Rockwell Automation 1606-XLE120EH

Selling Points

  • 11. High Efficiency The Allen Bradley 1606-XLE120EH operates at a high efficiency of 91.3%, minimizing heat output and reducing associated running costs, making it an economical choice for industrial power supply needs.;
  • 22. Low Inrush Current Equipped with an active inrush limitation circuitry, this power supply limits the input inrush current after turn-on, reducing stress on the system and prolonging its lifespan.;
  • 33. Robust Protection Features The 1606-XLE120EH is electronically protected against overload, no-load, and short-circuits. It also features output over-voltage protection, ensuring the system remains safe and functional under various operating conditions.;
  • 44. Compact Design With a compact footprint, this power supply maximizes usable space in the panel, making it ideal for applications where space is limited. It is also convection cooled, eliminating the need for forced cooling.;
  • 55. Wide Temperature Range The 1606-XLE120EH operates within a wide temperature range of 0°C to +70°C, ensuring reliable performance in various environmental conditions. It also has a power reserve of 20%, which can be used continuously at temperatures up to +45°C.
Product Details
1606-XLE120EH
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
15.24
Dimension Width
14.288
Lead Time
55
Dimension Height
6.35
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Weight
0.544
Lifetime, min
166 kh (+40 °C)
Operating temperature
-25 °C
Ripple and noise, max
50 mV
Wall mounting possible
Yes
MTBF
867 kh (+40 °C, SN29500)
Degree of protection (IP)
IP20
Width
32 mm
Direct mounting possible
No
Depth
102 mm
Height
124 mm
Stabilized
Yes
Rail mounting possible
Yes
Output voltage stabilized
Yes
Input inrush current
4 A/3 A
Efficiency
94.3 % typical
Derating
3 W/°C
Power losses
7.3 W typical
External input fuse, min
B-6A or C-6 A
Output current range
5 to 4.3 A
Power factor
0.91 typical
Connection terminals
Push-in
Input inrush current limiter
Active
DC OK relay contact
Yes
Power reserves
20 %
Rated supply voltage at DC
110 V
Rated supply voltage at AC 60 Hz
100 V
Rated supply voltage at AC 50 Hz
100 V
1st secondary output voltage
24 V
Voltage type of supply voltage
AC/DC
Power output
120 W
Nominal value output current 1
5 A
Max. output current 1
5 A
Secondary voltage adjustable
Yes
Nominal value output voltage 1
24 V

Specifications may be subject to change without notice