schneider LC1F1250

Selling Points

  • 1High durability: 600 cycles/hour for operating rate
  • 2High reliability: environments tolerance up to 55°C
  • 3Versatile electrical connections: AC-1 <=440V 1260A with coil LX1/LX9, 110…600V AC 40/400Hz, LX4, 48…250V DC
  • 4Non-reversing contactor design for non-inductive load applications
  • 5Made with recycled cardboard packaging for eco-friendly practices
Product Details
LC1F1250
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Product name
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz
[Ie] rated operational current
1260 A 104 °F (40 °C)) <= 440 V AC-1
[Uc] control circuit voltage
110...600 V AC 40...400 Hz with LX1/LX9 coil<br />28...250 V DC with LX4 coil
[Uimp] rated impulse withstand voltage
8 kV
Overvoltage category
III
[Ith] conventional free air thermal current
1260 A (at 104 °F (40 °C))
Irms rated making capacity
1890 A conforming to IEC 60947-4-1
Rated breaking capacity
1890 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3000 A 104 °F (40 °C) - 3 min<br />5200 A 104 °F (40 °C) - 30 s<br />4000 A 104 °F (40 °C) - 1 min<br />2000 A 104 °F (40 °C) - 10 min<br />8000 A 104 °F (40 °C) - 10 s
Associated fuse rating
1400 A gG at <= 440 V for power circuit
Average impedance
0.12 mOhm - Ith 1260 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
120 W AC-1
Control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil<br />Drop-out: 0.25...0.5 Uc AC 40...400 Hz with LX1/LX9 coil<br />Operational: 0.85...1.1 Uc DC with LX4 coil<br />Drop-out: 0.2...0.35 Uc DC with LX4 coil
Heat dissipation
20 W
Operating time
40...80 ms closing with LX1/LX9 coil<br />100...200 ms opening with LX1/LX9 coil<br />60...70 ms closing with LX4 coil<br />40...50 ms opening with LX4 coil
Mounting Support
Plate
Standards
IEC 60947-1<br />EN 60947-1<br />JIS C8201-4-1<br />EN 60947-4-1<br />IEC 60947-4-1
Product Certifications
CB<br />UL<br />CSA<br />CQC<br />CE<br />UKCA<br />CCC
Connections - terminals
Power circuit bar 2<br />Power circuit bolted connection<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)
Tightening torque
Power circuit 513.3 lbf.in (58 N.m)<br />Control circuit 10.6 lbf.in (1.2 N.m)
Mechanical durability
1 Mcycles
Inrush power in VA
1500…1730 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil<br />1420…1920 VA (at 68 °F (20 °C))with LX4 coil
Hold-in power consumption in VA
20…25 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil<br />6.5…12.5 VA (at 68 °F (20 °C))with LX4 coil
Maximum operating rate
1200 cyc/h 131 °F (55 °C)
Protective treatment
TH
Ambient Air Temperature for Operation
23…104 °F (-5…40 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…140 °F (-40…60 °C)
Operating altitude
9842.52 ft (3000 m) without derating
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz<br />Vibrations contactor closed4 Gn, 5...300 Hz<br />Shocks contactor open6 Gn for 1/2 sine wave (11 ms)<br />Shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Height
13.3 in (338 mm)
Width
12.2 in (309 mm)
Depth
10.04 in (255 mm)
Net Weight
41.9 lb(US) (19 kg)

Specifications may be subject to change without notice