Product Model
LC1D95X6

Selling Points
- 1High-Reliability Design: Built to handle heavy systems with a 3-pole, 95 AMP AC-3 rating.
- 2Versatile Control: Compatible with both 230V and 460V 3-phase systems, supporting up to 60 HP.
- 3Enhanced Safety Features: Includes 1 NO and 1 NC base-mounted contactor with optional LADN auxiliary contacts.
- 4Easy Installation: Features screw clamp terminals and can be panel or DIN rail mounted.
- 5Comprehensive Protection: Ideal for inductive motor applications, providing overload protection up to 100 HP at 480 Vac or 125 HP at 600 Vac.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Range of Product | TeSys Deca |
Product or Component Type | Contactor | Device short name | LC1D |
Contactor application | Motor control<br />Resistive load | Utilisation category | AC-3<br />AC-3e<br />AC-4<br />AC-1 |
Poles description | 3P | [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz |
[Ie] rated operational current | 95 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit<br />125 A (at <140 °F (60 °C)) at <= 1000 V AC-1 for power circuit | [Uc] control circuit voltage | 600 V AC 60 Hz |
Motor power kW | 25 kW at 220...230 V AC 50 Hz (AC-3)<br />45 kW at 380...400 V AC 50 Hz (AC-3)<br />45 kW at 415...440 V AC 50 Hz (AC-3)<br />55 kW at 500 V AC 50 Hz (AC-3)<br />45 kW at 660...690 V AC 50 Hz (AC-3)<br />15 kW at 400 V AC 50 Hz (AC-4)<br />25 kW at 220...230 V AC 50 Hz (AC-3e)<br />45 kW at 380...400 V AC 50 Hz (AC-3e)<br />45 kW at 415...440 V AC 50 Hz (AC-3e)<br />55 kW at 500 V AC 50 Hz (AC-3e)<br />45 kW at 660...690 V AC 50 Hz (AC-3e) | Maximum Horse Power Rating | 7.5 hp at 115 V AC 60 Hz for 1 phase motors<br />15 hp at 230/240 V AC 60 Hz for 1 phase motors<br />25 hp at 200/208 V AC 60 Hz for 3 phase motors<br />30 hp at 230/240 V AC 60 Hz for 3 phase motors<br />60 hp at 460/480 V AC 60 Hz for 3 phase motors<br />60 hp at 575/600 V AC 60 Hz for 3 phase motors |
compatibility code | LC1D | Pole contact composition | 3 NO |
Protective cover | With | [Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for signalling circuit<br />125 A (at 140 °F (60 °C)) for power circuit |
Irms rated making capacity | 1100 A at 440 V AC for power circuit conforming to IEC 60947<br />140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1 | Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 1100 A 104 °F (40 °C) - 1 s for power circuit<br />800 A 104 °F (40 °C) - 10 s for power circuit<br />400 A 104 °F (40 °C) - 1 min for power circuit<br />135 A 104 °F (40 °C) - 10 min for power circuit<br />140 A - 100 ms for signalling circuit<br />120 A - 500 ms for signalling circuit<br />100 A - 1 s for signalling circuit | Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1<br />160 A gG at <= 690 V coordination type 2 for power circuit<br />200 A gG at <= 690 V coordination type 1 for power circuit |
Average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | Power dissipation per pole | 12.5 W AC-1<br />7.2 W AC-3 |
[Ui] rated insulation voltage | Power circuit 1000 V IEC 60947-4-1<br />Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Signalling circuit 690 V IEC 60947-1<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL | Overvoltage category | III |
[Uimp] rated impulse withstand voltage | 8 kV IEC 60947 | Safety reliability level | B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical durability | 10 Mcycles | Electrical durability | 1.2 Mcycles 95 A AC-3<br />1.3 Mcycles 125 A AC-1 |
Control circuit type | AC 60 Hz | Coil technology | Without built-in suppressor module |
Control circuit voltage limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 60 Hz<br />0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz<br />1...1.1 Uc 131…158 °F (55…70 °C) operational AC 60 Hz | Inrush power in VA | 220 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C)) |
Hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) | Heat dissipation | 6…10 W at 60 Hz for control circuit |
Operating time | 20...35 ms closing<br />6...20 ms opening | Maximum operating rate | 3600 cyc/h at 60 °C |
Connections - terminals | Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw terminals 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: rigid<br />Power circuit: screw terminals 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: rigid<br />Power circuit: screw terminals 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw terminals 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw terminals 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw terminals 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end | Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal flat Ø 6 mm<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal Philips No 2<br />Power circuit 106.2 lbf.in (12 N.m) screw terminal flat Ø 6 to Ø 8 mm<br />Power circuit 106.2 lbf.in (12 N.m) screw terminal hex (Allen key) 0.2 in (4 mm)<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminal pozidriv No 2 |
Auxiliary contact composition | 1 NO + 1 NC | Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1 |
Minimum switching voltage | 17 V for signalling circuit | Minimum switching current | 5 mA for signalling circuit |
Insulation resistance | > 10 MOhm for signalling circuit | Non-overlap time | 1.5 ms on de-energisation between NC and NO contacts<br />1.5 ms on energisation between NC and NO contacts |
Mounting Support | Rail<br />Plate | Standards | EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />CSA C22.2 No 14<br />UL 60947-4-1<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ<br />IEC 60335-1:Clause 30.2 |
Product Certifications | CCC<br />UL<br />CB Scheme<br />CSA<br />CE<br />UKCA<br />Marine<br />EAC | IP degree of protection | IP20 IEC 60529 |
Protective treatment | TH 3)IEC 60068-2-30 | Climatic withstand | IACS E10 exposure to damp heat |
Operating altitude | 0...9842.52 ft (0...3000 m) | Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 | Mechanical robustness | Shocks contactor opened 8 Gn for 11 ms) <br />Shocks contactor closed 10 Gn for 11 ms) <br />Vibrations contactor opened 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 3 Gn, 5...300 Hz) |
Height | 5.0000000000 in (127 mm) | Width | 3.3 in (85 mm) |
Depth | 5.1 in (130 mm) | Net Weight | 3.55 lb(US) (1.61 kg) |
Specifications may be subject to change without notice