Rockwell Automation 1606-XLE240ECRZ

Selling Points

  • 11. Redundant Design for Reliability: The 1606-XLE240ECRZ features a redundant design, ensuring continuous operation even in case of a single unit failure. This makes it ideal for critical applications where downtime is not acceptable.;
  • 22. Hot-Swap Capability: With hot-swap capability, the power supply can be replaced without shutting down the system, reducing downtime and increasing overall system availability.;
  • 33. High Efficiency: The 1606-XLE240ECRZ operates at a high efficiency rate of 94.7%, minimizing heat generation and reducing the need for cooling systems, which in turn saves energy and extends the lifespan of the power supply.;
  • 44. Robust Design and Durability: Built with robust materials and designed to withstand harsh industrial environments, the 1606-XLE240ECRZ ensures reliable operation over a wide temperature range (-25°C to +70°C).;
  • 55. Easy Installation and Maintenance: The power supply is designed for easy installation on DIN rails, making it simple to integrate into existing systems. Additionally, its compact size (124 mm height, 117 mm depth, and 39 mm width) saves space in control panels, and its plug-in connection simplifies maintenance tasks.
Product Details
1606-XLE240ECRZ
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
15.24
Dimension Width
14.542
Lead Time
64
Dimension Height
9.271
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Weight
0.739
Lifetime, min
109 kh (+40 °C)
Operating temperature
-25 °C
Ripple and noise, max
50 mV
Wall mounting possible
Yes
MTBF
641 kh (+40 °C, SN29500)
Type of electric connection
Plug-in connection
Degree of protection (IP)
IP20
Width
39 mm
Direct mounting possible
No
Depth
117 mm
Height
124 mm
Adjustment range
Fixed
Stabilized
Yes
Rail mounting possible
Yes
Output voltage stabilized
Yes
Input inrush current
6 A/9 A
Efficiency
94.7 % typical
Derating
6 W/°C
Power losses
13.4 W typical
External input fuse, min
B-6 A or C-6 A
Power factor
0.97 typical
Input inrush current limiter
Active
Hot-swap
Yes
DC OK relay contact
Yes
Power reserves
20 %
Rated supply voltage at DC
110 V
Rated supply voltage at AC 60 Hz
100 V
Rated supply voltage at AC 50 Hz
100 V
Voltage type of supply voltage
AC/DC
Power output
240 W
Nominal value output current 1
10 A
Secondary voltage adjustable
No
Nominal value output voltage 1
24 V

Specifications may be subject to change without notice