Product Model
ATV312HU55N4412

Selling Points
- 1High Efficiency: Optimized for 5.5kW applications with 15kVA power.
- 2Wide Voltage Range: Compatible with 380-500V three-phase supply.
- 3Robust Design: IP20 protection for reliable operation in various environments.
- 4Integrated EMC Filter: Ensures smooth operation with minimal electromagnetic interference.
- 5Advanced Features: Includes solar power regulation, tank control, and all-day run-stop-restart mode management.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altivar 312 Solar | Product or Component Type | Variable speed drive |
Product destination | Asynchronous motors | Product Specific Application | Pumping station with photovoltaic arrays |
Assembly style | With heat sink | Device short name | ATV312 |
Motor power kW | 5.5 kW | Maximum Horse Power Rating | 7.5 hp |
[Us] rated supply voltage | 380...500 V - 5...5 % | Supply voltage limits | 323…550 V |
Supply frequency | 50...60 Hz - 5...5 % | Network Frequency | 47.5...63 Hz |
Phase | 3 phase | Line current | 16.5 A 500 V<br />21.9 A 380 V, Isc = 1 kA |
EMC filter | Integrated | Apparent power | 15 kVA |
Prospective line Isc | 1 kA | Continuous output current | 14.3 A 4 kHz |
Maximum transient current | 21.5 A 60 s | Power dissipation in W | 232 W at nominal load |
Speed drive output frequency | 0.5…500 Hz | Nominal switching frequency | 4 kHz |
Switching frequency | 2...16 kHz adjustable | Speed range | 1…50 |
Transient overtorque | 150…170 % of nominal motor torque | Braking torque | <= 150 % 60 s with braking resistor<br />100 % with braking resistor continuously<br />150 % without braking resistor |
Asynchronous motor control profile | Factory set: energy saving mode | Regulation loop | Frequency PI regulator |
Motor slip compensation | Suppressable<br />Automatic whatever the load<br />Adjustable | Output voltage | <= power supply voltage |
Electrical connection | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 0.004 in² (2.5 mm²) AWG 14<br />L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 0.004 in² (2.5 mm²) AWG 14 | Tightening torque | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 5.3 lbf.in (0.6 N.m)<br />L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 7.08 lbf.in (0.8 N.m) |
Insulation | Electrical between power and control | Supply | Internal supply for logic inputs 19...30 V, <100 A overload and short-circuit protection<br />Internal supply for reference potentiometer (2.2 to 10 kOhm) 10...10.8 V, <10 A overload and short-circuit protection |
Analogue input number | 3 | Analogue input type | AI1 configurable voltage 0...10 V 30 V max 30000 Ohm<br />AI2 configurable voltage +/- 10 V 30 V max 30000 Ohm<br />AI3 configurable current 0...20 mA 250 Ohm |
Sampling duration | AI1, AI2, AI3 8 ms analog<br />LI1...LI6 4 ms discrete | Response time | AOV, AOC 8 ms analog<br />R1A, R1B, R1C, R2A, R2B 8 ms discrete |
Linearity error | +/- 0.2 % output | Analogue output number | 2 |
Analogue output type | AOC configurable current 0...20 mA 800 Ohm 8 bits<br />AOV configurable voltage 0...10 V 470 Ohm 8 bits | Discrete input logic | Logic input not wired LI1...LI4), < 13 V<br />Negative logic (source) LI1...LI6), > 19 V<br />Positive logic (source) LI1...LI6), < 5 V, > 11 V |
Discrete output number | 2 | Discrete output type | Configurable relay logic R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles<br />Configurable relay logic R2A, R2B) NC - 100000 cycles |
Minimum switching current | R1-R2 10 mA 5 V DC | Maximum switching current | 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms R1-R2)<br />2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms R1-R2)<br />5 A 250 V AC resistive cos phi = 1 L/R = 0 ms R1-R2)<br />5 A 30 V DC resistive cos phi = 1 L/R = 0 ms R1-R2) |
Discrete input number | 6 | Discrete input type | LI1...LI6) programmable 24 V, 0…100 mA PLC 3500 Ohm |
Acceleration and deceleration ramps | Linear adjustable separately from 0.1 to 999.9 s<br />S, U or customized | Braking to standstill | By DC injection |
Protection type | Input phase breaks drive<br />Line supply overvoltage and undervoltage safety circuits drive<br />Line supply phase loss safety function, for three phases supply drive<br />Motor phase breaks drive<br />Overcurrent between output phases and earth (on power up only) drive<br />Overheating protection drive<br />Short-circuit between motor phases drive<br />Thermal protection motor | Dielectric strength | 2410 V DC between earth and power terminals<br />3400 V AC between control and power terminals |
Insulation resistance | >= 500 mOhm 500 V DC for 1 minute | Local signalling | for drive voltage 1 LED (red)<br /> for CANopen bus status four 7-segment display units |
Time constant | 5 ms for reference change | Frequency resolution | Analog input 0.1...100 Hz<br />Display unit 0.1 Hz |
communication port protocol | CANopen<br />Modbus | Connector type | 1 RJ45 Modbus/CANopen |
Physical interface | RS485 multidrop serial link | Transmission frame | RTU |
Transmission Rate | 10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen<br />4800, 9600 or 19200 bps Modbus | Number of addresses | 1…127 CANopen<br />1…247 Modbus |
Number of drive | 127 CANopen<br />31 Modbus | Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 |
Standards | IEC 61800-3<br />IEC 61800-5-1 | marking | CE |
Height | 9.1 in (232 mm) | Width | 7.09 in (180 mm) |
Depth | 6.8 in (172 mm) | Net Weight | 14.3 lb(US) (6.5 kg) |
Option card | Communication card CANopen daisy chain<br />Communication card DeviceNet<br />Communication card Fipio<br />Communication card Modbus TCP<br />Communication card Profibus DP | IP degree of protection | IP20 without cover plate |
Pollution degree | 2 | Protective treatment | TC |
Vibration resistance | 1 gn 13…150 Hz)EN/IEC 60068-2-6<br />1.5 mm 3…13 Hz)EN/IEC 60068-2-6 | Shock resistance | 15 gn 11 ms EN/IEC 60068-2-27 |
Relative humidity | 5…95 % without condensation IEC 60068-2-3<br />5…95 % without dripping water IEC 60068-2-3 | Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Ambient air temperature for operation | 14…122 °F (-10…50 °C) without derating with protective cover on top of the drive)<br />14…140 °F (-10…60 °C) with derating factor without protective cover on top of the drive) | Operating altitude | <= 3280.84 ft (1000 m) without derating<br />>= 3280.84 ft (1000 m) with current derating 1 % per 100 m |
Operating position | Vertical +/- 10 degree |
Specifications may be subject to change without notice