Product Model

ATSU01N206LT

In Stock
Last updated: 2025/4/27
schneider ATSU01N206LT

Selling Points

  • 1Soft start and stop functions to limit starting current and reduce wear on motors.
  • 2Suitable for conveyors, conveyor belts, pumps, fans, belt-driven machinery, compressors, and small cranes.
  • 3Internal bypass relay ensures smooth operation and reliability in various industrial settings.
  • 4Requires an external power supply for control, making it straightforward to integrate into existing systems.
  • 5IP20 enclosure rating ensures protection against dust and water, extending the lifespan of the soft starter.
Product Details
ATSU01N206LT
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altistart U01 and TeSys U
Product or Component Type
Soft starter
Product destination
Asynchronous motors
Product Specific Application
Simple machine
Device short name
ATSU01
Phase
3 phase
[Us] rated supply voltage
200...480 V - 10...10 %
Motor power kW
3 kW, 3 phase 400 V<br />0.75 kW, 3 phase 230 V<br />2.2 kW, 3 phase 400 V<br />1 kW, 3 phase 230 V<br />1.5 kW, 3 phase 400 V
Maximum Horse Power Rating
1 hp, 3 phase 230 V<br />2 hp, 3 phase 460 V<br />3 hp, 3 phase 460 V<br />1.5 hp, 3 phase 230 V
IcL starter rating
6 A
Utilisation category
AC-53B EN/IEC 60947-4-2
Current consumption
65 mA
Type of start
Start with voltage ramp
Power dissipation in W
1.5 W at full load and at end of starting<br />61.5 W in transient state
Assembly style
With heat sink
Function Available
Integrated bypass
Supply voltage limits
180…528 V
Supply frequency
50...60 Hz - 5...5 %
Network Frequency
47.5...63 Hz
Output voltage
<= power supply voltage
[Uc] control circuit voltage
24 V DC +/- 10 %
Starting time
1 s / 100<br />5 s / 20<br />10 s / 10<br />Adjustable from 1 to 10 s
Deceleration time symb
Adjustable from 1 to 10 s
Starting torque
30...80 % of starting torque of motor connected directly on the line supply
Discrete input type
Logic LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
Discrete input voltage
24...40 V
Input output isolation
Galvanic between power and control
Discrete input logic
Positive LI1, LI2, BOOST < 5 V <= 0.2 mA > 13 V, >= 0.5 mA
Discrete output current
2 A DC-13<br />3 A AC-15
Discrete output type
Open collector logic LO1 end of starting signal<br />Relay outputs R1A, R1C NO
Discrete output voltage
24 V 6...30 V) open collector logic
Minimum switching current
10 mA 6 V DC relay outputs
Maximum switching current
Relay outputs 2 A 30 V DC cos phi = 0.5 20 ms inductive<br />Relay outputs 2 A 250 V AC AC-15 cos phi = 0.5 20 ms inductive
Maximum switching voltage
440 V relay outputs
Display type
1 LED Green)starter powered up<br />1 LED Yellow)nominal voltage reached
Tightening torque
16.8…22.1 lbf.in (1.9…2.5 N.m)<br />4.4 lbf.in (0.5 N.m)
Electrical connection
4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit<br />Screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit<br />4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit<br />Screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit<br />Screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit<br />4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit<br />Screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit<br />4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit<br />4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit<br />Screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
marking
CE
Operating position
Vertical +/- 10 degree
Height
9.2 in (234 mm)
Width
1.8 in (45 mm)
Depth
5.9 in (150 mm)
Net Weight
0.75 lb(US) (0.34 kg)
Motor power range AC-3
0.55…1 kW 200…240 V 3 phase<br />1.1…2 kW 380…440 V 3 phase<br />2.2…3 kW
Motor starter type
Soft starter
Electromagnetic compatibility
Conducted and radiated emissions level B CISPR 11<br />Conducted and radiated emissions level B IEC 60947-4-2<br />Damped oscillating waves level 3 IEC 61000-4-12<br />Electrostatic discharge level 3 IEC 61000-4-2<br />EMC immunity EN 50082-1<br />EMC immunity level B EN 50082-2<br />Harmonics level 3 IEC 1000-3-2<br />Harmonics level 3 IEC 1000-3-4<br />Immunity to electrical transients level 4 IEC 61000-4-4<br />Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3<br />Voltage/current impulse level 3 IEC 61000-4-5<br />Conducted and radiated emissions level 3 IEC 61000-4-6<br />Immunity to conducted interference caused by radio-electrical fields level 4 IEC 61000-4-11
Standards
EN/IEC 60947-4-2
Product Certifications
CCC<br />UL<br />C-tick<br />CSA
IP Degree of Protection
IP20
Pollution degree
2 EN/IEC 60947-4-2
Vibration resistance
1 gn 13…150 Hz)EN/IEC 60068-2-6<br />1.5 mm peak to peak 3…13 Hz)EN/IEC 60068-2-6
Shock resistance
15 gn 11 ms EN/IEC 60068-2-27
Relative humidity
5…95 % without condensation or dripping water EN/IEC 60068-2-3
Ambient air temperature for operation
14…104 °F (-10…40 °C) without derating)<br />104…122 °F (40…50 °C) with current derating of 2 % per °C)
Ambient air temperature for storage
-13…158 °F (-25…70 °C) EN/IEC 60947-4-2
Operating altitude
<= 3280.84 ft (1000 m) without derating<br />> 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m

Specifications may be subject to change without notice