Product Model
ATV312HU30M3412

Selling Points
- 13kW motor power with 6.6kVA rating.
- 2Operates at 200-240V with ±5% tolerance.
- 3Environmentally friendly and mercury-free.
- 4Suitable for pumping stations and photovoltaic arrays.
- 5Features 3 analogue inputs and 2 analogue outputs for precise control.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altivar 312 Solar | Product or Component Type | Variable speed drive |
Product destination | Asynchronous motors | Product Specific Application | Pumping station with photovoltaic arrays |
Assembly style | With heat sink | Device short name | ATV312 |
Motor power kW | 3 kW | [Us] rated supply voltage | 200...240 V - 5...5 % |
Supply voltage limits | 170…264 V | Supply frequency | 50...60 Hz - 5...5 % |
Network Frequency | 47.5...63 Hz | Phase | 3 phase |
Line current | 16.6 A 240 V<br />19.1 A 200 V, Isc = 1 kA | EMC filter | Without EMC filter |
Apparent power | 6.6 kVA | Prospective line Isc | 1 kA |
Continuous output current | 13.7 A 4 kHz | Maximum transient current | 20.6 A 60 s |
Power dissipation in W | 146 W at nominal load | Speed drive output frequency | 0.5…500 Hz |
Nominal switching frequency | 4 kHz | Switching frequency | 2...16 kHz adjustable |
Speed range | 1…50 | Transient overtorque | 150…170 % of nominal motor torque |
Braking torque | <= 150 % 60 s with braking resistor<br />100 % with braking resistor continuously<br />150 % without braking resistor | Asynchronous motor control profile | Factory set: energy saving mode |
Regulation loop | Frequency PI regulator | Motor slip compensation | Suppressable<br />Automatic whatever the load<br />Adjustable |
Output voltage | <= power supply voltage | Electrical connection | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 0.004 in² (2.5 mm²) AWG 14<br />L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 0.004 in² (2.5 mm²) AWG 14 |
Tightening torque | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 5.3 lbf.in (0.6 N.m)<br />L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 7.08 lbf.in (0.8 N.m) | Insulation | Electrical between power and control |
Supply | Internal supply for logic inputs 19...30 V, <100 A overload and short-circuit protection<br />Internal supply for reference potentiometer (2.2 to 10 kOhm) 10...10.8 V, <10 A overload and short-circuit protection | Analogue input number | 3 |
Analogue input type | AI1 configurable voltage 0...10 V 30 V max 30000 Ohm<br />AI2 configurable voltage +/- 10 V 30 V max 30000 Ohm<br />AI3 configurable current 0...20 mA 250 Ohm | Sampling duration | AI1, AI2, AI3 8 ms analog<br />LI1...LI6 4 ms discrete |
Response time | AOV, AOC 8 ms analog<br />R1A, R1B, R1C, R2A, R2B 8 ms discrete | Linearity error | +/- 0.2 % output |
Analogue output number | 2 | Analogue output type | AOC configurable current 0...20 mA 800 Ohm 8 bits<br />AOV configurable voltage 0...10 V 470 Ohm 8 bits |
Discrete input logic | Logic input not wired LI1...LI4), < 13 V<br />Negative logic (source) LI1...LI6), > 19 V<br />Positive logic (source) LI1...LI6), < 5 V, > 11 V | Discrete output number | 2 |
Discrete output type | Configurable relay logic R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles<br />Configurable relay logic R2A, R2B) NC - 100000 cycles | Minimum switching current | R1-R2 10 mA 5 V DC |
Maximum switching current | 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms R1-R2)<br />2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms R1-R2)<br />5 A 250 V AC resistive cos phi = 1 L/R = 0 ms R1-R2)<br />5 A 30 V DC resistive cos phi = 1 L/R = 0 ms R1-R2) | Discrete input number | 6 |
Discrete input type | LI1...LI6) programmable 24 V, 0…100 mA PLC 3500 Ohm | Acceleration and deceleration ramps | Linear adjustable separately from 0.1 to 999.9 s<br />S, U or customized |
Braking to standstill | By DC injection | Protection type | Input phase breaks drive<br />Line supply overvoltage and undervoltage safety circuits drive<br />Line supply phase loss safety function, for three phases supply drive<br />Motor phase breaks drive<br />Overcurrent between output phases and earth (on power up only) drive<br />Overheating protection drive<br />Short-circuit between motor phases drive<br />Thermal protection motor |
Dielectric strength | 2040 V DC between earth and power terminals<br />2880 V AC between control and power terminals | Insulation resistance | >= 500 mOhm 500 V DC for 1 minute |
Local signalling | for drive voltage 1 LED (red)<br /> for CANopen bus status four 7-segment display units | Time constant | 5 ms for reference change |
Frequency resolution | Analog input 0.1...100 Hz<br />Display unit 0.1 Hz | communication port protocol | CANopen<br />Modbus |
Connector type | 1 RJ45 Modbus/CANopen | Physical interface | RS485 multidrop serial link |
Transmission frame | RTU | Transmission Rate | 10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen<br />4800, 9600 or 19200 bps Modbus |
Number of addresses | 1…127 CANopen<br />1…247 Modbus | Number of drive | 127 CANopen<br />31 Modbus |
Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 | Standards | IEC 61800-3<br />IEC 61800-5-1 |
marking | CE | Height | 7.2 in (184 mm) |
Width | 5.6 in (142 mm) | Depth | 6.0 in (152 mm) |
Net Weight | 6.4 lb(US) (2.9 kg) | Option card | Communication card CANopen daisy chain<br />Communication card DeviceNet<br />Communication card Fipio<br />Communication card Modbus TCP<br />Communication card Profibus DP |
IP degree of protection | IP20 without cover plate | Pollution degree | 2 |
Protective treatment | TC | Vibration resistance | 1 gn 13…150 Hz)EN/IEC 60068-2-6<br />1.5 mm 3…13 Hz)EN/IEC 60068-2-6 |
Shock resistance | 15 gn 11 ms EN/IEC 60068-2-27 | Relative humidity | 5…95 % without condensation IEC 60068-2-3<br />5…95 % without dripping water IEC 60068-2-3 |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) | Ambient air temperature for operation | 14…122 °F (-10…50 °C) without derating with protective cover on top of the drive)<br />14…140 °F (-10…60 °C) with derating factor without protective cover on top of the drive) |
Operating altitude | <= 3280.84 ft (1000 m) without derating<br />>= 3280.84 ft (1000 m) with current derating 1 % per 100 m | Operating position | Vertical +/- 10 degree |
Specifications may be subject to change without notice