  • 11. High Efficiency: The 1606-XLE120E boasts a typical efficiency of 94.3%, ensuring minimal power losses and optimal performance in industrial environments.;
  • 22. Adjustable Output Voltage: With an adjustable output voltage range of 24V, this power supply can be tailored to meet specific application requirements, providing flexibility and versatility.;
  • 33. Robust Design: Designed to withstand rigorous industrial conditions, the 1606-XLE120E features a robust build with a power reserve of 20% and a derating of 3W/°C, ensuring reliable operation even under stress.;
  • 44. Active Inrush Current Limiting: Equipped with an active inrush current limiter, this power supply protects against high startup currents, extending the lifespan of connected equipment and reducing the risk of damage.;
  • 55. Dynamic Power Boost: The 1606-XLE120E offers a dynamic 120% power boost under 45°C, providing additional power when needed, making it suitable for applications requiring temporary increased power demands.
Product Details
1606-XLE120E
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
STOCKED
Dimension Length
15.24
Dimension Width
13.97
Lead Time
5
Dimension Height
6.033
Quick Turnaround
false
Preferred Availability
true
Repairable
NOT_REPAIRABLE
Weight
0.542
Relative humidity
5 to 95 %
Lifetime, min
166 kh (+40 °C)
Storage temperature
-25 °C
Operating temperature
-25 °C
Ripple and noise, max
50 mV
Vibration
2 g
Wall mounting possible
Yes
MTBF
867 kh (40 °C, SN29500)
Shock
30 G, 6ms 20 G, 11ms
Type of electric connection
Screw connection
Degree of protection (IP)
IP20
Width
32 mm
Direct mounting possible
No
Depth
102 mm
Height
124 mm
Stabilized
Yes
Rail mounting possible
Yes
Output voltage stabilized
Yes
Rated input current
2.6A @ 100V AC
Special family function
Dynamic 120% power boost under 45C Degree
Input inrush current
4 A/3 A
Efficiency
94.3% typical
Hold-up time
>80 ms @ 120V
Sub group
Essential line
Power losses
7.3 W typical
External input fuse, min
B-6 A or C-6 A
Rated output current
5A @ 24V
Operational range
90…132V AC
Power factor
0.91 typical
Adjustment range
24 V
Input inrush current limiter
Active
DC OK relay contact
Yes
Derating
3 w/°c
Power reserves
20 %
Rated supply voltage at DC
110 V
Rated supply voltage at AC 60 Hz
100 V
Rated supply voltage at AC 50 Hz
100 V
1st secondary output voltage
24 V
Voltage type of supply voltage
AC/DC
Power output
120 W
Nominal value output current 1
5 A
Max. output current 1
5 A
Secondary voltage adjustable
Yes
Nominal value output voltage 1
24 V

Specifications may be subject to change without notice