schneider LC1D40004G6

Selling Points

  • 1High Current Rating: 60A resistive load rating for reliable operation.
  • 2Versatile Mounting: Compatible with DIN rail or panel mounting for flexible installation.
  • 3Efficient Coil: 120 VAC 60 Hz coil for efficient control circuit operation.
  • 4Robust Construction: Certified to UL, CSA, IEC, CCC, EAC, and Marine standards for safety and reliability.
  • 5Green Premium Product: Meets RoHS/REACh requirements, making it a Green Premium product with reduced energy consumption.
Product Details
LC1D40004G6
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC-1<br />AC-3<br />AC-3e<br />AC-4
Poles description
4P
[Ue] rated operational voltage
Power circuit 690 V AC 25...400 Hz
[Ie] rated operational current
60 A (at <140 °F (60 °C)) at 440 V AC AC-1 for power circuit
[Uc] control circuit voltage
120 V AC 60 Hz
compatibility code
LC1D
Pole contact composition
4 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for control circuit<br />40 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
140 A AC for control circuit conforming to IEC 60947-5-1<br />800 A at 440 V AC for power circuit conforming to IEC 60947
Rated breaking capacity
800 kA at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1<br />80 A at 690 V coordination type 1 for power circuit<br />80 A at 690 V coordination type 2 for power circuit
Average impedance
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole
5.4 W AC-1<br />2.4 W AC-3
[Ui] rated insulation voltage
Control circuit 600 V CSA<br />Control circuit 600 V UL<br />Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Control circuit 690 V IEC 60947-4-1<br />Power circuit 690 V IEC 60947-4-1
Overvoltage category
III
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
15000000 cycles
Control circuit type
AC 60 Hz standard
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.3...0.6 Uc 140 °F (60 °C) drop-out AC 50/60 Hz<br />0.85...1.1 Uc 140 °F (60 °C) operational AC 60 Hz
Inrush power in VA
140 VA cos phi 0.75 (at 68 °F (20 °C))
Heat dissipation
2…3 W at 50/60 Hz for control circuit
Operating time
12...22 ms closing<br />4...19 ms opening
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Connections - terminals
Control circuit: screw clamp terminal 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminal 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminal 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Power circuit: screw clamp terminal 1 0.004…0.02 in² (2.5…16 mm²) - cable stiffness: solid without cable end<br />Power circuit: screw clamp terminal 2 0.004…0.02 in² (2.5…16 mm²) - cable stiffness: solid without cable end
Tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ø 6 mm hexagonal<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal Philips No 2 hexagonal<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal pozidriv No 2
Auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1
Minimum switching voltage
17 V for control circuit
Minimum switching current
5 mA for control circuit
Insulation resistance
> 10 MOhm for control circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contacts<br />1.5 ms on energisation between NC and NO contacts
Mounting Support
Plate<br />Rail
Standards
CSA C22.2 No 14<br />EN/IEC 60947-5-1<br />UL 508<br />EN/IEC 60947-4-1
Product Certifications
CSA<br />DNV<br />GL<br />BV<br />UL<br />CCC<br />RINA<br />LROS (Lloyds register of shipping)<br />UKCA
IP degree of protection
IP2X VDE 0106
Protective treatment
THIEC 60068-2-30
Permissible ambient air temperature around the device
23…140 °F (-5…60 °C)<br />-40…158 °F (-40…70 °C) at Uc
Operating altitude
9842.52 ft (3000 m) without derating
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Shocks contactor open 8 Gn for 11 ms) <br />Shocks contactor closed 10 Gn for 11 ms) <br />Vibrations contactor opened 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz)

Specifications may be subject to change without notice