Product Model

ATV31HU11N4

In Stock
Last updated: 2025/4/20
schneider ATV31HU11N4

Selling Points

  • 1Accurately control motor speed and torque for various industrial applications.
  • 2Automatically adjust motor speed to minimize energy expenditure and improve efficiency.
  • 3Dynamic and regenerative braking ensure safe and efficient deceleration, reducing wear and tear on motors.
  • 4Compatible with input voltage 380-500 V AC and output voltage 0-500 V AC, suitable for diverse industrial settings.
  • 5Includes motor phase loss detection, short circuit protection, overvoltage/under-voltage protection, and motor stall prevention for safe operation.
Product Details
ATV31HU11N4
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altivar
Product or Component Type
Variable speed drive
Product Specific Application
Simple machine
Component name
ATV31
Assembly style
With heat sink
EMC filter
Integrated
[Us] rated supply voltage
380...500 V - 5...5 %
Supply frequency
50...60 Hz - 5...5 %
Phase
3 phase
Motor power kW
1.1 kW 4 kHz
Maximum Horse Power Rating
1.5 hp 4 kHz
Line current
3.7 A 500 V<br />4.9 A 380 V, Isc = 1 kA
Apparent power
3.2 kVA
Prospective line Isc
1 kA
Nominal output current
3 A 4 kHz
Maximum transient current
4.5 A 60 s
Power dissipation in W
48 W at nominal load
Asynchronous motor control profile
Factory set : constant torque<br />Sensorless flux vector control with PWM type motor control signal
Analogue input number
3
Product destination
Asynchronous motors
Supply voltage limits
323…550 V
Network Frequency
47.5...63 Hz
Output frequency
0.0005…0.5 kHz
Nominal switching frequency
4 kHz
Switching frequency
2...16 kHz adjustable
Speed range
1…50
Transient overtorque
150…170 % of nominal motor torque
Braking torque
<= 150 % 60 s with braking resistor<br />100 % with braking resistor continuously<br />150 % without braking resistor
Regulation loop
Frequency PI regulator
Motor slip compensation
Adjustable<br />Suppressable<br />Automatic whatever the load
Output voltage
<= power supply voltage
Electrical connection
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 0.004 in² (2.5 mm²) AWG 14<br />L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 0.004 in² (2.5 mm²) AWG 14
Tightening torque
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 5.3 lbf.in (0.6 N.m)<br />L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- 7.08 lbf.in (0.8 N.m)
Insulation
Electrical between power and control
Supply
Internal supply for logic inputs 19...30 V 100 mA overload and short-circuit protection<br />Internal supply for reference potentiometer (2.2 to 10 kOhm) 10...10.8 V 10 mA overload and short-circuit protection
Analogue input type
AI3 configurable current 0...20 mA 250 Ohm<br />AI1 configurable voltage 0...10 V 30 V max 30000 Ohm<br />AI2 configurable voltage +/- 10 V 30 V max 30000 Ohm
Sampling duration
LI1...LI6 4 ms discrete<br />AI1, AI2, AI3 8 ms analog
Response time
AOV, AOC 8 ms analog<br />R1A, R1B, R1C, R2A, R2B 8 ms discrete
Linearity error
+/- 0.2 % output
Analogue output number
2
Analogue output type
AOC configurable current 0...20 mA 800 Ohm 8 bits<br />AOV configurable voltage 0...10 V 470 Ohm 8 bits
Discrete input logic
Positive logic (source) LI1...LI6), < 5 V, > 11 V<br />Logic input not wired LI1...LI4), < 13 V<br />Negative logic (source) LI1...LI6), > 19 V
Discrete output number
2
Discrete output type
Configurable relay logic R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles<br />Configurable relay logic R2A, R2B) NC - 100000 cycles
Minimum switching current
R1-R2 10 mA 5 V DC
Maximum switching current
R1-R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms<br />R1-R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms<br />R1-R2 5 A 250 V AC resistive, cos phi = 1 0 ms<br />R1-R2 5 A 30 V DC resistive, cos phi = 1 0 ms
Discrete input number
6
Discrete input type
LI1...LI6) programmable 24 V, 0…100 mA PLC 3500 Ohm
Acceleration and deceleration ramps
S, U or customized<br />Linear adjustable separately from 0.1 to 999.9 s
Braking to standstill
By DC injection
Protection type
Input phase breaks drive<br />Line supply overvoltage and undervoltage safety circuits drive<br />Line supply phase loss safety function, for three phases supply drive<br />Motor phase breaks drive<br />Overcurrent between output phases and earth (on power up only) drive<br />Overheating protection drive<br />Short-circuit between motor phases drive<br />Thermal protection motor
Insulation resistance
>= 500 mOhm 500 V DC for 1 minute
Display type
1 LED Red)drive voltage<br />Four 7-segment display unitsCANopen bus status
Time constant
5 ms for reference change
Frequency resolution
Display unit 0.1 Hz<br />Analog input 0.1...100 Hz
Connector type
1 RJ45 CANopen via VW3 CANTAP2 adaptor<br />1 RJ45 Modbus
Physical interface
RS485 multidrop serial link CANopen via VW3 CANTAP2 adaptor<br />RS485 multidrop serial link Modbus
Transmission frame
RTU CANopen via VW3 CANTAP2 adaptor<br />RTU Modbus
Transmission Rate
10, 20, 50, 125, 250, 500 kbps or 1 Mbps CANopen via VW3 CANTAP2 adaptor<br />4800, 9600 or 19200 bps Modbus
Number of addresses
1…127 CANopen via VW3 CANTAP2 adaptor<br />1…247 Modbus
Number of drive
127 CANopen via VW3 CANTAP2 adaptor<br />31 Modbus
marking
CE
Operating position
Vertical +/- 10 degree
Net Weight
4.0 lb(US) (1.8 kg)
Dielectric strength
2410 V DC between earth and power terminals<br />3400 V AC between control and power terminals
Electromagnetic compatibility
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Standards
EN 50178
Product Certifications
UL<br />N998<br />CSA<br />C-tick
IP degree of protection
On upper part: IP20 (without cover plate)<br />On connection terminals: IP21<br />On upper part: IP31<br />On upper part: IP41
Pollution degree
2
Protective treatment
TC
Vibration resistance
1 gn 13…150 Hz)EN/IEC 60068-2-6<br />1.5 mm 3…13 Hz)EN/IEC 60068-2-6
Shock resistance
15 gn 11 ms EN/IEC 60068-2-27
Relative humidity
5…95 % without condensation IEC 60068-2-3<br />5…95 % without dripping water IEC 60068-2-3
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Ambient air temperature for operation
14…122 °F (-10…50 °C) without derating with protective cover on top of the drive)<br />14…140 °F (-10…60 °C) with derating factor without protective cover on top of the drive)
Operating altitude
<= 3280.84 ft (1000 m) without derating<br />>= 3280.84 ft (1000 m) with current derating 1 % per 100 m

Specifications may be subject to change without notice