Selling Points

  • 1High-voltage contactor for 575VAC applications.
  • 265A current rating for reliable operation.
  • 3IEC options available for customization.
  • 4Durable design for industrial use.
  • 5Compatible with various control systems.
Product Details
LC1D65004X6
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range of Product
TeSys D<br />TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
[Ue] rated operational voltage
Power circuit 690 V AC 25...400 Hz
[Ie] rated operational current
80 A (at <140 °F (60 °C)) at 440 V AC AC-1 for power circuit
[Uc] control circuit voltage
600 V AC 60 Hz
compatibility code
LC1D
Pole contact composition
4 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for control circuit<br />80 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
1000 A at 440 V AC for power circuit conforming to IEC 60947<br />140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity
1000 kA at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1<br />125 A at 690 V coordination type 1 for power circuit<br />125 A at 690 V coordination type 2 for power circuit
Average impedance
1 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole
6.3 W AC-3<br />9.6 W AC-1
[Ui] rated insulation voltage
Control circuit 600 V CSA<br />Control circuit 600 V UL<br />Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Control circuit 690 V IEC 60947-4-1<br />Power circuit 690 V IEC 60947-4-1
Overvoltage category
III
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
6000000 cycles
Control circuit type
AC 60 Hz standard
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.3...0.6 Uc 140 °F (60 °C) drop-out AC 50/60 Hz<br />0.85...1.1 Uc 140 °F (60 °C) operational AC 60 Hz
Inrush power in VA
140 VA cos phi 0.75 (at 68 °F (20 °C))
Heat dissipation
4…5 W at 50/60 Hz for control circuit
Operating time
12...26 ms closing<br />4...19 ms opening
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Connections - terminals
Control circuit: screw clamp terminal 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminal 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminal 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Power circuit: screw clamp terminal 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid without cable end<br />Power circuit: screw clamp terminal 2 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid without cable end
Tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal flat Ø 6 mm hexagonal<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal Philips No 2 hexagonal<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminal pozidriv No 2
Auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1
Minimum switching voltage
17 V for control circuit
Minimum switching current
5 mA for control circuit
Insulation resistance
> 10 MOhm for control circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contacts<br />1.5 ms on energisation between NC and NO contacts
Mounting Support
Rail<br />Plate
Standards
CSA C22.2 No 14<br />UL 508<br />EN/IEC 60947-4-1<br />EN/IEC 60947-5-1
Product Certifications
DNV<br />BV<br />CCC<br />GL<br />UL<br />RINA<br />LROS (Lloyds register of shipping)<br />CSA
IP degree of protection
IP2X VDE 0106
Protective treatment
THIEC 60068-2-30
Permissible ambient air temperature around the device
-76…176 °F (-60…80 °C) storage<br />-40…140 °F (-40…60 °C) operation<br />140…158 °F (60…70 °C) with derating
Operating altitude
9842.52 ft (3000 m) without derating
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Shocks contactor opened 15 gn) <br />Shocks contactor closed<br />Vibrations contactor opened<br />Vibrations contactor closed
Height
4.8 in (122 mm)
Width
3.3 in (85 mm)
Depth
5.1 in (130 mm)

Specifications may be subject to change without notice