Product Model
ATV340U75N4E

Selling Points
- 1High-Performance Drive: Designed for harsh environments with high temperature resistance up to 60 °C.
- 2Heavy-Duty Capability: Rated for 7.5 kW / 10 hp heavy-duty applications.
- 3Multi-Protocol Communication: Supports Ethernet IP and Modbus TCP for seamless integration.
- 4Comprehensive Certifications: CE, UL, CSA, and TÜV certified for reliability and safety.
- 5Versatile Applications: Suitable for packaging, material handling, and hoisting operations.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altivar Machine ATV340 | Product or Component Type | Variable speed drive |
Product Specific Application | Machine | Mounting Mode | Cabinet mount |
Variant | Standard version | communication port protocol | EtherNet/IP<br />Modbus serial<br />Modbus TCP |
Phase | 3 phase | Supply frequency | 50...60 Hz +/- 5 % |
[Us] rated supply voltage | 380...480 V - 15...10 % | Nominal output current | 16.5 A |
Motor power kW | 11 kW normal duty<br />7.5 kW heavy duty | Maximum Horse Power Rating | 15 hp normal duty<br />10 hp heavy duty |
EMC filter | Class C3 EMC filter integrated | IP degree of protection | IP20 |
Discrete input number | 5 | Discrete input type | PTI programmable as pulse input 0…30 kHz, 24 V DC 30 V)<br />DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm<br /> programmable |
number of preset speeds | 16 preset speeds | Discrete output number | 2.0 |
Discrete output type | Programmable output DQ1, DQ2 30 V DC 100 mA | Analogue input number | 2 |
Analogue input type | AI1 software-configurable current 0...20 mA 250 Ohm 12 bits<br />AI1 software-configurable temperature probe or water level sensor<br />AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits<br />AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits | Analogue output number | 1 |
Analogue output type | Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits<br />Software-configurable current AQ1 0...20 mA 500 Ohm 10 bits | Relay output number | 2 |
Output voltage | <= power supply voltage | Relay output type | Relay outputs R1A<br />Relay outputs R1C 100000 cycles<br />Relay outputs R2A<br />Relay outputs R2C 100000 cycles |
Maximum switching current | Relay output R1C resistive, cos phi = 1 3 A 250 V AC<br />Relay output R1C resistive, cos phi = 1 3 A 30 V DC<br />Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC<br />Relay output R2C resistive, cos phi = 1 5 A 250 V AC<br />Relay output R2C resistive, cos phi = 1 5 A 30 V DC<br />Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC | Minimum switching current | Relay output R1B 5 mA 24 V DC<br />Relay output R2C 5 mA 24 V DC |
Physical interface | 2-wire RS 485 | Connector Type | 3 RJ45 |
Method of access | Slave Modbus RTU<br />Slave Modbus TCP | Transmission Rate | 4.8 kbit/s<br />9.6 kbit/s<br />19.2 kbit/s<br />38.4 kbit/s |
Transmission frame | RTU | Number of addresses | 1…247 |
Data format | 8 bits, configurable odd, even or no parity | Type of polarization | No impedance |
4 quadrant operation possible | True | Asynchronous motor control profile | Variable torque standard<br />Constant torque standard<br />Optimized torque mode |
Synchronous motor control profile | Reluctance motor<br />Permanent magnet motor | Pollution degree | 2 |
Maximum output frequency | 0.599 kHz | Acceleration and deceleration ramps | S, U or customized<br />Linear adjustable separately from 0.01...9999 s |
Motor slip compensation | Automatic whatever the load<br />Not available in permanent magnet motor law<br />Can be suppressed<br />Adjustable | Switching frequency | 2...16 kHz adjustable<br />4...16 kHz with derating factor |
Nominal switching frequency | 4 kHz | Braking to standstill | By DC injection |
