Product Model
ATV340U55N4

Selling Points
- 15.5kW / 7.5hp for efficient motor control.
- 2Operates from 380V to 480V AC, suitable for various industrial settings.
- 3Reduces electromagnetic interference for a stable drive performance.
- 4Standard integration for seamless connectivity and control.
- 5Meets international standards for immunity and EMC emissions, ensuring reliability in harsh environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altivar Machine ATV340 | Product or Component Type | Variable speed drive |
Product Specific Application | Machine | Mounting Mode | Cabinet mount |
Variant | Standard version | communication port protocol | Modbus serial |
Option card | communication module, Profibus DP V1<br /> communication module, PROFINET<br /> communication module, DeviceNet<br /> communication module, CANopen<br /> communication module, EtherCAT | Phase | 3 phase |
Supply frequency | 50...60 Hz +/- 5 % | [Us] rated supply voltage | 380...480 V - 15...10 % |
Nominal output current | 12.7 A | Motor power kW | 7.5 kW normal duty<br />5.5 kW heavy duty |
Maximum Horse Power Rating | 10 hp normal duty<br />7 hp heavy duty | EMC filter | Class C3 EMC filter integrated |
IP degree of protection | IP20 | Discrete input number | 5 |
Discrete input type | PTI programmable as pulse input 0…30 kHz, 24 V DC 30 V)<br />DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm<br /> programmable | number of preset speeds | 16 preset speeds |
Discrete output number | 2.0 | Discrete output type | Programmable output DQ1, DQ2 30 V DC 100 mA |
Analogue input number | 2 | Analogue input type | AI1 software-configurable current 0...20 mA 250 Ohm 12 bits<br />AI1 software-configurable temperature probe or water level sensor<br />AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits<br />AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits |
Analogue output number | 1 | Analogue output type | Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits<br />Software-configurable current AQ1 0...20 mA 500 Ohm 10 bits |
Relay output number | 2 | Output voltage | <= power supply voltage |
Relay output type | Relay outputs R1A<br />Relay outputs R1C 100000 cycles<br />Relay outputs R2A<br />Relay outputs R2C 100000 cycles | Maximum switching current | Relay output R1C resistive, cos phi = 1 3 A 250 V AC<br />Relay output R1C resistive, cos phi = 1 3 A 30 V DC<br />Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC<br />Relay output R2C resistive, cos phi = 1 5 A 250 V AC<br />Relay output R2C resistive, cos phi = 1 5 A 30 V DC<br />Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
Minimum switching current | Relay output R1B 5 mA 24 V DC<br />Relay output R2C 5 mA 24 V DC | Physical interface | 2-wire RS 485 |
Connector Type | 1 RJ45 | Method of access | Slave Modbus RTU |
Transmission Rate | 4.8 kbit/s<br />9.6 kbit/s<br />19.2 kbit/s<br />38.4 kbit/s | Transmission frame | RTU |
Number of addresses | 1…247 | Data format | 8 bits, configurable odd, even or no parity |
Type of polarization | No impedance | 4 quadrant operation possible | True |
Asynchronous motor control profile | Variable torque standard<br />Optimized torque mode<br />Constant torque standard | Synchronous motor control profile | Permanent magnet motor<br />Reluctance motor |
Pollution degree | 2 | Maximum output frequency | 0.599 kHz |
Acceleration and deceleration ramps | Linear adjustable separately from 0.01...9999 s<br />S, U or customized | Motor slip compensation | Adjustable<br />Automatic whatever the load<br />Can be suppressed<br />Not available in permanent magnet motor law |
Switching frequency | 2...16 kHz adjustable<br />7...16 kHz with derating factor | Nominal switching frequency | 4 kHz |
Braking to standstill | By DC injection | Brake chopper integrated | True |
