Product Model
LC1D40G7M

Selling Points
- 1High Operational Current: Handles up to 40A at 440V AC for AC-3 applications.
- 2Versatile Coil Voltage: Compatible with 120V AC 50/60Hz coils for efficient control.
- 3Durable Design: Meets mechanical durability standards with 6 million operating cycles.
- 4Safety Features: Compliant with EN/ISO 13849-1 for high safety reliability.
- 5Easy Installation: Features screw clamp terminals for straightforward mounting.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Range of Product | TeSys Deca |
Product or Component Type | Contactor | Device short name | LC1D |
Contactor application | Resistive load<br />Motor control | Utilisation category | AC-1<br />AC-4<br />AC-3<br />AC-3e |
Poles description | 3P | [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz |
[Ie] rated operational current | 60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />40 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit | [Uc] control circuit voltage | 120 V AC 50/60 Hz |
Motor power kW | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)<br />22 kW at 500 V AC 50/60 Hz (AC-3)<br />30 kW at 660...690 V AC 50/60 Hz (AC-3)<br />22 kW at 1000 V AC 50/60 Hz (AC-3)<br />22 kW at 415 V AC 50/60 Hz (AC-3)<br />22 kW at 440 V AC 50/60 Hz (AC-3)<br />11 kW at 220...230 V AC 50/60 Hz (AC-3)<br />9 kW at 400 V AC 50/60 Hz (AC-4)<br />18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)<br />22 kW at 500 V AC 50/60 Hz (AC-3e)<br />30 kW at 660...690 V AC 50/60 Hz (AC-3e)<br />22 kW at 1000 V AC 50/60 Hz (AC-3e)<br />22 kW at 415 V AC 50/60 Hz (AC-3e)<br />22 kW at 440 V AC 50/60 Hz (AC-3e)<br />11 kW at 220...230 V AC 50/60 Hz (AC-3e) | Maximum Horse Power Rating | 10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA<br />10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL<br />10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA<br />10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL<br />5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA<br />5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL<br />3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA<br />3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL<br />30 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA<br />30 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL<br />30 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA<br />30 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL |
compatibility code | LC1D | Pole contact composition | 3 NO |
Protective cover | Without | [Ith] conventional free air thermal current | 60 A (at 140 °F (60 °C)) for power circuit<br />10 A (at 140 °F (60 °C)) for signalling circuit |
Irms rated making capacity | 800 A at 440 V for power circuit conforming to IEC 60947<br />140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1 | Rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
Associated fuse rating | 80 A gG at <= 690 V coordination type 1 for power circuit<br />80 A gG at <= 690 V coordination type 2 for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947-5-1 | Power dissipation per pole | 5.4 W AC-1<br />2.4 W AC-3<br />2.4 W AC-3e |
[Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1<br />Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL<br />Signalling circuit 690 V IEC 60947-1 | Overvoltage category | III |
Pollution degree | 3 | [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 6 Mcycles |
Control circuit type | AC 50/60 Hz | Coil technology | Without built-in suppressor module |
Control circuit voltage limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz<br />0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz<br />1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz | Inrush power in VA | 160 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))<br />140 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)) |
Hold-in power consumption in VA | 15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))<br />13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) | Heat dissipation | 4…5 W at 50/60 Hz |
Operating time | 4...19 ms opening<br />12...26 ms closing | Maximum operating rate | 3600 cyc/h 140 °F (60 °C) |
Connections - terminals | Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw clamp terminals 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw clamp terminals 2 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw clamp terminals 2 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid | Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ø 6 to Ø 8 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2 |
Auxiliary contact composition | 1 NO + 1 NC | Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1 |
Signalling circuit frequency | 25...400 Hz | Minimum switching voltage | 17 V for signalling circuit |
Minimum switching current | 5 mA for signalling circuit | Insulation resistance | > 10 MOhm for signalling circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact | Mounting Support | Plate<br />Rail |
Standards | CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508 | Product Certifications | BV<br />CCC<br />CSA<br />DNV<br />GL<br />LROS (Lloyds register of shipping)<br />UL<br />GOST<br />RINA<br />UKCA |
Climatic withstand | IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat | Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating |
Operating altitude | 0...9842.52 ft (0...3000 m) | Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 | Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 3 Gn, 5...300 Hz) <br />Shocks contactor open 8 Gn for 11 ms) <br />Shocks contactor closed 10 Gn for 11 ms) |
Height | 5.0000000000 in (127 mm) | Width | 3.0 in (75 mm) |
Depth | 4.7 in (119 mm) | Net Weight | 3.09 lb(US) (1.4 kg) |
Specifications may be subject to change without notice