Product Model
LC1D80008B7

Selling Points
- 1Reduces operational costs with advanced energy-saving technologies.
- 2Ensures consistent performance in demanding industrial environments.
- 3Suitable for installations where space is premium, with a robust build.
- 4Easy installation and maintenance due to user-friendly features.
- 5Meets industry standards and regulations, providing peace of mind for operators and engineers.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Range of Product | TeSys Deca |
Product or Component Type | Contactor | Device short name | LC1D |
Contactor application | Resistive load | Utilisation category | AC-1 |
Poles description | 4P | [Ue] rated operational voltage | Power circuit <= 300 V DC<br />Power circuit <= 690 V AC 25...400 Hz |
[Ie] rated operational current | 125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit | [Uc] control circuit voltage | 24 V AC 50/60 Hz |
compatibility code | LC1D | Pole contact composition | 2 NO + 2 NC |
Protective cover | Without | [Ith] conventional free air thermal current | 125 A (at 140 °F (60 °C)) for power circuit |
Irms rated making capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 | Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 640 A 104 °F (40 °C) - 10 s for power circuit<br />990 A 104 °F (40 °C) - 1 s for power circuit<br />135 A 104 °F (40 °C) - 10 min for power circuit<br />320 A 104 °F (40 °C) - 1 min for power circuit | Associated fuse rating | 200 A gG at <= 690 V coordination type 1 for power circuit<br />160 A gG at <= 690 V coordination type 2 for power circuit |
Average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | Power dissipation per pole | 12.5 W AC-1 |
[Ui] rated insulation voltage | Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1 | Overvoltage category | III |
Pollution degree | 3 | [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 4 Mcycles |
Electrical durability | 0.8 Mcycles 125 A AC-1 <= 440 V | Control circuit type | AC 50/60 Hz |
Coil technology | Without built-in suppressor module | Control circuit voltage limits | 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz<br />0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz<br />1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz |
Inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))<br />245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) | Hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))<br />26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) |
Heat dissipation | 6…10 W at 50/60 Hz | Operating time | 20...35 ms closing<br />6...20 ms opening |
Maximum operating rate | 3600 cyc/h 140 °F (60 °C) | Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: solid without cable end |
Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2<br />Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm<br />Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) | Mounting Support | Rail<br />Plate |
Standards | CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508 | Product Certifications | GL<br />RINA<br />UL<br />CSA<br />CCC<br />BV<br />DNV<br />LROS (Lloyds register of shipping)<br />GOST |
IP degree of protection | IP20 front face IEC 60529 | Protective treatment | THIEC 60068-2-30 |
Climatic withstand | IACS E10 exposure to damp heat | Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating |
Operating altitude | 0...9842.52 ft (0...3000 m) | Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 | Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) <br />Shocks contactor open 8 Gn for 11 ms) <br />Vibrations contactor closed 3 Gn, 5...300 Hz) <br />Shocks contactor closed 10 Gn for 11 ms) |
Height | 5.0000000000 in (127 mm) | Width | 3.8 in (96 mm) |
Depth | 5.5 in (140 mm) | Net Weight | 4.06 lb(US) (1.84 kg) |
Specifications may be subject to change without notice