Line current | 20 A 380 V without line choke heavy duty)<br />16 A 480 V without line choke heavy duty)<br />15.3 A 380 V with external line choke normal duty)<br />12.2 A 480 V with external line choke normal duty)<br />11.6 A 380 V with external line choke heavy duty)<br />9.4 A 480 V with external line choke heavy duty) | Maximum Input Current per Phase | 20.0 A |
Maximum output voltage | 480 V | Apparent power | 12.1 kVA 480 V normal duty)<br />13.3 kVA 480 V heavy duty) |
Maximum transient current | 18.2 A 60 s normal duty)<br />19.1 A 60 s heavy duty)<br />22.3 A 2 s normal duty)<br />22.9 A 2 s heavy duty) | Electrical connection | DC bus screw terminal 4...6 mm² AWG 12...AWG 10<br />Control screw terminal 0.2...2.5 mm² AWG 24...AWG 12<br />Line side screw terminal 1.5...6 mm² AWG 14...AWG 10<br />Motor screw terminal 1.5...6 mm² AWG 14...AWG 10 |
Prospective line Isc | 22 kA | Base load current at high overload | 12.7 A |
Base load current at low overload | 16.5 A | Power dissipation in W | Natural convection 134 W 380 V 4 kHz heavy duty)<br />Forced convection 134 W 380 V 4 kHz heavy duty)<br />Natural convection 164 W 380 V 4 kHz normal duty)<br />Forced convection 164 W 380 V 4 kHz normal duty) |
With safety function Safely Limited Speed (SLS) | True | With safety function Safe brake management (SBC/SBT) | True |
With safety function Safe Operating Stop (SOS) | False | With safety function Safe Position (SP) | False |
With safety function Safe programmable logic | False | With safety function Safe Speed Monitor (SSM) | False |
With safety function Safe Stop 1 (SS1) | True | With sft fct Safe Stop 2 (SS2) | False |
With safety function Safe torque off (STO) | True | With safety function Safely Limited Position (SLP) | False |
With safety function Safe Direction (SDI) | False | Protection type | Thermal protection motor<br />Safe torque off motor<br />Motor phase loss motor<br />Thermal protection drive<br />Safe torque off drive<br />Overheating drive<br />Overcurrent drive<br />Output overcurrent between motor phase and earth drive<br />Output overcurrent between motor phases drive<br />Short-circuit between motor phase and earth drive<br />Short-circuit between motor phases drive<br />Motor phase loss drive<br />DC Bus overvoltage drive<br />Line supply overvoltage drive<br />Line supply undervoltage drive<br />Input supply loss drive<br />Exceeding limit speed drive<br />Break on the control circuit drive |
Width | 4.3 in (110.0 mm) | Height | 10.6 in (270.0 mm) |
Depth | 9.2 in (234.0 mm) | Net Weight | 6.4 lb(US) (2.9 kg) |
Continuous output current | 16.5 A 4 kHz normal duty<br />12.7 A 4 kHz heavy duty | Operating altitude | <= 9842.52 ft (3000 m) with current derating above 1000m |
Operating position | Vertical +/- 10 degree | Product Certifications | UL<br />CSA<br />TÜV<br />EAC<br />CTick |
marking | CE | Standards | IEC 61800-3<br />IEC 61800-5-1<br />IEC 60721-3<br />IEC 61508<br />IEC 13849-1<br />UL 618000-5-1<br />UL 508C |
Assembly style | With heat sink | Electromagnetic compatibility | Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test level 3 IEC 61000-4-6 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3<br />Class 3S3 according to IEC 60721-3-3 | Maximum acceleration under shock impact (during operation) | 70 m/s² at 22 ms |
Maximum acceleration under vibrational stress (during operation) | 5 m/s² at 9...200 Hz | Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...9 Hz |
Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 | Volume of cooling air | 20077.4 Gal/hr(US) (76.0 m3/h) |
Type of cooling | Forced convection | Overvoltage category | Class III |
Regulation loop | Adjustable PID regulator | Noise level | 46.6 dB |
Ambient air transport temperature | -40…158 °F (-40…70 °C) | Ambient air temperature for operation | 5…122 °F (-15…50 °C) without derating vertical position)<br />122…140 °F (50…60 °C) with derating factor vertical position) |
Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) | Isolation | Between power and control terminals |
Specifications may be subject to change without notice