Selling Points

  • 1High Channel Density: 32 discrete outputs in 4 groups of 8 channels for efficient control.
  • 2Wide Voltage Range: Supports 20-253V AC discrete output voltage for versatile applications.
  • 3Fast Response Time: ≤0.5 ms switching time for quick and reliable operation.
  • 4Internal Protection: Equipped with internal output protection by 4A fuse and RC filter for safety.
  • 5Galvanic Isolation: Provides galvanic isolation between channels and power supply for enhanced reliability.
Product Details
140DAO85300C
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Modicon Quantum automation platform
Product or Component Type
AC discrete output modules
Discrete output number
32
Group of channels
4 groups of 8 channels
Supply frequency
47...63 Hz
Maximum voltage drop
1.5 V
Discrete output voltage
20...253 V AC
Addressing requirement
2 output words
Absolute maximum output
300 Vrms 10 s AC<br />400 Vrms 1 cycle AC
Maximum load current
16 A rms per module<br />4 A rms per group<br />0.88 mA 230 V off state leakage per output<br />1 A rms 20...253 V per output
Surge current
2.5 A 1 ms
DV/dt
400 V/ms
Response Time
<= 0.5 ms at state 0 to state 1<br /><= 0.5 ms at state 1 to state 0
Protection Type
Internal output protection by 4 A fuse<br />Internal by RC filter
Power dissipation
1.60 + (1.0 V x total module load current)
marking
CE
Local signalling
for bus communication is present (Active) 1 LED (green)<br /> for external fault detected (F) 1 LED (red)<br /> for input status 32 LEDs (green)
Bus current requirement
320 mA
Module format
Standard
Net Weight
0.99 lb(US) (0.45 kg)
Protective treatment
Conformal coating Humiseal 1A33
Product Certifications
cUL<br />FM Class 1 Division 2
Standards
UL 508<br />CSA C22.2 No 142
Electromagnetic compatibility
Electrostatic discharge immunity test - test level: 4 kV (contact discharge) conforming to IEC 801-2<br />Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 801-2<br />Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 801-3
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Relative Humidity
95 % without condensation
Operating altitude
<= 16404.2 ft (5000 m)

Specifications may be subject to change without notice