schneider LC1F1154

Selling Points

  • 1Controls motors up to 1000 A (500 kW / 440 V).
  • 2Green Premium compliant for environmental performance.
  • 3Robust design with high mechanical robustness.
  • 4Rated for resistive loads with 4P(4 NO) configuration.
  • 5Compliant with IEC 60947-4-1 standards for safety and reliability.
Product Details
LC1F1154
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Product name
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
power pole contact composition
4 NO
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz<br /> <= 460 V DC
[Ie] rated operational current
200 A 104 °F (40 °C)) <= 440 V AC-1
[Uc] control circuit voltage
24...575 V AC 40...400 Hz with LX9 coil<br />24...460 V DC with LX4 coil<br />100...250 V AC 50/60 Hz with LXE coil<br />100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
200 A (at 104 °F (40 °C))
Irms rated making capacity
1150 A conforming to IEC 60947-4-1
Rated breaking capacity
920 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
1100 A 104 °F (40 °C) - 10 s<br />640 A 104 °F (40 °C) - 30 s<br />520 A 104 °F (40 °C) - 1 min<br />400 A 104 °F (40 °C) - 3 min<br />320 A 104 °F (40 °C) - 10 min
Associated fuse rating
200 A gG at <= 440 V
Average impedance
0.37 mOhm - Ith 200 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
15 W AC-1
Control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil<br />Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil<br />Operational: 0.85...1.1 Uc DC with LX4 coil<br />Drop-out: 0.15...0.2 Uc DC with LX4 coil<br />Operational: 85...275 V AC 50/60 Hz with LXE coil<br />Drop-out: 0...60 V AC 50/60 Hz with LXE coil<br />Operational: 85...418 V DC with LXE coil<br />Drop-out: 0...45 V DC with LXE coil
Heat dissipation
5.9…7.2 W<br />2.2…5.5 W
Operating time
130 ms opening with LX9 coil<br />30...40 ms closing with LX4 coil<br />30...50 ms opening with LX4 coil<br />40...80 ms closing with LXE coil<br />6...54 ms opening with LXE coil
Mounting Support
Plate
Standards
EN 60947-4-1<br />IEC 60947-4-1<br />JIS C8201-4-1<br />EN 60947-1<br />IEC 60947-1
Product Certifications
CB<br />UL<br />RINA<br />DNV<br />LROS (Lloyds register of shipping)<br />RMRoS<br />CSA<br />ABS<br />BV<br />UKCA
Connections - terminals
Power circuit lugs-ring terminals 1 0.1 in² (95 mm²)<br />Power circuit connector 1 0.1 in² (95 mm²)<br />Power circuit bar 2 20 x 3 mm<br />Power circuit bolted connection<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)<br />Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1.0 0.0004…0.004 in² (0.25…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)solid without cable end
Tightening torque
Power circuit 88.5 lbf.in (10 N.m)<br />Control circuit 10.6 lbf.in (1.2 N.m)<br />Control circuit 5.3 lbf.in (0.6 N.m)
Inrush power in VA
590…855 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil<br />543…665 VA (at 68 °F (20 °C))with LX4 coil<br />280…310 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil<br />270…320 VA (at 68 °F (20 °C))with LXE coil
Hold-in power consumption in VA
6.6…8.1 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil<br />3.94…4.83 VA (at 68 °F (20 °C))with LX4 coil<br />4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil<br />2.5…4.0 VA (at 68 °F (20 °C))with LXE coil
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
compatibility code
LC1F
IP degree of protection
IP2X front face with shrouds IEC 60529<br />IP2X front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
-40…140 °F (-40…60 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
140…158 °F (60…70 °C) at Uc
Operating altitude
9842.52 ft (3000 m) without derating
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz<br />Vibrations contactor closed6 Gn, 5...300 Hz<br />Shocks contactor open9 Gn for 1/2 sine wave (11 ms)<br />Shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Height
6.4 in (162 mm)
Width
7.9 in (200.5 mm)
Depth
6.7 in (171 mm)
Net Weight
8.44 lb(US) (3.83 kg)