schneider LC1D50B7

Selling Points

  • 1High-Performance Motor Control: Designed to control and provide overload protection to motors rated up to 100 HP at 480 VAC or 125 HP at 600 VAC.
  • 2Reliable Contact Configuration: 3NO contact configuration with 50 A at 600 VAC contact rating, ensuring reliable operation in various applications.
  • 3Efficient Coil Technology: 24VAC coil with 140/160 VA inrush and 13/15 VA hold-in, reducing energy consumption and improving efficiency.
  • 4Versatile Installation Options: Easy installation with screw clamp terminals and IP2X enclosure, suitable for both North American and International applications.
  • 5Comprehensive Safety Features: Meets or exceeds SCCR requirements, ensuring high-fault short circuit current ratings for safe operation in diverse environments.
Product Details
LC1D50B7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC-1<br />AC-2<br />AC-3e<br />AC-1
Poles description
3P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
[Ie] rated operational current
50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit<br />80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
[Uc] control circuit voltage
120 V AC 50/60 Hz
Motor power kW
30 kW at 440 V AC 50 Hz (AC-3)<br />30 kW at 500 V AC 50 Hz (AC-3)<br />33 kW at 660...690 V AC 50 Hz (AC-3)<br />15 kW at 220...230 V AC 50 Hz (AC-3)<br />11 kW at 400 V AC 50 Hz (AC-4)<br />30 kW at 1000 V AC 50 Hz (AC-3)<br />22 kW at 380...400 V AC 50 Hz (AC-3e)<br />25 kW at 415 V AC 50 Hz (AC-3e)<br />30 kW at 440 V AC 50 Hz (AC-3e)<br />30 kW at 500 V AC 50 Hz (AC-3e)<br />33 kW at 660...690 V AC 50 Hz (AC-3e)<br />15 kW at 220...230 V AC 50 Hz (AC-3e)<br />30 kW at 1000 V AC 50 Hz (AC-3e)<br />30 kW at 380...400 V AC 50 Hz (AC-3)
Maximum Horse Power Rating
15 hp at 200/208 V AC 60 Hz for 3 phase motors<br />15 hp at 230/240 V AC 60 Hz for 3 phase motors<br />40 hp at 460/480 V AC 60 Hz for 3 phase motors<br />40 hp at 575/600 V AC 60 Hz for 3 phase motors<br />5 hp at 115 V AC 60 Hz for 1 phase motors<br />10 hp at 230/240 V AC 60 Hz for 1 phase motors
compatibility code
LC1D
Pole contact composition
3 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for control circuit<br />80 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
1000 A at 440 V for power circuit conforming to IEC 60947<br />140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity
1000 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
100 A gG at <= 690 V coordination type 2 for power circuit<br />10 A gG for control circuit conforming to IEC 60947-5-1<br />125 A gG at <= 690 V coordination type 1 for power circuit
Power dissipation per pole
3.7 W AC-3e<br />9.6 W AC-1<br />6.3 W AC-3
[Ui] rated insulation voltage
Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Control circuit 690 V IEC 60947-1<br />Power circuit 690 V IEC 60947-1<br />Control circuit 600 V CSA<br />Control circuit 600 V UL
Overvoltage category
III
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
6000000 cycles
Control circuit type
AC 50/60 Hz
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz<br />1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz<br />0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz
Inrush power in VA
140 VA cos phi 0.75 (at 68 °F (20 °C))<br />160 VA cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA
13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))<br />15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation
4…5 W at 50/60 Hz for control circuit
Operating time
4...19 ms opening<br />12...26 ms closing
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Connections - terminals
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) - cable stiffness: rigid<br />Power circuit: screw terminals 2 0.004…0.02 in² (2.5…16 mm²) - cable stiffness: rigid<br />Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw terminals 2 0.004…0.02 in² (2.5…16 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw terminals 1 0.004…0.04 in² (2.5…25 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid
Tightening torque
Power circuit 44.3 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1
Minimum switching voltage
17 V for control circuit
Minimum switching current
5 mA for control circuit
Insulation resistance
> 10 MOhm for control circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contacts<br />1.5 ms on energisation between NC and NO contacts
Mounting Support
Rail
Standards
EN 60947-5-1<br />UL 508<br />IEC 60947-4-1<br />IEC 60947-5-1
Product Certifications
GOST<br />GL<br />DNV<br />LROS (Lloyds register of shipping)<br />CCC<br />RINA<br />BV<br />UKCA<br />UL
IP degree of protection
IP2X IEC 60529<br />IP2X VDE 0106
Climatic withstand
IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor opened 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) <br />Shocks contactor opened 10 Gn for 11 ms)
Height
4.8 in (122 mm)
Width
2.2 in (55 mm)
Depth
4.7 in (120 mm)
Net Weight
3.09 lb(US) (1.4 kg)
Quantity per Set
Set of 10