Product Model
150-F970NCA

Selling Points
- 11. Robust Performance: The Allen-Bradley 150-F970NCA SMC-Flex Solid State Controller is designed to handle demanding applications with its robust performance, ensuring reliable operation under high loads.;
- 22. High Power Handling: With a controller rating of 970 A and supporting up to 800 Hp at 460V AC, this controller is perfect for high-power applications that require precise control.;
- 33. Versatile Voltage Range: The controller operates with a 3-phase configuration and accommodates input voltages of 200-575V AC, making it versatile for various industrial settings.;
- 44. Open Enclosure Design: The open enclosure design of the 150-F970NCA provides easy access for maintenance and installation, ensuring minimal downtime and maximum efficiency.;
- 55. Comprehensive Warranty: All products, including new, refurbished, and repairs, are covered by the Industrial Automation Company's 2-year warranty, providing peace of mind for your investment.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Weight Unit | KG | Stock Status | NON_STOCKED |
Dimension Length | 0.0 | Dimension Width | 0.0 |
Lead Time | 20 | Dimension Height | 0.0 |
Quick Turnaround | false | Preferred Availability | false |
Repairable | REPAIRABLE | Metal parts construction | Plated brass, copper or painted steel |
Control modules construction | Thermoset and thermoplastic moldings | Enclosure | Open type |
Number of poles | 3 | Line/load side power terminals | Two 13.5 mm (0.53 in) diam holes per power pole |
Control terminals | ClAing yoke connection, M3 screw clA | Power terminal markings | NEMA, CENELEC EN50 012 |
Function | Single direction | Internal bypass | Yes |
Break | 360VA for auxiliary contacts | Make | 3600VA for auxiliary contacts |
Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement | Power pole construction | Heatsink hockey puck thyristor modular design |
Height | 1041.1 mm (41 in) | Depth | 346.2 mm (13.63 in) |
Width | 596.9 mm (23.50 in) | Shock | Opsal: 4 G |
Weight | 185.917 | Pollution degree | 2 |
Altitude | 2000 m | EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 |
EMC emission levels | Radiated emission: Class A | Protection against electrical shock | IP00 (open device) per IEC for power circuit |
Operating temperature | Open: -5 to 50 °C (23 to 122 °F) | Humidity | 5...95% (noncondensing) |
Storage and transportation temperature | -20 | Steady state heat dissipation with control and fan power | 812 W |
Contact type | Auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4) | Input ON-state current | 20mA @ 120V AC/40mA @ 240V AC, 7.6mA @ 24V AC/DC for control circuit |
Rated operational current | 3A @ 120V AC, 1.5A @ 240V AC for auxiliary contacts | Input ON-state voltage, min | 85V AC @ 19.2V DC/20.4V AC for control circuit |
Input OFF-state voltage, max | 50V AC @ 10V DC/12V AC for control circuit | Reset resistance | 1600 ? ± 100 ? for PTC input ratings |
Response resistance | 3400 ? ± 150 ? for PTC input ratings | Short circuit trip resistance | 25 ? ± 10 ? for PTC input ratings |
Tachometer input | 0...5V DC @ 4.5V DC = 100% Speed | Cold resistance of PTC sensor chain, max | 1500 ? for PTC input ratings |
Response time | 800 ms for PTC input ratings | Transformer rating control module | 751 VA (recommended 800 VA) |
Voltage at PTC terminals (RPTC = 4 kΩ), max | <7.5 for PTC input ratings | Voltage at PTC terminals (RPTC = open), max | 30V for PTC input ratings |
Number of sensors, max | 6 for PTC input ratings | Short circuit protection device performance (SCPD) type | Type 1 |
Integrated motor overload protection | Yes | Optional controller feature | SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motorâs full-load current rating |
Standard available fault current, max | 85kA @ 690V for maximum FLC | Standard controller feature | Status indication: stopped, starting, stopping, at speed, alarm and fault |
Utilization category | MG 1 per UL/CSA/NEMA for power circuit | Type of contacts | Progmable NO/NC for auxiliary contacts |
Type of control circuit | Electromagnetic relay for auxiliary contacts | Conventional thermal current (Ith) | AC/DC: 5 A for auxiliary contacts |
Type of current | AC for auxiliary contacts | High capacity available fault current, max | 85kA @ 600V, maximum current 3000 A time delay Class J or Class L fuse for inside delta connected motors |
Number of contacts | 1 for auxiliary contacts | Short-circuit protection device list | Standard fuse, circuit breaker and high capacity time delay class CC/J/L |
Input OFF-state current | <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage | Rated operational voltage | 200...600V AC (-15%, +10%) per UL/CSA/NEMA for power circuit |
Insulation voltage | Rated 500V per IEC for power circuit | Transient protection | Metal oxide varistors: 220 J (optional) for power circuit |
Ampere tested north american style, max | Two fuses in parallel A070URD33xxx1250 @ 690V for maximum FLC | Ampere tested european style, max | Two fuses in parallel 6,6URD33xxx1250 @ 690V for maximum FLC |
Delta connected motor current | 400...1200A @ 500/575V AC, 3-phase | Line connected motor current | 323...970 A @ 600/Y/690V AC, 3-phase |
Dielectric withstand | 2500V per IEC for power circuit | Rated impulse voltage | 6000V per IEC for power circuit |
Delta connected motor power, max | 800 kW @ 500V AC @ 50Hz, 3-phase | Line connected motor power, max | 800Hp @ 460V AC, 60 Hz, 3-phase |
Operating frequency | 50/60 Hz for power circuit | Repetitive peak inverse voltage rating | 1600V per UL/CSA/NEMA for power circuit |
DV/DT protection | RC snubber network for power circuit | Heatsink fan rating | 150VA @ 110/120V AC or 220/240V AC |
Trip current rating | 117% of motor FLC | Trip classes | 10, 15, 20 and 30 |
Control options | None | Controller type | Soft starter |
Overload current for delta connected devices | 400 A | Overload current for line connected devices | 323 A |
Rated control supply voltage at AC 60 Hz | 230 V | Rated control supply voltage at AC 50 Hz | 230 V |
Rated operating voltage Ue | 200 | Voltage type for actuating | AC |
With display | Yes | Controller Rating | 970 A 800Hp @ 460V AC |
Control Voltage | 230...240V AC |
Specifications may be subject to change without notice