Product Model

ATV320D15M3C412

In Stock
Last updated: 2025/4/18
schneider ATV320D15M3C412

Selling Points

  • 1High-performance AC drive with 15 kW power rating.
  • 2Advanced control capabilities for precise motor control.
  • 3Compact design for easy integration into various industrial setups.
  • 4Robust construction for long-lasting durability in harsh environments.
  • 5Compatible with a wide range of motor types for versatile use.
Product Details
ATV320D15M3C412
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altivar Solar
Product or Component Type
Variable speed drive
Product Specific Application
Pumping applications
Variant
Standard version
Format of the drive
Compact
Mounting Mode
Wall mount
communication port protocol
Modbus serial<br />CANopen
Option card
communication module, Ethernet IP/Modbus TCP
[Us] rated supply voltage
200...240 V - 15...10 %
Nominal output current
66.0 A
Motor power kW
15.0 kW heavy duty
EMC filter
Without EMC filter
IP degree of protection
IP20
Discrete input number
7
Discrete input type
STO safe torque off, 24 V DC1.5 kOhm<br />DI1...DI6 logic inputs, 24 V DC 30 V)<br />DI5 programmable as pulse input 0…30 kHz, 24 V DC 30 V)
Discrete input logic
Positive logic (source)<br />Negative logic (sink)
Discrete output number
3
Discrete output type
Open collector DQ+ 0…1 kHz 30 V DC 100 mA<br />Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number
3
Analogue input type
AI1 voltage 0...10 V DC 30 kOhm 10 bits<br />AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits<br />AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits
Analogue output number
1
Analogue output type
Software-configurable current AQ1 0...20 mA 800 Ohm 10 bits<br />Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
Relay output number
2
Relay output type
Configurable relay logic R1A 1 NO 100000 cycles<br />Configurable relay logic R1B 1 NC 100000 cycles<br />Configurable relay logic R1C<br />Configurable relay logic R2A 1 NO 100000 cycles<br />Configurable relay logic R2C
Maximum switching current
Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC<br />Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC<br />Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC<br />Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC<br />Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC
Minimum switching current
Relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC
Method of access
Slave CANopen
Number of addresses
1…247<br />1…127
Data format
8 bits, configurable odd, even or no parity
Type of polarization
No impedance
4 quadrant operation possible
True
Asynchronous motor control profile
Voltage/frequency ratio, 5 points<br />Flux vector control without sensor, standard<br />Voltage/frequency ratio - Energy Saving, quadratic U/f<br />Flux vector control without sensor - Energy Saving<br />Voltage/frequency ratio, 2 points
Synchronous motor control profile
Vector control without sensor
Transient overtorque
170…200 % of nominal motor torque
Maximum output frequency
0.599 kHz
Acceleration and deceleration ramps
Linear<br />U<br />S<br />CUS<br />Ramp switching<br />Acceleration/deceleration ramp adaptation<br />Acceleration/deceleration automatic stop with DC injection<br />Automatic adaptation of ramp if braking capacity exceeded, by using resistor<br />Linear adjustable separately from 0.01 to 6000 s
Motor slip compensation
Automatic whatever the load<br />Adjustable 0...300 %<br />Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency
2...16 kHz adjustable<br />4...16 kHz with derating factor
Nominal switching frequency
4 kHz
Braking to standstill
By DC injection
Brake chopper integrated
True
Line current
79.7 A 200 V heavy duty)<br />67.1 A 240 V heavy duty)
Maximum Input Current per Phase
79.7 A
Maximum output voltage
240 V
Apparent power
27.9 kVA 240 V heavy duty)
Maximum transient current
99.0 A 60 s
Short-circuit protection
thermal protection
Network Frequency
50-60 Hz
Relative symmetric network frequency tolerance
5 %
Prospective line Isc
22 kA
Base load current at high overload
8.0 A
Power dissipation in W
Fan 551 W 200 V 4 kHz
Electrical connection
Screw terminal 0.5...1.5 mm² analog input<br />Screw terminal analog output<br />Screw terminal
With safety function Safely Limited Speed (SLS)
True
With safety function Safe brake management (SBC/SBT)
False
With safety function Safe Operating Stop (SOS)
False
With safety function Safe Position (SP)
False
With safety function Safe programmable logic
False
With safety function Safe Speed Monitor (SSM)
False
With safety function Safe Stop 1 (SS1)
True
With sft fct Safe Stop 2 (SS2)
False
With safety function Safe torque off (STO)
True
With safety function Safely Limited Position (SLP)
False
With safety function Safe Direction (SDI)
False
Protection type
Input phase breaks drive<br />Overcurrent between output phases and earth drive<br />Overheating protection drive<br />Short-circuit between motor phases drive<br />Thermal protection drive
Width
7.09 in (180 mm)
Height
13.0 in (330 mm)
Depth
7.8 in (198.0 mm)
Net Weight
15.2 lb(US) (6.9 kg)
Power factor
0.618 at 230 V
Braking torque
170 % with braking resistor
Local signalling
for drive fault 1 LED (red)<br /> for CANopen error 1 LED (red)<br /> for CANopen run 1 LED (green)
Operating altitude
3280.84...6561.68 ft (1000...2000 m) with current derating 1 % per 100 m<br /><= 3280.84 ft (1000 m) without derating
Operating position
Vertical +/- 10 degree
Product Certifications
CE<br />UR<br />UKCA<br />RCM
Marking
CE<br />UR<br />UKCA<br />RCM
Standards
IEC 61800-5-1
Assembly style
With heat sink
Electromagnetic compatibility
Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test level 3 IEC 61000-4-6<br />Voltage dips and interruptions immunity test IEC 61000-4-11
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3<br />Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)
10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)
1.5 mm at 2...13 Hz
Permitted relative humidity (during operation)
Class 3K5 according to EN 60721-3
Volume of cooling air
41211.6 Gal/hr(US) (156.0 m3/h)
Overvoltage category
II
Regulation loop
Adjustable PID regulator
Speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
Noise level
58 dB
Pollution degree
2
Ambient air transport temperature
-13…158 °F (-25…70 °C)
Ambient air temperature for operation
14…122 °F (-10…50 °C) without derating<br />122…140 °F (50…60 °C) with derating factor
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)

Specifications may be subject to change without notice