Selling Points

  • 1Ensures safe operation in hazardous environments with CE II1 G/D-EEx ia IIC marking.
  • 2Provides accurate signal detection and processing with an accuracy drift of <= 70 ppm/°C.
  • 3Weighs just 0.66 lb (0.3 kg), making it easy to install and integrate into existing systems.
  • 4Minimizes energy consumption with a power dissipation of 2W, suitable for environmentally conscious industries.
  • 5Equipped with a switching frequency of 100Hz, ensuring rapid data acquisition and processing for time-critical applications.
Product Details
140AIO33000C
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon Quantum automation platform
Product or Component Type
Intrinsically safe analog output module
Software Designation
Unity Pro<br />Concept V2.2 and above<br />ProWORX
Product destination
In conjunction with products for zone 20, 21 or 22
Analogue output number
8
Analogue output range
0...20 mA 0 to 20000 points<br />0...25 mA 0 to 25000 points<br />4...20 mA 15 bits, 0 to 16000 points<br />4...20 mA 15 bits, 0 to 4095 points
Maximum loop resistance
500 Ohm
Absolute accuracy error
+/- 0.2 % of full scale 77 °F (25 °C)
Accuracy drift according to temperature
<= 70 ppm/°C<br />40 ppm/°C
Linearity
+/- 1 LSB
Update time
4 ms
Setting time
1 ms to +/- 0.1 % of the final value
Isolation between channels and bus
1780 Vrms 60 s AC
Fault type
Open circuit 4...20 mA
Power dissipation in W
12.5 W
Hot swapping fallback
Not allowed per intrinsic safety standards
Protection Type
Internal fuse
marking
CE<br />II1 G/D-EEx ia IIC
Bus current requirement
2.5 A
Module format
Standard
Net Weight
0.7 lb(US) (0.3 kg)
Protective treatment
Conformal coating Humiseal 1A33
Standards
UL 508<br />EN 50281-1-1<br />EN 50020<br />EN 50014<br />CSA C22.2 No 142<br />EN 50039<br />Directive ATEX 94/9/EC<br />EN 50284
Dust zone
Outside zone
Product Certifications
hazardous location class 1, division 1 groups A, B, C<br />C-Tick.1<br />FM Class 1 Division 2<br />SIRA 02ATEX2345X
Resistance to electrostatic discharge
4 kV contact IEC 801-2<br />8 kV on air IEC 801-2
Resistance to electromagnetic fields
9.1 V/m (10 V/m) 80…2000 MHz IEC 801-3
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Relative Humidity
95 % without condensation
Operating altitude
<= 16404.2 ft (5000 m)

Specifications may be subject to change without notice