schneider LC1D806FE7

Selling Points

  • 1High Performance: Rated for currents of 125A (AC-1) and 80A (440Vac; AC-3).
  • 2Durable Design: Mechanical durability of 15 million operations at no load and 1.6 million operations with load.
  • 3Versatile Mounting: Suitable for DIN rail mounting with a net width of 85 mm.
  • 4Reliable Operation: Operates within a control voltage range of 92-126Vac (115Vac nominal; 50Hz) and 98-126Vac (115Vac nominal; 60Hz).
  • 5Wide Application Range: Handles rated active power from 2HP at 115Vac to 20HP at 575-600Vac under UL/CSA standards.
Product Details
LC1D806FE7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys Deca
Product or Component Type
Contactor
Device short name
LC1D
Contactor application
Resistive load<br />Motor control
Utilisation category
AC-3<br />AC-3e<br />AC-4<br />AC-1
Poles description
3P
[Ue] rated operational voltage
Power circuit <= 300 V DC 25...400 Hz<br />Power circuit <= 690 V AC
[Ie] rated operational current
125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
115 V AC 50/60 Hz
Motor power kW
22 kW at 220...230 V AC 50/60 Hz (AC-3)<br />37 kW at 380...400 V AC 50/60 Hz (AC-3)<br />45 kW at 415...440 V AC 50/60 Hz (AC-3)<br />55 kW at 500 V AC 50/60 Hz (AC-3)<br />45 kW at 660...690 V AC 50/60 Hz (AC-3)<br />15 kW at 400 V AC 50/60 Hz (AC-4)<br />22 kW at 220...230 V AC 50/60 Hz (AC-3e)<br />37 kW at 380...400 V AC 50/60 Hz (AC-3e)<br />45 kW at 415...440 V AC 50/60 Hz (AC-3e)<br />55 kW at 500 V AC 50/60 Hz (AC-3e)<br />45 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating
7.5 hp at 120 V AC 50/60 Hz for 1 phase motors<br />15 hp at 230/240 V AC 50/60 Hz for 1 phase motors<br />30 hp at 200/208 V AC 50/60 Hz for 3 phase motors<br />30 hp at 230/240 V AC 50/60 Hz for 3 phase motors<br />60 hp at 460/480 V AC 50/60 Hz for 3 phase motors<br />60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
compatibility code
LC1D
Pole contact composition
3 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for signalling circuit<br />125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1<br />1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
640 A 104 °F (40 °C) - 10 s for power circuit<br />990 A 104 °F (40 °C) - 1 s for power circuit<br />135 A 104 °F (40 °C) - 10 min for power circuit<br />320 A 104 °F (40 °C) - 1 min for power circuit<br />100 A - 1 s for signalling circuit<br />120 A - 500 ms for signalling circuit<br />140 A - 100 ms for signalling circuit
Associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1<br />200 A gG at <= 690 V coordination type 1 for power circuit<br />160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole
5.1 W AC-3<br />12.5 W AC-1
[Ui] rated insulation voltage
Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-1<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL
Overvoltage category
III
Pollution degree
3
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
4 Mcycles
Electrical durability
0.8 Mcycles 125 A AC-1 <= 440 V<br />1.5 Mcycles 80 A AC-3 <= 440 V
Control circuit type
AC 50/60 Hz
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz<br />0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz<br />1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
Inrush power in VA
245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))<br />245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA
26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))<br />26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation
6…10 W at 50/60 Hz
Operating time
20...35 ms closing<br />6...20 ms opening
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Connections - terminals
Control circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm)<br />Power circuit: bars 1 - busbar cross section: 3 x 16 mm<br />Power circuit: lugs-ring terminals - external diameter: 0.7 in (17 mm)
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals flat Ø 6 mm M3.5<br />Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals Philips No 2 M3.5<br />Power circuit 44.3 lbf.in (5 N.m) lugs-ring terminals flat Ø 8 mm M6<br />Power circuit 44.3 lbf.in (5 N.m) lugs-ring terminals hexagonal 0.4 in (10 mm) M6<br />Power circuit 44.3 lbf.in (5 N.m) bars flat Ø 8 mm M6<br />Power circuit 44.3 lbf.in (5 N.m) bars hexagonal 0.4 in (10 mm) M6
Auxiliary contact composition
1 NO + 1 NC
Auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency
25...400 Hz
Minimum switching voltage
17 V for signalling circuit
Minimum switching current
5 mA for signalling circuit
Insulation resistance
> 10 MOhm for signalling circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact
Mounting Support
Plate<br />Rail
Standards
CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508
Product Certifications
DNV<br />RINA<br />GOST<br />UL<br />BV<br />GL<br />CSA<br />CCC<br />LROS (Lloyds register of shipping)
IP degree of protection
IP20 front face IEC 60529
Protective treatment
THIEC 60068-2-30
Climatic withstand
IACS E10 exposure to damp heat
Permissible ambient air temperature around the device
-40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating
Operating altitude
0...9842.52 ft (0...3000 m)
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open 2 Gn, 5...300 Hz) <br />Shocks contactor open 8 Gn for 11 ms) <br />Vibrations contactor closed 3 Gn, 5...300 Hz) <br />Shocks contactor closed 10 Gn for 11 ms)
Height
5.0000000000 in (127 mm)
Width
3.3 in (85 mm)
Depth
5.1 in (130 mm)
Net Weight
3.51 lb(US) (1.59 kg)

Specifications may be subject to change without notice