schneider LC1D40G7M

Selling Points

  • 1High Operational Current: Handles up to 40A at 440V AC for AC-3 applications.
  • 2Versatile Coil Voltage: Compatible with 120V AC 50/60Hz coils for efficient control.
  • 3Durable Design: Meets mechanical durability standards with 6 million operating cycles.
  • 4Safety Features: Compliant with EN/ISO 13849-1 for high safety reliability.
  • 5Easy Installation: Features screw clamp terminals for straightforward mounting.
Product Details
LC1D40G7M
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load<br />Motor control
Utilisation category
AC-1<br />AC-4<br />AC-3<br />AC-3e
Poles description
3P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current
60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
120 V AC 50/60 Hz
Motor power kW
18.5 kW at 380...400 V AC 50/60 Hz (AC-3)<br />22 kW at 500 V AC 50/60 Hz (AC-3)<br />30 kW at 660...690 V AC 50/60 Hz (AC-3)<br />22 kW at 1000 V AC 50/60 Hz (AC-3)<br />22 kW at 415 V AC 50/60 Hz (AC-3)<br />22 kW at 440 V AC 50/60 Hz (AC-3)<br />11 kW at 220...230 V AC 50/60 Hz (AC-3)<br />9 kW at 400 V AC 50/60 Hz (AC-4)<br />18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)<br />22 kW at 500 V AC 50/60 Hz (AC-3e)<br />30 kW at 660...690 V AC 50/60 Hz (AC-3e)<br />22 kW at 1000 V AC 50/60 Hz (AC-3e)<br />22 kW at 415 V AC 50/60 Hz (AC-3e)<br />22 kW at 440 V AC 50/60 Hz (AC-3e)<br />11 kW at 220...230 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating
10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA<br />10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL<br />10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA<br />10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL<br />5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA<br />5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL<br />3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA<br />3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL<br />30 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA<br />30 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL<br />30 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA<br />30 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL
compatibility code
LC1D
Pole contact composition
3 NO
Protective cover
Without
[Ith] conventional free air thermal current
60 A (at 140 °F (60 °C)) for power circuit<br />10 A (at 140 °F (60 °C)) for signalling circuit
Irms rated making capacity
800 A at 440 V for power circuit conforming to IEC 60947<br />140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity
800 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
80 A gG at <= 690 V coordination type 1 for power circuit<br />80 A gG at <= 690 V coordination type 2 for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947-5-1
Power dissipation per pole
5.4 W AC-1<br />2.4 W AC-3<br />2.4 W AC-3e
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1<br />Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL<br />Signalling circuit 690 V IEC 60947-1
Overvoltage category
III
Pollution degree
3
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
6 Mcycles
Control circuit type
AC 50/60 Hz
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz<br />0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz<br />1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
Inrush power in VA
160 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))<br />140 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA
15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))<br />13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation
4…5 W at 50/60 Hz
Operating time
4...19 ms opening<br />12...26 ms closing
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Connections - terminals
Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw clamp terminals 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw clamp terminals 2 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw clamp terminals 2 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid
Tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ø 6 to Ø 8 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency
25...400 Hz
Minimum switching voltage
17 V for signalling circuit
Minimum switching current
5 mA for signalling circuit
Insulation resistance
> 10 MOhm for signalling circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact
Mounting Support
Plate<br />Rail
Standards
CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508
Product Certifications
BV<br />CCC<br />CSA<br />DNV<br />GL<br />LROS (Lloyds register of shipping)<br />UL<br />GOST<br />RINA<br />UKCA
Climatic withstand
IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device
-40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 3 Gn, 5...300 Hz) <br />Shocks contactor open 8 Gn for 11 ms) <br />Shocks contactor closed 10 Gn for 11 ms)
Height
5.0000000000 in (127 mm)
Width
3.0 in (75 mm)
Depth
4.7 in (119 mm)
Net Weight
3.09 lb(US) (1.4 kg)

Specifications may be subject to change without notice