Selling Points

  • 1High reliability with long mechanical and electrical life.
  • 2Efficient operation with up to 80% less consumption than standard coils.
  • 3Robust specifications including 200 A contact rating and 4NO configuration.
  • 4Easy installation with screw clamp connections and IP20 finger-safe terminals.
  • 5Compatible with 50/60 Hz frequency and suitable for resistive loads up to 200 amps.
Product Details
LC1D115004T7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC-1<br />AC-3<br />AC-3e<br />AC-4
Poles description
4P
[Ue] rated operational voltage
Power circuit <= 1000 V AC 25...400 Hz<br />Power circuit <= 460 V DC
[Ie] rated operational current
200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage
480 V AC 50/60 Hz
compatibility code
LC1D
Pole contact composition
4 NO
Protective cover
With
[Ith] conventional free air thermal current
200 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
1260 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
250 A 104 °F (40 °C) - 10 min for power circuit<br />550 A 104 °F (40 °C) - 1 min for power circuit<br />950 A 104 °F (40 °C) - 10 s for power circuit<br />1100 A 104 °F (40 °C) - 1 s for power circuit
Associated fuse rating
250 A gG at <= 690 V coordination type 1 for power circuit<br />200 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Power dissipation per pole
24 W AC-1
[Ui] rated insulation voltage
Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1
Overvoltage category
III
Pollution degree
3
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
Safety reliability level
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
8 Mcycles
Electrical durability
0.8 Mcycles 200 A AC-1 <= 440 V
Control circuit type
AC 50/60 Hz
Coil technology
Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.3...0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz<br />1...1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
Inrush power in VA
280…350 VA 60 Hz cos phi 0.8 (at 68 °F (20 °C))<br />280…350 VA 50 Hz cos phi 0.8 (at 68 °F (20 °C))
Hold-in power consumption in VA
2…18 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))<br />2…18 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation
3…8 W at 50/60 Hz
Operating time
6...20 ms opening<br />20...50 ms closing
Maximum operating rate
2400 cyc/h 140 °F (60 °C)
Connections - terminals
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: solid without cable end
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2<br />Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)
Mounting Support
Rail<br />Plate
Standards
CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508
Product Certifications
LROS (Lloyds register of shipping)<br />BV<br />RINA<br />DNV<br />CSA<br />GL<br />CCC<br />GOST<br />UL
IP degree of protection
IP20 front face IEC 60529
Protective treatment
THIEC 60068-2-30
Climatic withstand
IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device
-40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) <br />Shocks contactor closed 15 Gn for 11 ms) <br />Shocks contactor open 6 Gn for 11 ms)
Height
6.2 in (158 mm)
Width
5.9 in (150 mm)
Depth
5.2 in (132 mm)
Net Weight
6.31 lb(US) (2.86 kg)

Specifications may be subject to change without notice