Product Model

140DAO84000

In Stock
Last updated: 2025/4/26
schneider 140DAO84000

Selling Points

  • 1Control each channel independently with 16 isolated discrete outputs.
  • 2Handles brief voltage spikes up to 400 Vrms for a single cycle.
  • 3Minimal voltage drop of 1.5 V and low off-state leakage currents.
  • 416 green LEDs for input status and one red LED for external faults.
  • 5Operates within 47 to 63 Hz supply frequency range and supports 20 to 253 V AC outputs.
Product Details
140DAO84000
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon Quantum automation platform
Product or Component Type
AC discrete output modules
Discrete output number
16
Discrete output type
Isolated
Group of channels
16 groups of 1 channel
Supply frequency
47...63 Hz
Maximum voltage drop
1.5 V
Discrete output voltage
20...253 V AC
Addressing requirement
1 output word
Absolute maximum output
300 Vrms 10 s AC<br />400 Vrms 1 cycle AC
Maximum load current
1 mA rms 24 Vrms off state leakage per output<br />1 mA rms 48 Vrms off state leakage per output<br />2 mA rms 115 Vrms off state leakage per output<br />2.5 mA rms 230 Vrms off state leakage per output<br />3 A rms 200...230 V per output<br />4 A rms 24...115 V per output<br />16 A rms per module<br />4 A rms sum of four points, continuous
Surge current
10 A during 3 cycles per point<br />20 A during 2 cycles per point<br />30 A during 1 cycle per point
DV/dt
400 V/ms
Response Time
<= 0.5 ms at state 0 to state 1<br /><= 0.5 ms at state 1 to state 0
Protection Type
Internal by RC filter
Power dissipation
1.85 + (1.1 V x total module load current)
Associated fuse rating
5 A
marking
CE
Local signalling
for bus communication is present (Active) 1 LED (green)<br /> for external fault detected (F) 1 LED (red)<br /> for input status 16 LEDs (green)
Bus current requirement
350 mA
Module format
Standard
Net Weight
1.069 lb(US) (0.485 kg)
Product Certifications
cUL<br />FM Class 1 Division 2
Standards
UL 508<br />CSA C22.2 No 142
Electromagnetic compatibility
Electrostatic discharge immunity test - test level: 4 kV (contact discharge) conforming to IEC 801-2<br />Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 801-2<br />Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 801-3
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Relative Humidity
95 % without condensation
Operating altitude
<= 16404.2 ft (5000 m)

Specifications may be subject to change without notice