Product Model
BMXDDM16025

Selling Points
- 1High-Quality Construction: Built with robust materials for long-lasting performance in harsh industrial environments.
- 2Versatile Connectivity: Compatible with Modicon M580 and M340 Programmable Automation Controllers (PAC).
- 3Advanced Technical Specifications: 8 discrete inputs (24 V DC), 8 relay outputs (24-240 V AC), 3.1 W power rating, and 7 ms conversion rate.
- 4Wide Application Range: Suitable for various industries including waste water treatment, mining, and food and beverage.
- 5Comprehensive Certification: Meets EN 61131-2, EN 61000-6-4, EN 61000-6-2, and EN 61010-2-201 standards, ensuring reliability and safety.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range of Product | Modicon X80 | Product or Component Type | Discrete I/O module |
Discrete input number | 8 | input type | Current sink (logic positive) |
Discrete input voltage | 24 V DC positive | Discrete input current | 3.5 mA |
Discrete output number | 8 | Discrete output type | Relay |
Discrete output voltage | 24 V 19...30 V DC<br />24...240 V 19...264 V AC | Discrete output current | 2000 mA |
Input compatibility | With 2-wire/3-wire proximity sensors IEC 60947-5-2<br />With 2-wire/3-wire proximity sensors IEC 61131-2 type 3 | Sensor power supply | 19...30 V |
Current state 1 guaranteed | >= 2 mA | Current state 0 guaranteed | <= 1.5 mA |
input impedance | 6800 Ohm | Insulation resistance | > 10 MOhm 500 V DC |
Power dissipation in W | 3.1 W | DC typical response time | 4 ms |
DC maximum response time | 7 ms | Response time on output | <= 8 ms deactivation<br /><= 10 ms activation |
Paralleling of inputs | No | Typical current consumption | 79 mA 3.3 V DC |
MTBF reliability | 940000 H | Protection type | 1 external fuse per group of input channel 0.5 A fast blow<br /> reverse polarity protection on input<br /> 1 external fuse per output channel or group of output channel fast blow |
Voltage detection threshold | < 14 V DC sensor fault<br />> 18 V DC sensor OK | Minimum switching current | 1 mA 5 V DC |
Maximum switching voltage | 125 V DC<br />264 V AC | Mechanical durability | 20000000 cycles |
Electrical durability | AC-14 100000 cycles 240 VA 240 V 0.7)<br />AC-14 100000 cycles 300 VA 200 V 0.7)<br />AC-15 100000 cycles 120 VA 240 V 0.35)<br />AC-15 100000 cycles 200 VA 200 V 0.35)<br />DC-13 100000 cycles 24 W 24 V<br />AC-14 300000 cycles 72 VA 240 V 0.7)<br />AC-14 300000 cycles 80 VA 200 V 0.7)<br />AC-15 300000 cycles 36 VA 240 V 0.35)<br />AC-15 300000 cycles 60 VA 200 V 0.35)<br />DC-13 300000 cycles 7.2 W 24 V | Switching frequency | 1 Hz |
Status LED | 1 LED (Green) module operating (RUN)<br />1 LED per channel (Green) channel diagnostic<br />1 LED (Red) module error (ERR)<br />1 LED (Red) module I/O | Net Weight | 0.298 lb(US) (0.135 kg) |
IP Degree of Protection | IP20 | Directives | 2014/35/EU - low voltage directive<br />2014/30/EU - electromagnetic compatibility |
Dielectric strength | 1500 V AC 50/60 Hz 1 minute, primary/secondary<br />2830 V AC 50/60 Hz 1 minute, output relay<br />500 V DC 1 minute, between group of I/O | Vibration resistance | 3 gn |
Shock resistance | 30 gn | Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
Ambient Air Temperature for Operation | 32…140 °F (0…60 °C) | Relative humidity | 5…95 % 131 °F (55 °C) without condensation |
Operating altitude | 0...6561.68 ft (0...2000 m)<br />2000...5000 m with derating factor |
Specifications may be subject to change without notice