Product Model
LC1D80008F5

Selling Points
- 1Enhance energy efficiency with innovative technologies, reducing operational costs and maximizing productivity.
- 2Compact yet sturdy build, suitable for installations where space is a premium, ensuring optimal electrical conductivity.
- 3Hassle-free installation and maintenance with user-friendly features, making it easy to integrate into electrical systems.
- 4Meets industry standards and regulations, providing peace of mind with its safe and reliable operation.
- 5Easy and safe direct mounting between the contactor and circuit breaker, thanks to EverLink terminal block, with DIN rail and surface mounting capabilities.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Range of Product | TeSys Deca |
Product or Component Type | Contactor | Device short name | LC1D |
Contactor application | Resistive load | Utilisation category | AC-1 |
Poles description | 4P | [Ue] rated operational voltage | Power circuit <= 300 V DC<br />Power circuit <= 690 V AC 25...400 Hz |
[Ie] rated operational current | 125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit | [Uc] control circuit voltage | 110 V AC 50 Hz |
compatibility code | LC1D | Pole contact composition | 2 NO + 2 NC |
Protective cover | Without | [Ith] conventional free air thermal current | 125 A (at 140 °F (60 °C)) for power circuit |
Irms rated making capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 | Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 640 A 104 °F (40 °C) - 10 s for power circuit<br />990 A 104 °F (40 °C) - 1 s for power circuit<br />135 A 104 °F (40 °C) - 10 min for power circuit<br />320 A 104 °F (40 °C) - 1 min for power circuit | Associated fuse rating | 200 A gG at <= 690 V coordination type 1 for power circuit<br />160 A gG at <= 690 V coordination type 2 for power circuit |
Average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | Power dissipation per pole | 12.5 W AC-1 |
[Ui] rated insulation voltage | Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1 | Overvoltage category | III |
Pollution degree | 3 | [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 10 Mcycles |
Electrical durability | 0.8 Mcycles 125 A AC-1 <= 440 V | Control circuit type | AC 50 Hz |
Coil technology | Without built-in suppressor module | Control circuit voltage limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50 Hz<br />0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz<br />1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50 Hz |
Inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) | Hold-in power consumption in VA | 20 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) |
Heat dissipation | 6…10 W at 50 Hz | Operating time | 20...35 ms closing<br />6...20 ms opening |
Maximum operating rate | 3600 cyc/h 140 °F (60 °C) | Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: solid without cable end |
Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2<br />Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm<br />Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) | Mounting Support | Plate<br />Rail |
Standards | CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508 | Product Certifications | DNV<br />RINA<br />LROS (Lloyds register of shipping)<br />GL<br />CCC<br />UL<br />BV<br />GOST<br />CSA |
IP degree of protection | IP20 front face IEC 60529 | Protective treatment | THIEC 60068-2-30 |
Climatic withstand | IACS E10 exposure to damp heat | Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating |
Operating altitude | 0...9842.52 ft (0...3000 m) | Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 | Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) <br />Shocks contactor open 8 Gn for 11 ms) <br />Vibrations contactor closed 3 Gn, 5...300 Hz) <br />Shocks contactor closed 10 Gn for 11 ms) |
Height | 5.0000000000 in (127 mm) | Width | 3.8 in (96 mm) |
Depth | 5.5 in (140 mm) | Net Weight | 4.06 lb(US) (1.84 kg) |
Specifications may be subject to change without notice