Product Model

ATV61HU75S6X

In Stock
Last updated: 2025/4/19
schneider ATV61HU75S6X

Selling Points

  • No selling points available for this product.
Product Details
ATV61HU75S6X
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
Altivar 61
Product or Component Type
Variable speed drive
Product Specific Application
Pumping and ventilation machine
Component name
ATV61
Motor power kW
7.5 kW, 3 phase 500 V
Maximum Horse Power Rating
10 hp, 3 phase 575 V
power supply voltage
500...600 V - 15...10 %
supply number of phases
3 phase
Line current
21.4 A 500 V 3 phase 7.5 kW / 10 hp<br />18.4 A 600 V 3 phase 7.5 kW / 10 hp
EMC filter
Without EMC filter
Assembly style
With heat sink
maximum prospective line Isc
22 kA 3 phase
Maximum transient current
16.2 A 60 s, 3 phase
Nominal switching frequency
4 kHz
Switching frequency
2.5...6 kHz adjustable<br />4...6 kHz with derating factor
asynchronous motor control
Voltage/frequency ratio - Energy Saving, quadratic U/f<br />Flux vector control without sensor, standard<br />Voltage/frequency ratio, 5 points<br />Voltage/frequency ratio, 2 points
Synchronous motor control profile
Vector control without sensor, standard
communication port protocol
Modbus<br />CANopen
Type of polarization
No impedance Modbus
Option card
Communication card APOGEE FLN<br />Communication card BACnet<br />Communication card CC-Link<br />Controller inside programmable card<br />Communication card DeviceNet<br />Communication card EtherNet/IP<br />Communication card Fipio<br />I/O extension card<br />Communication card Interbus-S<br />Communication card LonWorks<br />Communication card METASYS N2<br />Communication card Modbus Plus<br />Communication card Modbus TCP<br />Communication card Modbus/Uni-Telway<br />Multi-pump card<br />Communication card Profibus DP<br />Communication card Profibus DP V1
Product destination
Asynchronous motors<br />Synchronous motors
power supply voltage limits
425…660 V
power supply frequency
50...60 Hz - 5...5 %
power supply frequency limits
47.5...63 Hz
Continuous output current
11 A 4 kHz, 575 V - 3 phase<br />13.5 A 4 kHz, 500 V - 3 phase
Output frequency
0.1…599 Hz
Speed range
1…100 in open-loop mode, without speed feedback
Speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
Torque accuracy
+/- 15 % in open-loop mode, without speed feedback
Transient overtorque
130 % of nominal motor torque +/- 10 % 60 s
Braking torque
<= 125 % with braking resistor<br />30 % without braking resistor
Regulation loop
Frequency PI regulator
Motor slip compensation
Adjustable<br />Not available in voltage/frequency ratio (2 or 5 points)<br />Automatic whatever the load<br />Can be suppressed
diagnostic
for drive voltage 1 LED (red)
Output voltage
<= power supply voltage
electrical isolation
Between power and control terminals
type of cable for mounting in an enclosure
With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC<br />With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC<br />Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC<br />Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical connection
Terminal 2.5 mm² / AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)<br />Terminal 16 mm² / AWG 4 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Tightening torque
5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)<br />26.6 lbf.in (3 N.m), 26.5 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC, +/- 5 %, <10 mA overload and short-circuit protection<br />Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection<br />External supply 24 V DC 19…30 V)
Analogue input number
2
Analogue input type
AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign<br />AI2 software-configurable current 0...20 mA 242 Ohm 11 bits<br />AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits
sampling time
2 ms +/- 0.5 ms AI1-/Al1+) - analog input<br />2 ms +/- 0.5 ms Al2) - analog input<br />2 ms +/- 0.5 ms AO1) - analog output<br />2 ms +/- 0.5 ms LI1...LI5) - discrete input<br />2 ms +/- 0.5 ms LI6)if configured as logic input - discrete input
absolute accuracy precision
+/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C<br />+/- 0.6 % AI2) for a temperature variation 60 °C<br />+/- 1 % AO1) for a temperature variation 60 °C
Linearity error
+/- 0.15 % of maximum value AI1-/Al1+)<br />+/- 0.15 % of maximum value AI2)<br />+/- 0.2 % AO1)
Analogue output number
1
Analogue output type
