Product Model
ATV71HD15N4Z

Selling Points
- 120HP for demanding industrial applications.
- 2Compatible with 460V, ensuring versatility in various settings.
- 3Made from 90% recyclable materials, compliant with environmental standards.
- 4Power Removal safety function to prevent accidental restarts and ensure motor stopping.
- 5Meets IEC/EN 61800-5-1, IEC/EN 61800-2, IEC/EN 61800-3, UL, CSA, DNV, C-Tick, NOM 117, and GOST certifications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Altivar 71 | Product or Component Type | Variable speed drive |
Product Specific Application | Complex, high-power machines | Component name | ATV71 |
Motor power kW | 15 kW, 3 phase 380...480 V | Maximum Horse Power Rating | 20 hp, 3 phase 380...480 V |
Maximum motor cable length | 164.04 ft (50 m) shielded cable<br />328.08 ft (100 m) unshielded cable | power supply voltage | 380...480 V - 15...10 % |
Phase | 3 phase | Line current | 39 A 480 V 3 phase 15 kW / 20 hp<br />48 A 380 V 3 phase 15 kW / 20 hp |
EMC filter | Integrated | Assembly style | With heat sink |
Variant | Without remote graphic terminal | Apparent power | 31.6 kVA 380 V 3 phase 15 kW / 20 hp |
Prospective line Isc | 22 kA 3 phase | Nominal output current | 27 A 4 kHz 460 V 3 phase 15 kW / 20 hp<br />33 A 4 kHz 380 V 3 phase 15 kW / 20 hp |
Maximum transient current | 49.5 A 60 s 3 phase 15 kW / 20 hp<br />54.5 A 2 s 3 phase 15 kW / 20 hp | Output frequency | 0.1…599 Hz |
Nominal switching frequency | 4 kHz | Switching frequency | 1...16 kHz adjustable<br />4...16 kHz with derating factor |
Asynchronous motor control profile | Voltage/frequency ratio (2 or 5 points)<br />ENA (Energy adaptation) system for unbalanced loads<br />Sensorless flux vector control (SFVC) (voltage or current vector)<br />Flux vector control (FVC) with sensor (current vector) | Type of polarization | No impedance Modbus |
Product destination | Asynchronous motors<br />Synchronous motors | power supply voltage limits | 323…528 V |
power supply frequency | 50...60 Hz - 5...5 % | power supply frequency limits | 47.5...63 Hz |
Speed range | 1…100 asynchronous motor in open-loop mode, without speed feedback<br />1…1000 asynchronous motor in closed-loop mode with encoder feedback<br />1…50 synchronous motor in open-loop mode, without speed feedback | Speed accuracy | +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn<br />+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn |
Torque accuracy | +/- 15 % in open-loop mode, without speed feedback<br />+/- 5 % in closed-loop mode with encoder feedback | Transient overtorque | 170 % +/- 10 % 60 s every 10 minutes<br />220 % +/- 10 % 2 s |
Braking torque | <= 150 % with braking or hoist resistor<br />30 % without braking resistor | Synchronous motor control profile | Vector control without speed feedback |
Regulation loop | Adjustable PI regulator | Motor slip compensation | Adjustable<br />Not available in voltage/frequency ratio (2 or 5 points)<br />Automatic whatever the load<br />Suppressable |
diagnostic | for drive voltage 1 LED (red) | Output voltage | <= power supply voltage |
Insulation | Electrical between power and control | type of cable for mounting in an enclosure | With a NEMA Type1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC<br />With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC<br />Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC<br />Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR |
Electrical connection | Terminal 2.5 mm², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)<br />Terminal 35 mm², AWG 2 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) | Tightening torque | 5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)<br />47.8 lbf.in (5.4 N.m), 47.7 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
Supply | Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection<br />Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection | Analogue input number | 2 |
Analogue input type | AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign<br />AI2 software-configurable current 0...20 mA 242 Ohm 11 bits<br />AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits | input sampling time | 2 ms +/- 0.5 ms AI1-/Al1+) - analog<br />2 ms +/- 0.5 ms Al2) - analog<br />2 ms +/- 0.5 ms LI1...LI5) - discrete<br />2 ms +/- 0.5 ms LI6)if configured as logic input - discrete |
Response time | <= 100 ms in STO (Safe Torque Off)<br />AO1 2 ms +/- 0.5 ms analog<br />R1A, R1B, R1C 7 ms +/- 0.5 ms discrete<br />R2A, R2B 7 ms +/- 0.5 ms discrete | absolute accuracy precision | +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C<br />+/- 0.6 % AI2) for a temperature variation 60 °C<br />+/- 1 % AO1) for a temperature variation 60 °C |
Linearity error | +/- 0.15 % of maximum value AI1-/Al1+, AI2)<br />+/- 0.2 % AO1) | Analogue output number | 1 |
