Product Model
ATS480M10Y

Selling Points
- 1High Performance and Reliability: Handles demanding electrical loads with seamless transitions.
- 2User-Friendly Interface: Intuitive design for easy operation, even for non-experts.
- 3Compact Design: Fits into tight spaces without compromising performance or reliability.
- 4Advanced Safety Features: Protects devices and connected systems from electrical faults and overloads.
- 5Enhanced Operational Efficiency: Maintains consistent operations, reducing downtime and improving productivity.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altivar Soft Starter ATS480 | Product or Component Type | Soft starter |
Product destination | Asynchronous motors | Product Specific Application | Process and infrastructures |
Device short name | ATS480 | Phase | 3 phase |
Utilisation category | AC-3A<br />AC-53A | Ue power supply voltage | 208...690 V - 15...10 % |
power supply frequency | 50...60 Hz - 20...20 % | [Ie] rated operational current | Normal duty 1000.0 A 104 °F (40 °C)) |
rated current in heavy duty | 790.0 A at 104 °F (40 °C) heavy duty | Torque control | True |
IP Degree of Protection | IP00 | Motor power kW | 250.0 kW 230 V in the motor supply line normal duty<br />220.0 kW 230 V in the motor supply line heavy duty<br />500.0 kW 400 V in the motor supply line normal duty<br />400.0 kW 400 V in the motor supply line heavy duty<br />630.0 kW 440 V in the motor supply line normal duty<br />500.0 kW 440 V in the motor supply line heavy duty<br />630.0 kW 500 V in the motor supply line normal duty<br />500.0 kW 500 V in the motor supply line heavy duty<br />630.0 kW 525 V in the motor supply line normal duty<br />500.0 kW 525 V in the motor supply line heavy duty<br />900.0 kW 660 V in the motor supply line normal duty<br />710.0 kW 660 V in the motor supply line heavy duty<br />900.0 kW 690 V in the motor supply line normal duty<br />710.0 kW 690 V in the motor supply line heavy duty<br />355.0 kW 230 V to the motor delta terminals heavy duty<br />710.0 kW 400 V to the motor delta terminals normal duty<br />630.0 kW 400 V to the motor delta terminals heavy duty |
Maximum Horse Power Rating | 350.0 hp 208 V normal duty<br />250.0 hp 208 V heavy duty<br />350.0 hp 230 V normal duty<br />300.0 hp 230 V heavy duty<br />800.0 hp 460 V normal duty<br />600.0 hp 460 V heavy duty<br />1000.0 hp 575 V normal duty<br />800.0 hp 575 V heavy duty | Option card | Communication module Profibus DP V1<br />Communication module Modbus TCP/EtherNet/IP<br />Communication module CANopen daisy chain<br />Communication module CANopen Sub-D<br />Communication module CANopen open style |
Device connection | In the motor supply line<br />To the motor delta terminals | [Us] control circuit voltage | 110...230 V AC 50/60 Hz - 15...10 % |
Apparent power | 0.2 kVA | Integrated motor overload protection | True |
motor thermal protection class | Class 10E | Protection type | Phase failure line<br />Integrated thermal protection motor<br />Thermal protection starter<br />Current overload motor<br />Underload motor<br />Excessive starting time, locked rotor motor<br />Motor phase loss motor<br />Line supply phase loss line<br />Line supply phase loss motor<br />Thermal protection motor |
current limiting %In (5 x Ie maximum) | 150…700 % | [In] Rated current pwr loss specifctn | 1000.0 A |
Power loss static current independent | 25.0 W | Power loss per device current dependent | 2845.0 W |
Standards | IEC 60947-4-2<br />UL 60947-4-2<br />IEC 60664-1 | Product Certifications | CE<br />cULus<br />CCC<br />UKCA<br />RCM<br />EAC<br />DNV<br />ABS<br />BV<br />CCS |
marking | CE<br />CCC<br />UKCA<br />EAC<br />RCM<br />CULus | [Uc] control circuit voltage | 24 V DC |
