Product Model
150-F480NBRD

Selling Points
- 11. High Performance and Efficiency: The Allen-Bradley 150-F480NBD delivers consistent performance in a variety of industrial applications, ensuring high efficiency and reliability. Its advanced features and sophisticated diagnostics make it perfect for regulating three-phase motors, reducing mechanical stress and increasing their lifespan.;
- 22. Heavy-Duty Motor Control: With a maximum output current of 480A, this motor controller is capable of controlling heavy-duty motors with ease. It operates at voltages ranging from 200 to 460V AC, making it compatible with a broad range of industrial power systems.;
- 33. Advanced Diagnostics and Monitoring: The 150-F480NBD features a display screen that allows users to see data as it happens and quickly access the settings menu. This real-time monitoring enhances troubleshooting and maintenance processes, ensuring the system operates at optimal levels.;
- 44. Internal Bypass for Improved Efficiency: The internal bypass feature reduces heat production and energy consumption, making the system more efficient and reliable. This function is particularly beneficial in applications where energy conservation is crucial.;
- 55. Durable Construction and Easy Maintenance: The open enclosure design of the 150-F480NBD facilitates easy access for maintenance and effective heat dissipation. Constructed with plated brass, copper, or painted steel, this motor controller is built to endure the tough conditions found in industrial settings, ensuring a long service life.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 40.589 |
Dimension Width | 41.605 | Lead Time | 22 |
Dimension Height | 71.4 | Quick Turnaround | false |
Preferred Availability | false | Repairable | REPAIRABLE |
Metal parts construction | Plated brass, copper or painted steel | Control modules construction | Thermoset and thermoplastic moldings |
Enclosure | Open type | Number of poles | 3 |
Line/load side power terminals | Two M12 x 1.75 diam holes per power pole | Control terminals | ClAing yoke connection, M3 screw clA |
Power terminal markings | NEMA, CENELEC EN50 012 | Function | Single direction |
Internal bypass | Yes | Break | 360VA for auxiliary contacts |
Make | 3600VA for auxiliary contacts | Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement |
Power pole construction | Heatsink hockey puck thyristor modular design | Height | 600 mm (23.62 in) |
Depth | 276.5 mm (10.89 in) | Width | 290 mm (11.42 in) |
Shock | Opsal: 5.5 G | Weight | 44.928 |
Pollution degree | 2 | Altitude | 2000 m |
EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 | EMC emission levels | Radiated emission: Class A |
Protection against electrical shock | IP2X (with terminal covers) per IEC for power circuit | Operating temperature | Open: -5 to 50 °C (23 to 122 °F) |
Humidity | 5...95% (noncondensing) | Storage and transportation temperature | -20 |
Steady state heat dissipation with control and fan power | 290 W | Contact type | Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4) |
Input ON-state current | 20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit | Rated operational current | 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts |
Input ON-state voltage, min | 85V AC @ 19.2V DC/20.4V AC for control circuit | Input OFF-state voltage, max | 50V AC @ 10V DC/12V AC for control circuit |
Reset resistance | 1600 ? ± 100 ? for PTC input ratings | Response resistance | 3400 ? ± 150 ? for PTC input ratings |
Short circuit trip resistance | 25 ? ± 10 ? for PTC input ratings | Allen bradley power supply control module, min | 1606-XLP50E @ 24V DC (-15%, +10%) |
Tachometer input | 0...5V DC @ 4.5V DC = 100% Speed | Cold resistance of PTC sensor chain, max | 1500 ? for PTC input ratings |
Transient time control module | 500 ms @ 24V DC (-15%, +10%) | Inrush time control module | 250 ms @ 24V DC (-15%, +10%) |
Response time | 800 ms for PTC input ratings | Voltage at PTC terminals (RPTC = 4 kΩ), max | <7.5 for PTC input ratings |
Steady state watts control module | 24 W @ 24V DC (-15%, +10%) | Transient watts control module | 60 W @ 24V DC (-15%, +10%) |
Voltage at PTC terminals (RPTC = open), max | 30V for PTC input ratings | Inrush current control module | 5A @ 24V DC (-15%, +10%) |
Number of sensors, max | 6 for PTC input ratings | Short circuit protection device performance (SCPD) type | Type 1 |
Integrated motor overload protection | Yes | Rated control supply voltage at DC | 24 V |
Optional controller feature | SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motorâs full-load current rating | Standard available fault current, max | 70kA @ 690V for maximum FLC |
Standard controller feature | Status indication: stopped, starting, stopping, at speed, alarm and fault | Utilization category | MG 1 per UL/CSA/NEMA for power circuit |
Type of contacts | Progmable NO/NC for auxiliary contacts | Type of control circuit | Electromagnetic relay for auxiliary contacts |
Conventional thermal current (Ith) | AC/DC: 5 A for auxiliary contacts | Type of current | AC for auxiliary contacts |
High capacity available fault current, max | 69kA @ 600V, maximum current 800 A time delay Class J or Class L fuse for line connected motors | Number of contacts | 1 for auxiliary contacts |
Short-circuit protection device list | Standard fuse, circuit breaker and high capacity time delay class CC/J/L | Input OFF-state current | <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage |
Rated operational voltage | 200...480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit | Insulation voltage | Rated 500V per IEC for power circuit |
Transient protection | Metal oxide varistors: 220 J (optional) for power circuit | Ampere tested north american style, max | A070D33xxx1250 A100URD73xxx1250 @ 690V for maximum FLC |
Ampere tested european style, max | 9 URD 73xxx1250 6,6URD33xxx1250 @ 690V for maximum FLC | Delta connected motor current | 277...831A @ 500/575V AC, 3-phase |
Line connected motor current | 160...480 A @ 600/Y/690V AC, 3-phase | Dielectric withstand | 2500V per IEC for power circuit |
Rated impulse voltage | 6000V per IEC for power circuit | Delta connected motor power, max | 900Hp @ 575V AC, 60 Hz, 3-phase |
Line connected motor power, max | 600Hp @ 600V AC, 60 Hz, 3-phase | Operating frequency | 50/60 Hz for power circuit |
Repetitive peak inverse voltage rating | 1400V per UL/CSA/NEMA for power circuit | DV/DT protection | RC snubber network for power circuit |
Heatsink fan rating | 60VA @ 110/120V AC or 220/240V AC | Transformer control module | 75VA @ 100...240V AC (-15%, +10%) |
Trip current rating | 117% of motor FLC | Trip classes | 10, 15, 20 and 30 |
Control options | Brake control | Controller type | Soft starter |
Overload current for delta connected devices | 277 A | Overload current for line connected devices | 160 A |
Rated control supply voltage at AC 60 Hz | 24 V | Rated control supply voltage at AC 50 Hz | 24 V |
Rated operating voltage Ue | 200 | Voltage type for actuating | AC/DC |
With display | Yes | Product Family | SMC Flex |
Control Voltage | 24V AC/DC |
Specifications may be subject to change without notice