schneider LC1D800086J5

Selling Points

  • 1The LC1D800086J5 contactor supports up to 12 AC, ensuring reliable power control in demanding industrial environments.
  • 2The product features a multi-color design for easy identification and integration into various electrical systems.
  • 3Built with durable materials, this contactor withstands the rigors of continuous operation in industrial settings.
  • 4Compatible with 12 V AC 50 Hz coil, offering flexibility in system design and integration.
  • 5Equipped with ring-lug terminals for secure and efficient connections, reducing the risk of electrical faults.
Product Details
LC1D800086J5
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
[Ue] rated operational voltage
Power circuit <= 300 V DC 25...400 Hz<br />Power circuit <= 690 V AC
[Ie] rated operational current
125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage
12 V AC 50 Hz
compatibility code
LC1D
Pole contact composition
2 NO + 2 NC
Protective cover
Without
[Ith] conventional free air thermal current
125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
640 A 104 °F (40 °C) - 10 s for power circuit<br />990 A 104 °F (40 °C) - 1 s for power circuit<br />135 A 104 °F (40 °C) - 10 min for power circuit<br />320 A 104 °F (40 °C) - 1 min for power circuit
Associated fuse rating
200 A gG at <= 690 V coordination type 1 for power circuit<br />160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole
12.5 W AC-1
[Ui] rated insulation voltage
Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1
Overvoltage category
III
Pollution degree
3
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
10 Mcycles
Electrical durability
0.8 Mcycles 125 A AC-1 <= 440 V
Control circuit type
AC 50 Hz
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50 Hz<br />0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz<br />1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50 Hz
Inrush power in VA
200 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA
20 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation
6…10 W at 50 Hz
Operating time
20...35 ms closing<br />6...20 ms opening
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Connections - terminals
Control circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm)<br />Power circuit: bars 1 - busbar cross section: 3 x 16 mm<br />Power circuit: lugs-ring terminals - external diameter: 0.7 in (17 mm)
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals flat Ø 6 mm M3.5<br />Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals Philips No 2 M3.5<br />Power circuit 44.3 lbf.in (5 N.m) lugs-ring terminals flat Ø 8 mm M6<br />Power circuit 44.3 lbf.in (5 N.m) lugs-ring terminals hexagonal 0.4 in (10 mm) M6<br />Power circuit 44.3 lbf.in (5 N.m) bars flat Ø 8 mm M6<br />Power circuit 44.3 lbf.in (5 N.m) bars hexagonal 0.4 in (10 mm) M6
Mounting Support
Plate<br />Rail
Standards
CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508
Product Certifications
UL<br />BV<br />CSA<br />CCC<br />RINA<br />GOST<br />DNV<br />LROS (Lloyds register of shipping)<br />GL
IP degree of protection
IP20 front face IEC 60529
Protective treatment
THIEC 60068-2-30
Climatic withstand
IACS E10 exposure to damp heat
Permissible ambient air temperature around the device
-76…176 °F (-60…80 °C) storage<br />-40…140 °F (-40…60 °C) operation<br />140…158 °F (60…70 °C) with derating
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz) <br />Shocks contactor open 8 Gn for 11 ms) <br />Vibrations contactor closed 3 Gn, 5...300 Hz) <br />Shocks contactor closed 10 Gn for 11 ms)
Height
5.0000000000 in (127 mm)
Width
3.8 in (96 mm)
Depth
5.5 in (140 mm)
Net Weight
4.06 lb(US) (1.84 kg)

Specifications may be subject to change without notice