...240V AC |
Specifications may be subject to change without notice