Product Model
ATV630C11N4

Selling Points
- 1Advanced Energy Monitoring: Accurate measurement for monitoring system energy consumption with deviation <5%.
- 2Predictive Maintenance: Embedded Ethernet for direct access to system configuration and monitoring, enabling predictive and preventive maintenance tracking.
- 3Robust IP Ratings: NEMA 1/IP00/IP20/IP21 enclosure for reliable operation in various environments.
- 4High Power Rating: 125 hp at normal duty, 150 hp at heavy duty, suitable for demanding industrial applications.
- 5Sustainable Design: Compliant with RoHS/REACH regulations, ensuring environmental sustainability and compliance with global eco-label standards.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altivar Process ATV600 | Product or Component Type | Variable speed drive |
Product Specific Application | Process and utilities | Device short name | ATV630 |
Variant | Standard version | Product destination | Asynchronous motors<br />Synchronous motors |
EMC filter | Integrated 492.1 ft (150 m) IEC 61800-3 category C3 | IP degree of protection | IP00IEC 61800-5-1<br />IP00IEC 60529<br />IP21 with kit VW3A9704)IEC 61800-5-1<br />IP21 with kit VW3A9704)IEC 60529 |
[Us] rated supply voltage | 380...480 V - 15...10 % | Type of cooling | Forced convection |
Supply frequency | 50...60 Hz - 5...5 % | Motor power kW | 110 kW normal duty)<br />90 kW heavy duty) |
Maximum Horse Power Rating | 150 hp normal duty<br />125 hp heavy duty | Line current | 201 A 380 V normal duty)<br />165 A 480 V normal duty)<br />170 A 380 V heavy duty)<br />143 A 480 V heavy duty) |
Prospective line Isc | 50 kA | Apparent power | 121.8 kVA 480 V normal duty)<br />102.6 kVA 480 V heavy duty) |
Continuous output current | 211 A 2.5 kHz normal duty<br />173 A 2.5 kHz heavy duty | Asynchronous motor control profile | Constant torque standard<br />Optimized torque mode<br />Variable torque standard |
Synchronous motor control profile | Permanent magnet motor<br />Synchronous reluctance motor | Speed drive output frequency | 0.1…500 Hz |
Nominal switching frequency | 2.5 kHz | Switching frequency | 2.5...8 kHz with derating factor<br />2...8 kHz adjustable |
Safety function | STO (safe torque off) SIL 3 | Discrete input logic | Positive logic (source) DI1...DI8), < 5 V, > 11 V<br />Negative logic (sink) DI1...DI8), > 16 V, < 10 V |
communication port protocol | Modbus TCP<br />Ethernet<br />Modbus serial | Option card | Slot A communication module, Profibus DP V1<br />Slot A communication module, PROFINET<br />Slot A communication module, DeviceNet<br />Slot A communication module, Modbus TCP/EtherNet/IP<br />Slot A communication module, CANopen daisy chain RJ45<br />Slot A communication module, CANopen SUB-D 9<br />Slot A communication module, CANopen screw terminals<br />Slot A/slot B digital and analog I/O extension module<br />Slot A/slot B output relay extension module<br />Slot A communication module, Ethernet IP/Modbus TCP/MD-Link<br /> communication module, BACnet MS/TP<br /> communication module, Ethernet Powerlink |
Mounting Mode | Wall mount | Maximum transient current | 232.1 A 60 s normal duty)<br />259.5 A 60 s heavy duty) |
Phase | 3 phase | Discrete output number | 0 |
Discrete output type | Relay outputs R1A, R1B, R1C 250 V AC 3000 mA<br />Relay outputs R1A, R1B, R1C 30 V DC 3000 mA<br />Relay outputs R2A, R2C 250 V AC 5000 mA<br />Relay outputs R2A, R2C 30 V DC 5000 mA<br />Relay outputs R3A, R3C 250 V AC 5000 mA<br />Relay outputs R3A, R3C 30 V DC 5000 mA | Output voltage | <= power supply voltage |
Permissible temporary current boost | 1.1 x In 60 s normal duty)<br />1.5 x In 60 s heavy duty) | Motor slip compensation | Can be suppressed<br />Not available in permanent magnet motor law<br />Automatic whatever the load<br />Adjustable |
Acceleration and deceleration ramps | Linear adjustable separately from 0.01...9999 s | Physical interface | Ethernet<br />2-wire RS 485 |
Braking to standstill | By DC injection | Protection type | Thermal protection motor<br />Safe torque off motor<br />Motor phase break motor<br />Thermal protection drive<br />Safe torque off drive<br />Overheating drive<br />Overcurrent between output phases and earth drive<br />Overload of output voltage drive<br />Short-circuit protection drive<br />Motor phase break drive<br />Overvoltages on the DC bus drive<br />Line supply overvoltage drive<br />Line supply undervoltage drive<br />Line supply phase loss drive<br />Overspeed drive<br />Break on the control circuit drive |
Transmission Rate | 10, 100 Mbits<br />4800 bps, 9600 bps, 19200 bps, 38.4 Kbps | Frequency resolution | Display unit 0.1 Hz<br />Analog input 0.012/50 Hz |
Transmission frame | RTU | Electrical connection | Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16<br />Line side screw terminal 2 x 50...3 x 120 mm² 2 x AWG 1/0...2 x 300 kcmil<br />Motor screw terminal 2 x 50...3 x 120 mm² 2 x AWG 1/0...2 x 300 kcmil |
Connector type | RJ45 on the remote graphic terminal)Ethernet/Modbus TCP<br />RJ45 on the remote graphic terminal)Modbus serial | Data format | 8 bits, configurable odd, even or no parity |
Type of polarization | No impedance | Exchange mode | Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
