schneider LC1DPKQ7

Selling Points

  • 130 kVAR at 400 V/50 Hz for efficient power factor correction.
  • 2Compatible with 380 V AC 50/60 Hz coils for flexible installation.
  • 3Includes 1 NO + 2 NC instantaneous auxiliary contacts for precise control.
  • 4Built to withstand 300,000 cycles at Ue 400 V, ensuring long-lasting performance.
  • 5Easy installation with multi-standard screws for a secure connection.
Product Details
LC1DPKQ7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Product name
TeSys LC1D.K<br />TeSys Deca
Product or Component Type
Capacitor duty contactor
Device short name
LC1DPK
Device Application
Control
Contactor application
Power factor correction
Utilisation category
AC-6b
Poles description
3P
power pole contact composition
3 NO
Device location in system
Line interruption<br />Inside delta interruption
[Ue] rated operational voltage
Power circuit 690 V AC 50/60 Hz
Reactive power rating
17 kvar 230 V AC 50 Hz 140 °F (60 °C)<br />30 kvar 400 V AC 50 Hz 140 °F (60 °C)<br />32 kvar 440 V AC 50 Hz 140 °F (60 °C)<br />50 kvar 690 V AC 50 Hz 140 °F (60 °C)<br />16.5 kvar 230 V AC 60 Hz 140 °F (60 °C)<br />33.3 kvar 460 V AC 60 Hz 140 °F (60 °C)<br />40 kvar 575 V AC 60 Hz 140 °F (60 °C)
Control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
380 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 2 NC instantaneous
Electrical durability
300000 cycles 400 V<br />200000 cycles 690 V
Mounting Support
DIN rail<br />Plate
Standards
EN/IEC 60947-1<br />EN/IEC 60947-4-1<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1
Product Certifications
IECEE CB Scheme<br />UL<br />CSA
Connections - terminals
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Power circuit: EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid<br />Power circuit: EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: solid<br />Power circuit: EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible with or without cable end<br />Power circuit: EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible with or without cable end
Tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals<br />Power circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors 0.002…0.04 in² (1…25 mm²)<br />Power circuit 70.8 lbf.in (8 N.m) EverLink BTR screw connectors 0.05 in² (35 mm²)
Maximum operating rate
240 cyc/h
Auxiliary contacts type
Mechanically linked 1 NO + 2 NC IEC 60947-5-1
IP degree of protection
IP20 front face IEC 60529
Ambient Air Temperature for Operation
23…140 °F (-5…60 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Operating altitude
0...9842.52 ft (0...3000 m)
Height
6.5 in (166 mm)
Width
2.2 in (55 mm)
Depth
6.1 in (156 mm)
Net Weight
2.9 lb(US) (1.3 kg)

Specifications may be subject to change without notice