ATS480M10Y
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altivar Soft Starter ATS480
Product or Component Type
Soft starter
Product destination
Asynchronous motors
Product Specific Application
Process and infrastructures
Device short name
ATS480
Phase
3 phase
Utilisation category
AC-3A<br />AC-53A
Ue power supply voltage
208...690 V - 15...10 %
power supply frequency
50...60 Hz - 20...20 %
[Ie] rated operational current
Normal duty 1000.0 A 104 °F (40 °C))
rated current in heavy duty
790.0 A at 104 °F (40 °C) heavy duty
Torque control
True
IP Degree of Protection
IP00
Motor power kW
250.0 kW 230 V in the motor supply line normal duty<br />220.0 kW 230 V in the motor supply line heavy duty<br />500.0 kW 400 V in the motor supply line normal duty<br />400.0 kW 400 V in the motor supply line heavy duty<br />630.0 kW 440 V in the motor supply line normal duty<br />500.0 kW 440 V in the motor supply line heavy duty<br />630.0 kW 500 V in the motor supply line normal duty<br />500.0 kW 500 V in the motor supply line heavy duty<br />630.0 kW 525 V in the motor supply line normal duty<br />500.0 kW 525 V in the motor supply line heavy duty<br />900.0 kW 660 V in the motor supply line normal duty<br />710.0 kW 660 V in the motor supply line heavy duty<br />900.0 kW 690 V in the motor supply line normal duty<br />710.0 kW 690 V in the motor supply line heavy duty<br />355.0 kW 230 V to the motor delta terminals heavy duty<br />710.0 kW 400 V to the motor delta terminals normal duty<br />630.0 kW 400 V to the motor delta terminals heavy duty
Maximum Horse Power Rating
350.0 hp 208 V normal duty<br />250.0 hp 208 V heavy duty<br />350.0 hp 230 V normal duty<br />300.0 hp 230 V heavy duty<br />800.0 hp 460 V normal duty<br />600.0 hp 460 V heavy duty<br />1000.0 hp 575 V normal duty<br />800.0 hp 575 V heavy duty
Option card
Communication module Profibus DP V1<br />Communication module Modbus TCP/EtherNet/IP<br />Communication module CANopen daisy chain<br />Communication module CANopen Sub-D<br />Communication module CANopen open style
Device connection
In the motor supply line<br />To the motor delta terminals
[Us] control circuit voltage
110...230 V AC 50/60 Hz - 15...10 %
Apparent power
0.2 kVA
Integrated motor overload protection
True
motor thermal protection class
Class 10E
Protection type
Phase failure line<br />Integrated thermal protection motor<br />Thermal protection starter<br />Current overload motor<br />Underload motor<br />Excessive starting time, locked rotor motor<br />Motor phase loss motor<br />Line supply phase loss line<br />Line supply phase loss motor<br />Thermal protection motor
current limiting %In (5 x Ie maximum)
150…700 %
[In] Rated current pwr loss specifctn
1000.0 A
Power loss static current independent
25.0 W
Power loss per device current dependent
2845.0 W
Standards
IEC 60947-4-2<br />UL 60947-4-2<br />IEC 60664-1
Product Certifications
CE<br />cULus<br />CCC<br />UKCA<br />RCM<br />EAC<br />DNV<br />ABS<br />BV<br />CCS
marking
CE<br />CCC<br />UKCA<br />EAC<br />RCM<br />CULus
[Uc] control circuit voltage
24 V DC
Discrete input number
4
Discrete input type
STOP) logic inputs, 3500 Ohm<br />RUN) logic inputs, 3500 Ohm<br />DI3) programmable as logic input, 3500 Ohm<br />DI4) programmable as logic input, 3500 Ohm
Input compatibility
STOP discrete input level 1 PLC IEC 61131-2<br />RUN discrete input level 1 PLC IEC 61131-2<br />DI3 discrete input level 1 PLC IEC 61131-2<br />DI4 discrete input level 1 PLC IEC 61131-2
Discrete input logic
Programmable digital input < 5 V
Relay output number
3
Relay output type
Relay outputs R1A 1 NO<br />Relay outputs R1B 1 NO<br />Relay outputs RIC NO/NC programmable
Minimum switching current
100 mA 12 V DC relay outputs
Maximum switching current
Relay outputs 2 A 250 V AC<br />Relay outputs 2 A 30 V DC<br />Relay outputs
Discrete output number
2
Discrete output type
DQ1) programmable digital output <= 30 V<br />DQ2) programmable digital output <= 30 V
Output compatibility
Open collector level 1 PLC IEC 65A-68
Analogue input number
1
Analogue input type
AI1/PTC PTC/Pt 100 temperature probe<br />PTC2 PTC/Pt 100 temperature probe<br />PTC3 PTC/Pt 100 temperature probe
Analogue output number
1
Analogue output type
Current output AQ1 0...20 mA or 0...10 V 500 Ohm
communication port protocol
Modbus serial
Connector Type
1 RJ45
Communication data link
Serial
Physical interface
2-wire RS 485
Transmission Rate
1200...256000 bit/s
Transmission frame
RTU
Data format
8 bits, configurable odd, even or no parity
Type of polarization
No impedance Modbus serial
Number of addresses
0…227 Modbus serial
Method of access
Slave Modbus serial
Function Available
External bypass control<br />Pre-heating<br />Smoke extraction<br />Multi-motor cascade<br />Second motor set<br />User management<br />Ports and services hardening<br />Security event logging<br />Cybersecure firmware update<br />Single direction
Display screen available
True
Operating position
Vertical +/- 10 degree
Height
35.04 in (890.0 mm)
Width
30.3 in (770.0 mm)
Depth
13.0 in (329.0 mm)
Net Weight
253.5 lb(US) (115.0 kg)
Electromagnetic compatibility
Conducted and radiated emissions level A IEC 60947-4-2<br />Conducted and radiated emissions with bypass level B IEC 60947-4-2<br />Damped oscillating waves level 3 IEC 61000-4-12<br />Electrostatic discharge level 3 IEC 61000-4-11<br />Immunity to electrical transients level 4 IEC 61000-4-4<br />Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3<br />Voltage/current impulse level 3 IEC 61000-4-5
Pollution degree
Level 3
[Uimp] rated impulse withstand voltage
6 kV
[Ui] Rated Insulation Voltage
690 V
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3<br />Class 3S2 according to IEC 60721-3-3
Relative humidity
0…95 % without condensation or dripping water IEC 60068-2-3
Ambient air temperature for operation
104…140 °F (40…60 °C) with current derating of 2 % per °C)<br />5…104 °F (-15…40 °C) without derating)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Operating altitude
<= 3280.84 ft (1000 m) without derating<br />> 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
Maximum deflection under vibratory load (during operation)
1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during storage)
1.75 mm at 2...9 Hz
Maximum deflection under vibratory load (during transport)
1.75 mm at 2...9 Hz
Maximum acceleration under vibrational stress (during operation)
10 m/s² at 13...200 Hz
Maximum acceleration under vibratory load (during storage)
15 m/s² at 200...500 Hz<br />10 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during transport)
15 m/s² at 200...500 Hz<br />10 m/s² at 9...200 Hz
Maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
Maximum acceleration under shock load (during storage)
100 m/s² at 11 ms
Maximum acceleration under shock load (during transport)
100 m/s² at 11 ms

Specifications may be subject to change without notice