Discrete input number | 4 | Discrete input type | STOP) logic inputs, 3500 Ohm<br />RUN) logic inputs, 3500 Ohm<br />DI3) programmable as logic input, 3500 Ohm<br />DI4) programmable as logic input, 3500 Ohm |
Input compatibility | STOP discrete input level 1 PLC IEC 61131-2<br />RUN discrete input level 1 PLC IEC 61131-2<br />DI3 discrete input level 1 PLC IEC 61131-2<br />DI4 discrete input level 1 PLC IEC 61131-2 | Discrete input logic | Programmable digital input < 5 V |
Relay output number | 3 | Relay output type | Relay outputs R1A 1 NO<br />Relay outputs R1B 1 NO<br />Relay outputs RIC NO/NC programmable |
Minimum switching current | 100 mA 12 V DC relay outputs | Maximum switching current | Relay outputs 2 A 250 V AC<br />Relay outputs 2 A 30 V DC<br />Relay outputs |
Discrete output number | 2 | Discrete output type | DQ1) programmable digital output <= 30 V<br />DQ2) programmable digital output <= 30 V |
Output compatibility | Open collector level 1 PLC IEC 65A-68 | Analogue input number | 1 |
Analogue input type | AI1/PTC PTC/Pt 100 temperature probe<br />PTC2 PTC/Pt 100 temperature probe<br />PTC3 PTC/Pt 100 temperature probe | Analogue output number | 1 |
Analogue output type | Current output AQ1 0...20 mA or 0...10 V 500 Ohm | communication port protocol | Modbus serial |
Connector Type | 1 RJ45 | Communication data link | Serial |
Physical interface | 2-wire RS 485 | Transmission Rate | 1200...256000 bit/s |
Transmission frame | RTU | Data format | 8 bits, configurable odd, even or no parity |
Type of polarization | No impedance Modbus serial | Number of addresses | 0…227 Modbus serial |
Method of access | Slave Modbus serial | Function Available | External bypass control<br />Pre-heating<br />Smoke extraction<br />Multi-motor cascade<br />Second motor set<br />User management<br />Ports and services hardening<br />Security event logging<br />Cybersecure firmware update<br />Single direction |
Display screen available | True | Operating position | Vertical +/- 10 degree |
Height | 35.04 in (890.0 mm) | Width | 30.3 in (770.0 mm) |
Depth | 13.0 in (329.0 mm) | Net Weight | 253.5 lb(US) (115.0 kg) |
Electromagnetic compatibility | Conducted and radiated emissions level A IEC 60947-4-2<br />Conducted and radiated emissions with bypass level B IEC 60947-4-2<br />Damped oscillating waves level 3 IEC 61000-4-12<br />Electrostatic discharge level 3 IEC 61000-4-11<br />Immunity to electrical transients level 4 IEC 61000-4-4<br />Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3<br />Voltage/current impulse level 3 IEC 61000-4-5 | Pollution degree | Level 3 |
[Uimp] rated impulse withstand voltage | 6 kV | [Ui] Rated Insulation Voltage | 690 V |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3<br />Class 3S2 according to IEC 60721-3-3 | Relative humidity | 0…95 % without condensation or dripping water IEC 60068-2-3 |
Ambient air temperature for operation | 104…140 °F (40…60 °C) with current derating of 2 % per °C)<br />5…104 °F (-15…40 °C) without derating) | Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Operating altitude | <= 3280.84 ft (1000 m) without derating<br />> 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m | Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
Maximum deflection under vibratory load (during storage) | 1.75 mm at 2...9 Hz | Maximum deflection under vibratory load (during transport) | 1.75 mm at 2...9 Hz |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz | Maximum acceleration under vibratory load (during storage) | 15 m/s² at 200...500 Hz<br />10 m/s² at 9...200 Hz |
Maximum acceleration under vibratory load (during transport) | 15 m/s² at 200...500 Hz<br />10 m/s² at 9...200 Hz | Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under shock load (during storage) | 100 m/s² at 11 ms | Maximum acceleration under shock load (during transport) | 100 m/s² at 11 ms |
Specifications may be subject to change without notice