Product Model
ATV11HU41M2E

Selling Points
- 1High Power Conversion: Converts 1-phase to 3-phase power with 2.2kW main power.
- 2Advanced Control Modes: Features built-in PID regulator and vector control mode without encoder.
- 3Efficient Operation: Operates at 150% maximum number for 1 minute, ensuring reliable performance.
- 4Compact Design: Measures 117 x 142 x 156 mm, with a weight of 1.8 kg.
- 5Comprehensive Warranty: Covered by a 24-month warranty with the possibility of extension.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altivar 11 | Product or Component Type | Variable speed drive |
Product Specific Application | Simple machine | Component name | ATV11 |
Application market | European | Assembly style | With heat sink |
EMC filter | Integrated | Built-in fan | With |
Phase | 1 phase | [Us] rated supply voltage | 200...240 V - 15...10 % |
Supply frequency | 50...60 Hz - 5...5 % | Motor power kW | 2.2 kW |
Line current | 20.8 A 230 V, Isc = 1 kA | Nominal output current | 9.6 A 230 V motor 4 kHz |
Maximum transient current | 14.4 A 60 s | Power dissipation in W | 96 W at nominal load |
Switching frequency | 2...16 kHz adjustable<br />4...16 kHz with derating factor | Braking torque | 150 % of nominal motor torque with braking resistor at high inertia<br />20 % of nominal motor torque without braking resistor at no load<br />80 % of nominal motor torque with braking resistor at no load |
Asynchronous motor control profile | Sensorless flux vector control with PWM type motor control signal | Electrical connection | Terminal 1.5 mm², AWG 14 AI1, RA-RC, LI1...LI4, DO)<br />Terminal 1.5 mm², AWG 14 L1, L2, L3, U, V, W, PA, PC) |
Supply | Internal supply for logic inputs 15 V +/- 15 %) 100 A overload and short-circuit protection<br />Internal supply for reference potentiometer (2.2 to 10 kOhm) 5...5.25 VDC 10 A overload and short-circuit protection | Analogue input type | Configurable current AI1 4...20 mA 250 Ohm without adding resistor<br />Configurable voltage AI1 0...5 V 40000 Ohm only with internal supply<br />Configurable current AI1 0...20 mA 250 Ohm<br />Configurable voltage AI1 0...10 V 40000 Ohm |
Sampling duration | AI1 20 ms analog<br />LI1...LI4 20 ms discrete | Response time | 20 ms DO |
Linearity error | DO +/- 1 % output<br />AI +/- 5 % input | Discrete input type | Assignable Ll1 forward 5000 Ohm 15 V 24 V<br />Assignable Ll2 reverse 5000 Ohm 15 V 24 V<br />Assignable Ll3/Ll4 4 preset speeds 5000 Ohm 15 V 24 V |
Discrete input logic | Positive logic (source) LI1...LI4), < 5 V, > 11 V | Discrete output type | Assignable as external voltage DO 30 V max, 30 mA<br />Assignable as open collector logic output DO 100 Ohm, 50 mA max<br />Factory set as PWM open collector output DO at 2 kHz 10 mA max<br />Protected relay logic RA-RC 1 NO<br />Assignable as internal voltage DO |
Minimum switching current | RA-RC 10 mA 24 V DC | Maximum switching current | 2 A 250 V AC inductive cos phi = 0.4 7 ms RA-RC<br />2 A 30 V DC inductive cos phi = 0.4 7 ms RA-RC<br />5 A 250 V AC resistive cos phi = 1 0 ms RA-RC<br />5 A 30 V DC resistive cos phi = 1 0 ms RA-RC |
Protection type | Line supply overvoltage drive<br />Line supply undervoltage drive<br />Overheating protection drive<br />Short-circuit between motor phases drive<br />Thermal protection motor<br />Overcurrent between output phases and earth drive | Frequency resolution | Display unit 0.1 Hz<br />Analog input converter A/D, 10 bits |
Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 EN/IEC 61000-4-5<br />Electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4<br />Electrostatic discharge immunity test level 3 EN/IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 | Maximum motor cable length | 32.8 ft (10 m) without additional EMC filter from 2 to 16 kHz EN 55011 class A group 1<br />32.8 ft (10 m) without additional EMC filter from 2 to 16 kHz EN 55022 class A group 1<br />65.6 ft (20 m) with additional EMC filter from 2 to 16 kHz EN 55011 class B<br />16.4 ft (5 m) without additional EMC filter from 2 to 12 kHz EN 55011 class B<br />16.4 ft (5 m) without additional EMC filter from 2 to 12 kHz EN 55022 class B<br />164.04 ft (50 m) with additional EMC filter from 2 to 16 kHz EN 55011 class A group 1 |
Vibration resistance | 1 gn 13…200 Hz)EN/IEC 60068-2-6<br />1.5 mm peak to peak 3…13 Hz)EN/IEC 60068-2-6 | Shock resistance | 15 gn 11 ms EN/IEC 60068-2-27 |
Relative humidity | 5…93 % without condensation IEC 60068-2-3<br />5…93 % without dripping water IEC 60068-2-3 | Ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating<br />104…122 °F (40…50 °C) by removing the protective cover from the top of the drive<br />122…140 °F (50…60 °C) by removing the protective cover from the top of the drive with current derating of 2.2 % per °C |
Operating altitude | <= 3280.84 ft (1000 m) without derating<br />> 3280.84 ft (1000 m) with current derating 1 % per 100 m | Product destination | Asynchronous motors |
Supply voltage limits | 170…264 V | Network frequency limits | 47.5…63 Hz |
Speed drive output frequency | 0…200 Hz | Nominal switching frequency | 4 kHz |
Speed range | 1…20 | Transient overtorque | 150...170 % of nominal motor torque |
Regulation loop | Factory-set with the speed loop stability and gain<br />Adjustable frequency<br />Possible correction for machines with high resistive torque/inertia/fast cycles | Motor slip compensation | Preset in factory<br />Adjustable |
Prospective line Isc | 1 kA | Output voltage | <= power supply voltage |
Insulation | Electrical between power and control | Analogue input number | 1 |
Discrete input number | 4 | Discrete output number | 2 |
Acceleration and deceleration ramps | Linear from 0 to 99.9 s | Braking to standstill | By DC injection |
Insulation resistance | > 500 MOhm | marking | CE |
Operating position | Vertical +/- 10 degree | CAD overall width | 4.6 in (117 mm) |
CAD overall height | 5.6 in (142 mm) | CAD overall depth | 6.1 in (156 mm) |
Outer dimension | 142 x 117 x 156 mm | Net Weight | 4.0 lb(US) (1.8 kg) |
Standards | EN 50178 | Product Certifications | CSA<br />C-tick<br />UL<br />N998 |
IP Degree of Protection | IP20 | Ambient Air Temperature for Storage | -13…149 °F (-25…65 °C) |
Variable speed drive application selection | Packaging conveyor | Motor power range AC-3 | 2.2…3 kW 200…240 V 1 phase |
Motor starter type | Variable speed drive |
Specifications may be subject to change without notice