Product Model
1606-XLE120E

Selling Points
- 11. High Efficiency: The 1606-XLE120E boasts a typical efficiency of 94.3%, ensuring minimal power losses and optimal performance in industrial environments.;
- 22. Adjustable Output Voltage: With an adjustable output voltage range of 24V, this power supply can be tailored to meet specific application requirements, providing flexibility and versatility.;
- 33. Robust Design: Designed to withstand rigorous industrial conditions, the 1606-XLE120E features a robust build with a power reserve of 20% and a derating of 3W/°C, ensuring reliable operation even under stress.;
- 44. Active Inrush Current Limiting: Equipped with an active inrush current limiter, this power supply protects against high startup currents, extending the lifespan of connected equipment and reducing the risk of damage.;
- 55. Dynamic Power Boost: The 1606-XLE120E offers a dynamic 120% power boost under 45°C, providing additional power when needed, making it suitable for applications requiring temporary increased power demands.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | STOCKED | Dimension Length | 15.24 |
Dimension Width | 13.97 | Lead Time | 5 |
Dimension Height | 6.033 | Quick Turnaround | false |
Preferred Availability | true | Repairable | NOT_REPAIRABLE |
Weight | 0.542 | Relative humidity | 5 to 95 % |
Lifetime, min | 166 kh (+40 °C) | Storage temperature | -25 °C |
Operating temperature | -25 °C | Ripple and noise, max | 50 mV |
Vibration | 2 g | Wall mounting possible | Yes |
MTBF | 867 kh (40 °C, SN29500) | Shock | 30 G, 6ms 20 G, 11ms |
Type of electric connection | Screw connection | Degree of protection (IP) | IP20 |
Width | 32 mm | Direct mounting possible | No |
Depth | 102 mm | Height | 124 mm |
Stabilized | Yes | Rail mounting possible | Yes |
Output voltage stabilized | Yes | Rated input current | 2.6A @ 100V AC |
Special family function | Dynamic 120% power boost under 45C Degree | Input inrush current | 4 A/3 A |
Efficiency | 94.3% typical | Hold-up time | >80 ms @ 120V |
Sub group | Essential line | Power losses | 7.3 W typical |
External input fuse, min | B-6 A or C-6 A | Rated output current | 5A @ 24V |
Operational range | 90â¦132V AC | Power factor | 0.91 typical |
Adjustment range | 24 V | Input inrush current limiter | Active |
DC OK relay contact | Yes | Derating | 3 w/°c |
Power reserves | 20 % | Rated supply voltage at DC | 110 V |
Rated supply voltage at AC 60 Hz | 100 V | Rated supply voltage at AC 50 Hz | 100 V |
1st secondary output voltage | 24 V | Voltage type of supply voltage | AC/DC |
Power output | 120 W | Nominal value output current 1 | 5 A |
Max. output current 1 | 5 A | Secondary voltage adjustable | Yes |
Nominal value output voltage 1 | 24 V |
Specifications may be subject to change without notice