AO1 software-configurable current 0...20 mA 500 Ohm 10 bits<br />AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits<br />AO1 software-configurable logic output 10 V, 20 mA
Discrete output number
2
Discrete output type
Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles<br />Configurable relay logic R2A, R2B) NO - 100000 cycles
maximum response time
<= 100 ms in STO (Safe Torque Off)<br />R1A, R1B, R1C <= 7 ms +/- 0.5 ms<br />R2A, R2B <= 7 ms +/- 0.5 ms
Minimum switching current
3 mA 24 V DC configurable relay logic
Maximum switching current
R1, R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms<br />R1, R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms<br />R1, R2 5 A 250 V AC resistive, cos phi = 1 0 ms<br />R1, R2 5 A 30 V DC resistive, cos phi = 1 0 ms
Discrete input number
7
Discrete input type
Programmable LI1...LI5) 24 V DC <= 30 V)level 1 PLC - 3500 Ohm<br />Switch-configurable LI6) 24 V DC <= 30 V)level 1 PLC - 3500 Ohm<br />Switch-configurable PTC probe LI6)0…6 - 1500 Ohm<br />Safety input PWR) 24 V DC <= 30 V) - 1500 Ohm
Discrete input logic
Negative logic (sink) LI1...LI5), > 16 V, < 10 V<br />Positive logic (source) LI1...LI5), < 5 V, > 11 V<br />Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V<br />Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V
Acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s<br />S, U or customized<br />Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Braking to standstill
By DC injection
Protection type
Against exceeding limit speed drive<br />Against input phase loss drive<br />Break on the control circuit drive<br />Input phase breaks drive<br />Line supply overvoltage drive<br />Line supply undervoltage drive<br />Overcurrent between output phases and earth drive<br />Overheating protection drive<br />Overvoltages on the DC bus drive<br />Power removal drive<br />Short-circuit between motor phases drive<br />Thermal protection drive<br />Motor phase break motor<br />Power removal motor<br />Thermal protection motor
Insulation resistance
> 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution
Analog input 0.024/50 Hz<br />Display unit 0.1 Hz
Connector type
1 RJ45 on front face)Modbus<br />1 RJ45 on terminal)Modbus<br />Male SUB-D 9 on RJ45CANopen
Physical interface
2-wire RS 485 Modbus
Transmission frame
RTU Modbus
Transmission rate
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal<br />9600 bps, 19200 bps Modbus on front face<br />20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
Data format
8 bits, 1 stop, even parity Modbus on front face<br />8 bits, odd even or no configurable parity Modbus on terminal
Number of addresses
1…127 CANopen<br />1…247 Modbus
Method of access
Slave CANopen
marking
CE
Operating position
Vertical +/- 10 degree
Net Weight
17.6 lb(US) (8 kg)
Width
8.3 in (210 mm)
Height
11.6 in (295 mm)
Depth
8.4 in (213 mm)
Noise level
60.2 dB 86/188/EEC
Dielectric strength
5092 V DC between control and power terminals<br />3800 V DC between earth and power terminals
Electromagnetic compatibility
Conducted radio-frequency immunity test level 3 IEC 61000-4-6<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Voltage dips and interruptions immunity test IEC 61000-4-11
Standards
IEC 60721-3-3 class 3C1<br />EN/IEC 61800-3<br />EN/IEC 61800-5-1<br />EN/IEC 61800-3 environment 1<br />EN 55011 group 1 class B<br />EN/IEC 61800-3 environment 2<br />IEC 60721-3-3 class 3S2<br />UL Type 1
Product Certifications
GOST<br />CSA<br />C-tick<br />NOM 117<br />UL
Pollution degree
3 EN/IEC 61800-5-1<br />3 UL 840
degree of proctection
IP20 on upper part without blanking plate on cover EN/IEC 60529<br />IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1<br />IP21 EN/IEC 60529<br />IP21 EN/IEC 61800-5-1<br />IP41 on upper part EN/IEC 60529<br />IP41 on upper part EN/IEC 61800-5-1<br />IP54 on lower part EN/IEC 60529<br />IP54 on lower part EN/IEC 61800-5-1
Vibration resistance
1 gn 13…200 Hz)EN/IEC 60068-2-6<br />1.5 mm peak to peak 3…13 Hz)EN/IEC 60068-2-6
Shock resistance
15 gn 11 ms EN/IEC 60068-2-27
Relative humidity
5…95 % without condensation IEC 60068-2-3<br />5…95 % without dripping water IEC 60068-2-3
Ambient air temperature for operation
14…122 °F (-10…50 °C) without derating)<br />122…140 °F (50…60 °C) with derating factor)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Operating altitude
<= 3280.84 ft (1000 m) without derating<br />3280.84...7414.7 ft (1000...2260 m) with current derating 1 % per 100 m

Specifications may be subject to change without notice