Product Model
1606-XLE120E-2

Selling Points
- 11. High Efficiency: The Allen Bradley 1606-XLE120E-2 power supply boasts an efficiency of up to 90.4%, ensuring minimal energy loss and maximizing power output. This makes it an excellent choice for applications where energy efficiency is crucial.;
- 22. Compact Design: With its ultra-slim design, the 1606-XLE120E-2 fits seamlessly into any industrial setup. Its compact size also reduces installation space requirements, making it easier to integrate into existing systems.;
- 33. Wide Operational Temperature Range: This power supply operates effectively within a wide temperature range of -25°C to +70°C, ensuring reliable performance even in harsh industrial environments.;
- 44. Low Inrush Current: The 1606-XLE120E-2 features an electronic inrush current limitation, which prevents sudden spikes in current during startup. This reduces stress on the system and prolongs the lifespan of the power supply.;
- 55. DIN Rail Mounting: Designed for easy installation, the 1606-XLE120E-2 can be mounted directly onto a DIN rail, simplifying the setup process and saving time. This makes it an excellent choice for applications where quick deployment is essential.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | STOCKED | Dimension Length | 15.189 |
Dimension Width | 14.3 | Lead Time | 5 |
Dimension Height | 6.299 | Quick Turnaround | false |
Preferred Availability | true | Repairable | NOT_REPAIRABLE |
Weight | 0.585 | Lifetime, min | 92 kh (+40 °C) |
Operating temperature | -25 °C | Ripple and noise, max | 50 mV |
Wall mounting possible | Yes | MTBF | 1173 kh (+40 °C, SN29500) |
Type of electric connection | Screw connection | Degree of protection (IP) | IP20 |
Width | 40 mm | Direct mounting possible | No |
Depth | 117 mm | Height | 124 mm |
Stabilized | Yes | Rail mounting possible | Yes |
Output voltage stabilized | Yes | Input inrush current | 4 A/4 A |
Efficiency | 90.4 % typical | Derating | 3 W/°C |
Power losses | 12.7 W typical | External input fuse, min | B-6 A or C-3 A |
Output current range | 5 to 4.3 A | Power factor | 0.45 typical |
Input inrush current limiter | Active | Power reserves | 20 % |
Rated supply voltage at AC 60 Hz | 380 V | Rated supply voltage at AC 50 Hz | 380 V |
1st secondary output voltage | 24 V | Voltage type of supply voltage | AC |
Power output | 120 W | Nominal value output current 1 | 5 A |
Max. output current 1 | 5 A | Secondary voltage adjustable | Yes |
Nominal value output voltage 1 | 24 V | Input Circuit Protection | 6 A Slow Blow Fuse or?Cat. No. 1489-A3C060 |
Specifications may be subject to change without notice