Product Model

ATV312HU75N4B

In Stock
Last updated: 2025/4/22
schneider ATV312HU75N4B

Selling Points

  • 1High Efficiency: Achieve 98% full-load efficiency, minimizing energy loss and maximizing operational power.
  • 2Precise Control: Utilize flux vector control and voltage/frequency ratio control for precise and responsive motor control.
  • 3Robust Protection: Enjoy robust protection against dust, moisture, and other environmental factors with IP20 to IP41 protection levels.
  • 4Wide Speed Range: Operate within a wide speed range of 1 to 50, ensuring flexibility in industrial applications.
  • 5Seamless Integration: Facilitate seamless integration into automation networks with CANopen and Modbus communication protocols.
Product Details
ATV312HU75N4B
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altivar 312
Product or Component Type
Variable speed drive
Product destination
Asynchronous motors
Product Specific Application
Simple machine
Assembly style
With heat sink
Component name
ATV312
Motor power kW
7.5 kW
Maximum Horse Power Rating
10 hp
[Us] rated supply voltage
380...500 V - 15...10 %
Supply frequency
50...60 Hz - 5...5 %
Phase
3 phase
Line current
27.7 A 380 V, Isc = 22 kA<br />21 A 500 V
EMC filter
Integrated
Apparent power
18 kVA
Maximum transient current
25.5 A 60 s
Power dissipation in W
269 W at nominal load
Speed range
1…50
Asynchronous motor control profile
Sensorless flux vector control with PWM type motor control signal<br />Factory set : constant torque
Electrical connection
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 0.02 in² (16 mm²) AWG 6
Supply
Internal supply for logic inputs 19...30 V 100 mA overload and short-circuit protection<br />Internal supply for reference potentiometer (2.2 to 10 kOhm) 10...10.8 V 10 mA overload and short-circuit protection
communication port protocol
CANopen<br />Modbus
IP degree of protection
IP20 on upper part without cover plate<br />IP21 on connection terminals<br />IP31 on upper part<br />IP41 on upper part
Option card
Communication card CANopen daisy chain<br />Communication card DeviceNet<br />Communication card Fipio<br />Communication card Modbus TCP<br />Communication card Profibus DP
Supply voltage limits
323…550 V
Prospective line Isc
22 kA
Continuous output current
17 A 4 kHz
Output frequency
0…500 Hz
Nominal switching frequency
4 kHz
Switching frequency
2...16 kHz adjustable
Transient overtorque
170…200 % of nominal motor torque
Braking torque
150 % 60 s with braking resistor<br />100 % with braking resistor continuously<br />150 % without braking resistor
Regulation loop
Frequency PI regulator
Motor slip compensation
Suppressable<br />Automatic whatever the load<br />Adjustable
Output voltage
<= power supply voltage
Tightening torque
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 22.1 lbf.in (2.5 N.m)
Insulation
Electrical between power and control
Acceleration and deceleration ramps
S, U or customized<br />Linear adjustable separately from 0.1 to 999.9 s
Braking to standstill
By DC injection
Protection type
Input phase breaks drive<br />Line supply overvoltage and undervoltage safety circuits drive<br />Line supply phase loss safety function, for three phases supply drive<br />Motor phase breaks drive<br />Overcurrent between output phases and earth (on power up only) drive<br />Overheating protection drive<br />Short-circuit between motor phases drive<br />Thermal protection motor
Insulation resistance
>= 500 mOhm 500 V DC for 1 minute
Local signalling
for drive voltage 1 LED (red)<br /> for CANopen bus status four 7-segment display units
Time constant
5 ms for reference change
Frequency resolution
Analog input 0.1...100 Hz<br />Display unit 0.1 Hz
Connector type
1 RJ45 Modbus/CANopen
Physical interface
RS485 multidrop serial link
Transmission frame
RTU
Transmission Rate
10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen<br />4800, 9600 or 19200 bps Modbus
Number of addresses
1…127 CANopen<br />1…247 Modbus
Number of drive
127 CANopen<br />31 Modbus
marking
CE
Operating position
Vertical +/- 10 degree
Outer dimension
405 x 234 x 268 mm<br />300 x 210 x 170 mm<br />232 x 180 x 170 mm
Height
9.1 in (232 mm)
Width
7.09 in (180 mm)
Depth
6.8 in (172 mm)
Net Weight
14.3 lb(US) (6.5 kg)
Dielectric strength
2410 V DC between earth and power terminals<br />3400 V AC between control and power terminals
Electromagnetic compatibility
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Standards
IEC 61800-5-1<br />IEC 61800-3
Product Certifications
UL<br />NOM<br />C-tick<br />CSA<br />DNV<br />GOST
Pollution degree
2
Protective treatment
TC
Vibration resistance
1 gn 13…150 Hz)EN/IEC 60068-2-6<br />1.5 mm 3…13 Hz)EN/IEC 60068-2-6
Shock resistance
15 gn 11 ms EN/IEC 60068-2-27
Relative humidity
5…95 % without condensation IEC 60068-2-3<br />5…95 % without dripping water IEC 60068-2-3
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Ambient air temperature for operation
14…122 °F (-10…50 °C) without derating with protective cover on top of the drive)<br />14…140 °F (-10…60 °C) with derating factor without protective cover on top of the drive)
Operating altitude
<= 3280.84 ft (1000 m) without derating<br />3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m

Specifications may be subject to change without notice