Brake chopper integrated | True | Line current | 25.6 A 380 V without line choke heavy duty)<br />20.4 A 480 V without line choke heavy duty)<br />22 A 380 V with external line choke normal duty)<br />17.7 A 480 V with external line choke normal duty)<br />14.6 A 380 V with external line choke heavy duty)<br />12.1 A 480 V with external line choke heavy duty) |
Maximum Input Current per Phase | 25.6 A | Maximum output voltage | 480 V |
Apparent power | 17 kVA 480 V normal duty)<br />17 kVA 480 V heavy duty) | Maximum transient current | 26.4 A 60 s normal duty)<br />24.8 A 60 s heavy duty)<br />32.4 A 2 s normal duty)<br />29.7 A 2 s heavy duty) |
Electrical connection | DC bus screw terminal 4...6 mm² AWG 12...AWG 10<br />Control screw terminal 0.2...2.5 mm² AWG 24...AWG 12<br />Motor screw terminal 1.5...6 mm² AWG 14...AWG 10<br />Line side screw terminal 2.5...6 mm² AWG 12...AWG 10 | Prospective line Isc | 22 kA |
Base load current at high overload | 16.5 A | Base load current at low overload | 24.0 A |
Power dissipation in W | Natural convection 180 W 380 V 4 kHz heavy duty)<br />Forced convection 180 W 380 V 4 kHz heavy duty)<br />Natural convection 249 W 380 V 4 kHz normal duty)<br />Forced convection 249 W 380 V 4 kHz normal duty) | With safety function Safely Limited Speed (SLS) | True |
With safety function Safe brake management (SBC/SBT) | True | With safety function Safe Operating Stop (SOS) | False |
With safety function Safe Position (SP) | False | With safety function Safe programmable logic | False |
With safety function Safe Speed Monitor (SSM) | False | With safety function Safe Stop 1 (SS1) | True |
With sft fct Safe Stop 2 (SS2) | False | With safety function Safe torque off (STO) | True |
With safety function Safely Limited Position (SLP) | False | With safety function Safe Direction (SDI) | False |
Protection type | Thermal protection motor<br />Safe torque off motor<br />Motor phase loss motor<br />Thermal protection drive<br />Safe torque off drive<br />Overheating drive<br />Overcurrent drive<br />Output overcurrent between motor phase and earth drive<br />Output overcurrent between motor phases drive<br />Short-circuit between motor phase and earth drive<br />Short-circuit between motor phases drive<br />Motor phase loss drive<br />DC Bus overvoltage drive<br />Line supply overvoltage drive<br />Line supply undervoltage drive<br />Input supply loss drive<br />Exceeding limit speed drive<br />Break on the control circuit drive | Width | 4.3 in (110.0 mm) |
Height | 10.6 in (270.0 mm) | Depth | 9.2 in (234.0 mm) |
Net Weight | 6.6 lb(US) (3.0 kg) | Continuous output current | 24 A 4 kHz normal duty<br />16.5 A 4 kHz heavy duty |
Operating altitude | <= 9842.52 ft (3000 m) with current derating above 1000m | Operating position | Vertical +/- 10 degree |
Product Certifications | UL<br />CSA<br />TÜV<br />EAC<br />CTick | marking | CE |
Standards | IEC 61800-3<br />IEC 61800-5-1<br />IEC 60721-3<br />IEC 61508<br />IEC 13849-1<br />UL 618000-5-1<br />UL 508C | Assembly style | With heat sink |
Electromagnetic compatibility | Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test level 3 IEC 61000-4-6 | Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3<br />Class 3S3 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 70 m/s² at 22 ms | Maximum acceleration under vibrational stress (during operation) | 5 m/s² at 9...200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...9 Hz | Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
Volume of cooling air | 20077.4 Gal/hr(US) (76.0 m3/h) | Type of cooling | Forced convection |
Overvoltage category | Class III | Regulation loop | Adjustable PID regulator |
Noise level | 46.5 dB | Ambient air transport temperature | -40…158 °F (-40…70 °C) |
Ambient air temperature for operation | 5…122 °F (-15…50 °C) without derating vertical position)<br />122…140 °F (50…60 °C) with derating factor vertical position) | Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
Isolation | Between power and control terminals |