Rockwell Automation 2080-OW4I

Selling Points

  • 11. Reliable Operation: The Allen Bradley 2080-OW4I ensures reliable operation with its individually isolated digital outputs, minimizing the risk of electrical interference.;
  • 22. Compact Design: The module's compact size makes it easy to integrate into existing systems, saving space and improving overall system efficiency.;
  • 33. Robust Performance: Designed for industrial applications, this module delivers robust performance under various operating conditions, including extreme temperatures and vibrations.;
  • 44. Easy Integration: Compatible with all Micro800 CPUs, the 2080-OW4I is easy to integrate into your existing control systems, reducing setup time and complexity.;
  • 55. High-Quality Relays: Equipped with high-quality relays, this module provides consistent and precise control, ensuring that your operations run smoothly and efficiently.
Product Details
2080-OW4I
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Weight
0.034
Stock Status
STOCKED
Dimension Length
9.27
Dimension Width
6.86
Lead Time
5
Dimension Height
3.56
Quick Turnaround
false
Preferred Availability
true
Repairable
NOT_REPAIRABLE
Explosion safety category for dust
None
Explosion safety category for gas
None
Mounting torque
0.2 nm
Vibration
2.0 G @ 10…500 Hz
Shock
Operating: 10 g
Terminal base screw torque, max
0.19 Nm (1.7 in-lb.), using a 2.5 mm
Enclosure type rating
None (open-style)
Nonoperating temperature
40 to 85 °C
Operating temperature
-20 to 65 °C
Relative humidity
5...95% noncondensing
North American temperature code
T4
Surrounding air temperature, max
65 °C
Output current, inductive
1.0 A steady state @ 5...28V DC @ 0.93A steady state @ 30V DC @ 0.5A steady state @ 48V DC @ 0.22A steady state @ 125V DC @ 2.0A steady state, 15 A make @ 125V AC, PF - cos θ = 0.4, 2.0 A steady state, 7.5 A make @ 240V AC, PF - cos θ = 0.4
Output power, resistive, max
250VA for 125V AC resistive loads, 480VA for 240V AC resistive loads, 60VA for 30V DC resistive loads, 24VA for 48V DC resistive loads, 27.5VA for 125V DC resistive loads
Output current, resistive
2A @ 5...30V DC, 0.5A @ 48V DC, 0.22A @ 125V DC, 2A @ 125V AC, 2A @ 240V AC
Inrush current
<120mA @ 3.3V, <120mA @ 24V
Backplane power
3.3V DC @ 38mA
Wire type
Copper
Initial contact resistance of relay, max
30 mohm
Minimum load per point
10 mA
SIL according to IEC 61508
None
Redundancy
No
Isolation voltage
240V (continuous), reinforce insulation type, between output channels and output channels to backplane type tested for 60 s @ 1480V AC Outputs to Outputs, Outputs to Backplane
Wire size
0.05...1.31 mm2 (30...16 AWG) solid copper wire rated @ 90 °C (194 °F ) insulation maximum
Insulation stripping length
5 mm
Pilot duty rating
C300, R150
Relay contact, break
28VA @ 24V DC maximum volts, 0.35 power factor
Relay contact, make
7.5A @ 240V AC maximum volts, 0.35 power factor
Relay contact, continuous
2.0A @ 120V AC maximum volts, 0.35 power factor
Number of I/O
4-channel relay output
Wiring category
2 - on signal ports, 2 - on power ports
Output delay time, max
OFF to ON: 10 ms, ON to OFF: 10 ms
Status indicator
4 yellow
Type of electric connection
Screw connection
Type of digital output
Relay
Type of output voltage
DC
Type of voltage (input voltage)
DC
Digital outputs configurable
No
Digital inputs configurable
No
I/O Status Indication
LED
I/O Isolation
Isolated

Specifications may be subject to change without notice