Analogue output type | AO1 software-configurable logic output 10 V 20 mA<br />AO1 software-configurable current 0...20 mA 500 Ohm 10 bits<br />AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits | Discrete output number | 2 |
Discrete output type | Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles<br />Configurable relay logic R2A, R2B) NO - 100000 cycles | Minimum switching current | 3 mA 24 V DC configurable relay logic |
Maximum switching current | R1, R2 2 A 250 V AC inductive, cos phi = 0.4<br />R1, R2 2 A 30 V DC inductive, cos phi = 0.4<br />R1, R2 5 A 250 V AC resistive, cos phi = 1<br />R1, R2 5 A 30 V DC resistive, cos phi = 1 | Discrete input number | 7 |
Discrete input type | LI1...LI5 programmable 24 V DC level 1 PLC 3500 Ohm<br />LI6 switch-configurable 24 V DC level 1 PLC 3500 Ohm<br />LI6 switch-configurable PTC probe 0…6 1500 Ohm<br />PWR safety input 24 V DC 1500 Ohm ISO 13849-1 level d | Discrete input logic | Negative logic (sink) LI1...LI5), > 16 V, < 10 V<br />Positive logic (source) LI1...LI5), < 5 V, > 11 V<br />Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V<br />Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V |
Acceleration and deceleration ramps | S, U or customized<br />Linear adjustable separately from 0.01 to 9000 s<br />Automatic adaptation of ramp if braking capacity exceeded, by using resistor | Braking to standstill | By DC injection |
Protection type | Against exceeding limit speed drive<br />Against input phase loss drive<br />Break on the control circuit drive<br />Input phase breaks drive<br />Line supply overvoltage drive<br />Line supply undervoltage drive<br />Overcurrent between output phases and earth drive<br />Overheating protection drive<br />Overvoltages on the DC bus drive<br />Short-circuit between motor phases drive<br />Thermal protection drive<br />Motor phase break motor<br />Power removal motor<br />Thermal protection motor | Insulation resistance | > 1 mOhm 500 V DC for 1 minute to earth |
Frequency resolution | Analog input 0.024/50 Hz<br />Display unit 0.1 Hz | communication port protocol | CANopen<br />Modbus |
Connector type | 1 RJ45 on front face)Modbus<br />1 RJ45 on terminal)Modbus<br />Male SUB-D 9 on RJ45CANopen | Physical interface | 2-wire RS 485 Modbus |
Transmission frame | RTU Modbus | Transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal<br />9600 bps, 19200 bps Modbus on front face<br />20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen |
Data format | 8 bits, 1 stop, even parity Modbus on front face<br />8 bits, odd even or no configurable parity Modbus on terminal | Number of addresses | 1…127 CANopen<br />1…247 Modbus |
Method of access | Slave CANopen | marking | CE |
Operating position | Vertical +/- 10 degree | Height | 15.7 in (400 mm) |
Depth | 8.4 in (213 mm) | Width | 9.06 in (230 mm) |
Net Weight | 28.7 lb(US) (13 kg) | Option card | Communication card CC-Link<br />Controller inside programmable card<br />Communication card DeviceNet<br />Communication card EtherNet/IP<br />Communication card Fipio<br />I/O extension card<br />Communication card Interbus-S<br />Interface card for encoder<br />Communication card Modbus Plus<br />Communication card Modbus TCP<br />Communication card Modbus/Uni-Telway<br />Overhead crane card<br />Communication card Profibus DP<br />Communication card Profibus DP V1 |
Noise level | 60.2 dB 86/188/EEC | Dielectric strength | 3535 V DC between earth and power terminals<br />5092 V DC between control and power terminals |
Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test level 3 IEC 61000-4-6<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Voltage dips and interruptions immunity test IEC 61000-4-11 | Standards | IEC 61800-3 environments 1 category C3<br />IEC 61800-3 environments 2 category C3<br />IEC 60721-3-3 class 3C1<br />IEC 61800-5-1<br />IEC 60721-3-3 class 3S2<br />EN 55011 class A group 2<br />UL Type 1<br />IEC 61800-3 |
Product Certifications | CSA<br />UL<br />C-tick<br />NOM 117<br />GOST | Pollution degree | 2 IEC 61800-5-1 |
IP degree of protection | IP20 on upper part without blanking plate on cover IEC 60529<br />IP20 on upper part without blanking plate on cover IEC 61800-5-1<br />IP21 IEC 60529<br />IP21 IEC 61800-5-1<br />IP41 on upper part IEC 60529<br />IP41 on upper part IEC 61800-5-1<br />IP54 on lower part IEC 60529<br />IP54 on lower part IEC 61800-5-1 | Vibration resistance | 1 gn 13…200 Hz)IEC 60068-2-6<br />1.5 mm peak to peak 3…13 Hz)IEC 60068-2-6 |
Shock resistance | 15 gn 11 ms IEC 60068-2-27 | Relative humidity | 5…95 % without condensation IEC 60068-2-3<br />5…95 % without dripping water IEC 60068-2-3 |
Ambient air temperature for operation | 14…122 °F (-10…50 °C) without derating) | Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Operating altitude | <= 3280.84 ft (1000 m) without derating<br />3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m |
Specifications may be subject to change without notice