schneider LC1D1156GD

Selling Points

  • 1Designed for long mechanical and electrical life.
  • 2Suitable for inductive motor applications up to 150A and resistive loads up to 200A.
  • 3Includes auxiliary contact blocks with serrated wiping action for easy installation.
  • 4Provides overload protection for motors rated up to 100 HP at 480 VAC or 125 HP at 600 VAC.
  • 5Constructed with high-quality materials for consistent performance in demanding environments.
Product Details
LC1D1156GD
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Motor control<br />Resistive load
Utilisation category
AC-1<br />AC-4<br />AC-3<br />AC-3e
Poles description
3P
[Ue] rated operational voltage
Power circuit <= 1000 V AC 25...400 Hz<br />Power circuit <= 300 V DC
[Ie] rated operational current
200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />115 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />115 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
125 V DC
Motor power kW
30 kW at 220...230 V AC 50/60 Hz (AC-3)<br />55 kW at 380...400 V AC 50/60 Hz (AC-3)<br />59 kW at 415...440 V AC 50/60 Hz (AC-3)<br />75 kW at 500 V AC 50/60 Hz (AC-3)<br />80 kW at 660...690 V AC 50/60 Hz (AC-3)<br />65 kW at 1000 V AC 50/60 Hz (AC-3)<br />18.5 kW at 400 V AC 50/60 Hz (AC-4)<br />30 kW at 220...230 V AC 50/60 Hz (AC-3e)<br />55 kW at 380...400 V AC 50/60 Hz (AC-3e)<br />59 kW at 415...440 V AC 50/60 Hz (AC-3e)<br />75 kW at 500 V AC 50/60 Hz (AC-3e)<br />80 kW at 660...690 V AC 50/60 Hz (AC-3e)<br />65 kW at 1000 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating
30 hp at 200/208 V AC 50/60 Hz for 3 phase motors<br />40 hp at 230/240 V AC 50/60 Hz for 3 phase motors<br />75 hp at 460/480 V AC 50/60 Hz for 3 phase motors<br />100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
compatibility code
LC1D
Pole contact composition
3 NO
Protective cover
With
[Ith] conventional free air thermal current
200 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
1260 A at 440 V for power circuit conforming to IEC 60947<br />140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
250 A 104 °F (40 °C) - 10 min for power circuit<br />550 A 104 °F (40 °C) - 1 min for power circuit<br />950 A 104 °F (40 °C) - 10 s for power circuit<br />1100 A 104 °F (40 °C) - 1 s for power circuit<br />100 A - 1 s for signalling circuit<br />120 A - 500 ms for signalling circuit<br />140 A - 100 ms for signalling circuit
Associated fuse rating
250 A gG at <= 690 V coordination type 1 for power circuit<br />200 A gG at <= 690 V coordination type 2 for power circuit<br />10 A gG for signalling circuit
Average impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Power dissipation per pole
24 W AC-1<br />7.9 W AC-3<br />7.9 W AC-3e
[Ui] rated insulation voltage
Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-1<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL
Overvoltage category
III
Pollution degree
3
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
Safety reliability level
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
8 Mcycles
Electrical durability
0.8 Mcycles 200 A AC-1 <= 440 V<br />0.95 Mcycles 115 A AC-3 <= 440 V<br />0.95 Mcycles 115 A AC-3e <= 440 V
Control circuit type
DC standard
Coil technology
With integral suppression device
Control circuit voltage limits
0.75...1.2 Uc -40…131 °F (-40…55 °C) operational DC<br />0.15...0.4 Uc -40…158 °F (-40…70 °C) drop-out DC<br />1...1.2 Uc 131…158 °F (55…70 °C) operational DC
Inrush power in W
270…365 W 68 °F (20 °C))
Hold-in power consumption in W
2.4…5.1 W 68 °F (20 °C)
Operating time
20...35 ms closing<br />40...75 ms opening
Time constant
25 ms
Maximum operating rate
1200 cyc/h 140 °F (60 °C)
Connections - terminals
Control circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm)<br />Power circuit: lugs-ring terminals - external diameter: 1.0 in (25 mm)<br />Power circuit: bars 1 - busbar cross section: 5 x 25 mm
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals flat Ø 6 mm M3.5<br />Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals Philips No 2 M3.5<br />Power circuit 106.2 lbf.in (12 N.m) lugs-ring terminals hexagonal 0.5 in (13 mm) M8<br />Power circuit 106.2 lbf.in (12 N.m) bars hexagonal 0.5 in (13 mm) M8
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency
25...400 Hz
Minimum switching voltage
17 V for signalling circuit
Minimum switching current
5 mA for signalling circuit
Insulation resistance
> 10 MOhm for signalling circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact
Mounting Support
Plate<br />Rail
Standards
CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508
Product Certifications
UL<br />CSA<br />CCC<br />GL<br />LROS (Lloyds register of shipping)<br />BV<br />GOST<br />RINA<br />DNV<br />UKCA<br />CE
IP degree of protection
IP20 front face IEC 60529
Protective treatment
THIEC 60068-2-30
Climatic withstand
IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device
-40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) <br />Shocks contactor closed 15 Gn for 11 ms) <br />Shocks contactor open 6 Gn for 11 ms)
Height
6.2 in (158 mm)
Width
4.7 in (120 mm)
Depth
5.4 in (136 mm)
Net Weight
5.5 lb(US) (2.5 kg)