Product Model
LC1D506FW

Selling Points
- 1High-quality changeover contactor designed for reliable performance in industrial settings.
- 2110 V coil voltage ensures compatibility with a wide range of electrical systems.
- 33-pole configuration provides efficient switching and control capabilities.
- 450 A contact current rating supports heavy-duty applications with ease.
- 5Green Premium verified by Schneider Electric's Better World initiative, ensuring eco-friendly practices.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Range of Product | TeSys Deca |
Product or Component Type | Contactor | Device short name | LC1D |
Contactor application | Resistive load<br />Motor control | Utilisation category | AC-2<br />AC-4<br />AC-1<br />AC-3<br />AC-3e |
Poles description | 3P | [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz |
[Ie] rated operational current | 50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit | [Uc] control circuit voltage | 110 V DC |
Motor power kW | 22 kW at 380...400 V AC 50 Hz<br />25 kW at 415 V AC 50 Hz<br />30 kW at 440 V AC 50 Hz<br />30 kW at 500 V AC 50 Hz<br />33 kW at 660...690 V AC 50 Hz<br />15 kW at 220...230 V AC 50 Hz<br />30 kW at 1000 V AC 50 Hz | Maximum Horse Power Rating | 3 hp at 115 V AC 60 Hz for 1 phase motors<br />7.5 hp at 230/240 V AC 60 Hz for 1 phase motors<br />15 hp at 200/208 V AC 60 Hz for 3 phase motors<br />15 hp at 230/240 V AC 60 Hz for 3 phase motors<br />40 hp at 460/480 V AC 60 Hz for 3 phase motors<br />40 hp at 575/600 V AC 60 Hz for 3 phase motors |
compatibility code | LC1D | Pole contact composition | 3 NO |
Protective cover | With | [Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for control circuit<br />80 A (at 140 °F (60 °C)) for power circuit |
Irms rated making capacity | 250 A DC for control circuit conforming to IEC 60947-5-1<br />900 A at 440 V for power circuit conforming to IEC 60947 | Rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
Associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1<br />100 A gG at <= 690 V coordination type 1 for power circuit<br />100 A gG at <= 690 V coordination type 2 for power circuit | Power dissipation per pole | 3.7 W AC-3<br />9.6 W AC-1<br />3.7 W AC-3e |
[Ui] rated insulation voltage | Control circuit 600 V CSA<br />Control circuit 600 V UL<br />Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Control circuit 690 V IEC 60947-1<br />Power circuit 690 V IEC 60947-1 | Overvoltage category | III |
[Uimp] rated impulse withstand voltage | 8 kV IEC 60947 | Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 10000000 cycles | Control circuit type | DC wide range |
Coil technology | Built-in bidirectional peak limiting diode suppressor | Control circuit voltage limits | 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC<br />0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC<br />1...1.25 Uc 140…158 °F (60…70 °C) operational DC |
Inrush power in W | 19 W 68 °F (20 °C)) | Hold-in power consumption in W | 7.4 W 68 °F (20 °C) |
Operating time | 20 ms opening<br />50 ms closing | Time constant | 34 ms |
Maximum operating rate | 3600 cyc/h 140 °F (60 °C) | Connections - terminals | Control circuit: lugs - external diameter: 0.3 in (8 mm)<br />Power circuit: lugs - external diameter: 0.6 in (16 mm) |
Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) lugs Philips No 2<br />Control circuit 15.05 lbf.in (1.7 N.m) lugs flat Ø 6 mm<br />Power circuit 22.1 lbf.in (2.5 N.m) lugs flat Ø 8 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) lugs pozidriv No 2 | Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1 | Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit | Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contacts<br />1.5 ms on energisation between NC and NO contacts | Mounting Support | Rail<br />Plate |
Standards | IEC 60947-4-1<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-5-1<br />CSA C22.2 No 14<br />UL 508 | Product Certifications | GL<br />BV<br />CCC<br />LROS (Lloyds register of shipping)<br />RINA<br />UL<br />GOST<br />DNV<br />CSA<br />UKCA |
IP degree of protection | IP2X IEC 60529<br />IP2X VDE 0106 | Climatic withstand | IACS E10 exposure to damp heat |
Operating altitude | 0...9842.52 ft (0...3000 m) | Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 | Mechanical robustness | Shocks contactor opened 10 Gn for 11 ms) <br />Shocks contactor closed 15 Gn for 11 ms) <br />Vibrations contactor opened 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) |
Height | 5.0000000000 in (127 mm) | Width | 3.3 in (85 mm) |
Depth | 6.9 in (176 mm) | Net Weight | 4.817 lb(US) (2.185 kg) |
Specifications may be subject to change without notice