Product Model
150-F1250NCAB

Selling Points
- 11. High Power Capacity: The Allen Bradley 150-F1250NCAB delivers significant power with a capacity of 1250 A and 1000 Hp at 460 Volts AC, making it ideal for high-power motor control applications.;
- 22. Advanced Soft Starting: Equipped with microprocessor-controlled soft starting capabilities, this controller ensures smooth and reliable motor operation, reducing wear and tear on the motor.;
- 33. Comprehensive Protection: Featuring programmable contacts and comprehensive protection features such as under/over voltage and phase reversal protections, the 150-F1250NCAB provides robust safety and reliability.;
- 44. Detailed Monitoring: With built-in metering capabilities, this controller allows detailed monitoring of electrical parameters including kW, kWh, and motor thermal capacity, enhancing operational efficiency and maintenance.;
- 55. Versatile Control Options: Supporting a range of starting modes and control options like brake control, the 150-F1250NCAB offers flexibility in motor control, making it suitable for various industrial applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 128.905 |
Dimension Width | 77.47 | Lead Time | 22 |
Dimension Height | 55.601 | Quick Turnaround | false |
Preferred Availability | false | Repairable | REPAIRABLE |
Metal parts construction | Plated brass, copper or painted steel | Control modules construction | Thermoset and thermoplastic moldings |
Enclosure | Open type | Number of poles | 3 |
Line/load side power terminals | Two 13.5 mm (0.53 in) diam holes per power pole | Control terminals | ClAing yoke connection, M3 screw clA |
Power terminal markings | NEMA, CENELEC EN50 012 | Function | Single direction |
Internal bypass | Yes | Break | 360VA for auxiliary contacts |
Make | 3600VA for auxiliary contacts | Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement |
Power pole construction | Heatsink hockey puck thyristor modular design | Height | 1041.1 mm (41 in) |
Depth | 346.2 mm (13.63 in) | Width | 596.9 mm (23.50 in) |
Shock | Opsal: 4 G | Weight | 68.027 |
Pollution degree | 2 | Altitude | 2000 m |
EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 | EMC emission levels | Radiated emission: Class A |
Protection against electrical shock | IP00 (open device) per IEC for power circuit | Operating temperature | Open: -5 to 50 °C (23 to 122 °F) |
Humidity | 5...95% (noncondensing) | Storage and transportation temperature | -20 |
Steady state heat dissipation with control and fan power | 1222 W | Contact type | Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4) |
Input ON-state current | 20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit | Rated operational current | 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts |
Input ON-state voltage, min | 85V AC @ 19.2V DC/20.4V AC for control circuit | Input OFF-state voltage, max | 50V AC @ 10V DC/12V AC for control circuit |
Reset resistance | 1600 ? ± 100 ? for PTC input ratings | Response resistance | 3400 ? ± 150 ? for PTC input ratings |
Short circuit trip resistance | 25 ? ± 10 ? for PTC input ratings | Tachometer input | 0...5V DC @ 4.5V DC = 100% Speed |
Cold resistance of PTC sensor chain, max | 1500 ? for PTC input ratings | Response time | 800 ms for PTC input ratings |
Transformer rating control module | 751 VA (recommended 800 VA) | Voltage at PTC terminals (RPTC = 4 kΩ), max | <7.5 for PTC input ratings |
Voltage at PTC terminals (RPTC = open), max | 30V for PTC input ratings | Number of sensors, max | 6 for PTC input ratings |
Short circuit protection device performance (SCPD) type | Type 1 | Integrated motor overload protection | Yes |
Optional controller feature | SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motorâs full-load current rating | Standard available fault current, max | 85kA @ 690V for maximum FLC |
Standard controller feature | Status indication: stopped, starting, stopping, at speed, alarm and fault | Utilization category | MG 1 per UL/CSA/NEMA for power circuit |
Type of contacts | Progmable NO/NC for auxiliary contacts | Type of control circuit | Electromagnetic relay for auxiliary contacts |
Conventional thermal current (Ith) | AC/DC: 5 A for auxiliary contacts | Type of current | AC for auxiliary contacts |
High capacity available fault current, max | 85kA @ 600V, maximum current 3000 A time delay Class J or Class L fuse for line connected motors | Number of contacts | 1 for auxiliary contacts |
Short-circuit protection device list | Standard fuse, circuit breaker and high capacity time delay class CC/J/L | Input OFF-state current | <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage |
Rated operational voltage | 200...600V AC (-15%, +10%) per UL/CSA/NEMA for power circuit | Insulation voltage | Rated 500V per IEC for power circuit |
Transient protection | Metal oxide varistors: 220 J (optional) for power circuit | Ampere tested north american style, max | Two fuses in parallel A070URD33xxx1250 @ 690V for maximum FLC |
Ampere tested european style, max | Two fuses in parallel 6,6URD33xxx1250 @ 690V for maximum FLC | Delta connected motor current | 533...1600A @ 500/575V AC, 3-phase |
Line connected motor current | 416...1250 A @ 600/Y/690V AC, 3-phase | Dielectric withstand | 2500V per IEC for power circuit |
Rated impulse voltage | 6000V per IEC for power circuit | Delta connected motor power, max | 900 kW @ 400/415V AC @ 50Hz, 3-phase |
Line connected motor power, max | 900 kW @ 500V AC @ 50Hz, 3-phase | Operating frequency | 50/60 Hz for power circuit |
Repetitive peak inverse voltage rating | 1600V per UL/CSA/NEMA for power circuit | DV/DT protection | RC snubber network for power circuit |
Heatsink fan rating | 150VA @ 110/120V AC or 220/240V AC | Trip current rating | 117% of motor FLC |
Trip classes | 10, 15, 20 and 30 | Control options | Pump control |
Controller type | Soft starter | Overload current for delta connected devices | 533 A |
Overload current for line connected devices | 416 A | Rated control supply voltage at AC 60 Hz | 230 V |
Rated control supply voltage at AC 50 Hz | 230 V | Rated operating voltage Ue | 200 |
Voltage type for actuating | AC | With display | Yes |
Product Family | SMC Flex | Controller Rating | 1250 A 1000Hp @ 460V AC |
Control Voltage | 230...240V AC |
Specifications may be subject to change without notice