Number of addresses | 1…247 Modbus serial | Method of access | Slave Modbus TCP |
Supply | External supply for digital inputs 24 V DC 19…30 V), <1.25 mA overload and short-circuit protection<br />Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection<br />Internal supply for digital inputs and STO 24 V DC 21…27 V), <200 mA overload and short-circuit protection | Local signalling | for local diagnostic 3 LEDs<br /> for embedded communication status 3 LEDs (dual colour)<br /> for communication module status 4 LEDs (dual colour)<br /> for presence of voltage 1 LED (red) |
Width | 12.6 in (320 mm) | Height | 33.5 in (852 mm) |
Depth | 15.4 in (390 mm) | Net Weight | 180.8 lb(US) (82 kg) |
Analogue input number | 3 | Analogue input type | AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits<br />AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits<br />AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits |
Discrete input number | 8 | Discrete input type | DI7, DI8 programmable as pulse input 0…30 kHz, 24 V DC <= 30 V) |
Input compatibility | DI1...DI6 discrete input level 1 PLC IEC 61131-2<br />DI5, DI6 discrete input level 1 PLC IEC 65A-68<br />STOA, STOB discrete input level 1 PLC IEC 61131-2 | Analogue output number | 2 |
Analogue output type | Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits<br />Software-configurable current AQ1, AQ2 0...20 mA 10 bits<br />Software-configurable current DQ-, DQ+ 30 V DC<br />Software-configurable current DQ-, DQ+ 100 mA | Sampling duration | 2 ms +/- 0.5 ms DI1...DI4) - discrete input<br />5 ms +/- 1 ms DI5, DI6) - discrete input<br />5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input<br />10 ms +/- 1 ms AO1) - analog output |
Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input<br />+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output | Linearity error | AI1, AI2, AI3 +/- 0.15 % of maximum value analog input<br />AO1, AO2 +/- 0.2 % analog output |
Relay output number | 3 | Relay output type | Configurable relay logic R1 fault relay NO/NC 100000 cycles<br />Configurable relay logic R2 sequence relay NO 100000 cycles<br />Configurable relay logic R3 sequence relay NO 100000 cycles |
Refresh time | Relay output R1, R2, R3)5 ms +/- 0.5 ms) | Minimum switching current | Relay output R1, R2, R3 5 mA 24 V DC |
Maximum switching current | Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC<br />Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC<br />Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC | Isolation | Between power and control terminals |
Maximum output frequency | 500 kHz | Maximum Input Current per Phase | 201.0 A |
Variable speed drive application selection | Building - HVAC compressor centrifugal<br />Food and beverage processing other application<br />Mining mineral and metal fan<br />Mining mineral and metal pump<br />Oil and gas fan<br />Water and waste water other application<br />Building - HVAC screw compressor<br />Food and beverage processing pump<br />Food and beverage processing fan<br />Food and beverage processing atomization<br />Oil and gas electro submersible pump (ESP)<br />Oil and gas water injection pump<br />Oil and gas jet fuel pump<br />Oil and gas compressor for refinery<br />Water and waste water centrifuge pump<br />Water and waste water positive displacement pump<br />Water and waste water electro submersible pump (ESP)<br />Water and waste water screw pump<br />Water and waste water lobe compressor<br />Water and waste water screw compressor<br />Water and waste water compressor centrifugal<br />Water and waste water fan<br />Water and waste water conveyor<br />Water and waste water mixer | Motor power range AC-3 | 110…220 kW 380…440 V 3 phase<br />110…220 kW 480…500 V 3 phase |
Quantity per Set | 1 | enclosure mounting | Wall mounted |
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth | Noise level | 69.9 dB |
Power dissipation in W | Forced convection 2026 W 380 V 2.5 kHz | Volume of cooling air | 158506.07 Gal/hr(US) (600 m3/h) |
Operating position | Vertical +/- 10 degree | Maximum THDI | <48 % full load IEC 61000-3-12 |
Electromagnetic compatibility | Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test level 3 IEC 61000-4-6 | Pollution degree | 2 |
Vibration resistance | 1.5 mm peak to peak 2…13 Hz)IEC 60068-2-6<br />1 gn 13…200 Hz)IEC 60068-2-6 | Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
Relative humidity | 5…95 % without condensation IEC 60068-2-3 | Ambient air temperature for operation | 5…122 °F (-15…50 °C) without derating)<br />122…140 °F (50…60 °C) with derating factor) |
Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) | Operating altitude | <= 3280.84 ft (1000 m) without derating<br />1000...4800 m with current derating 1 % per 100 m |
Product Certifications | ATEX zone 2/22<br />ATEX INERIS<br />TÜV<br />CSA<br />UL<br />DNV-GL | Marking | CE |
Standards | UL 508C<br />IEC 61800-3<br />IEC 61800-3 environment 1 category C2<br />EN/IEC 61800-3 environment 2 category C3<br />IEC 61800-5-1<br />IEC 61000-3-12<br />IEC 60721-3<br />IEC 61508<br />IEC 13849-1 | Overvoltage category | III |
Regulation loop | Adjustable PID regulator |
Specifications may be subject to change without notice