schneider LC1F1400P7

Selling Points

  • 1High current rating: 1400A at 1000V for robust motor control.
  • 2Versatile frequency: Operates at 50/60Hz for universal compatibility.
  • 3Reliable design: Built with high-reliability components for long-lasting performance.
  • 4Easy installation: Screw clamp terminals and bolted connections simplify setup.
  • 5Compliant with international standards: Meets IEC, UL, CSA, and CCC certifications for global use.
Product Details
LC1F1400P7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /><= 460 V DC
[Uc] control circuit voltage
230 V AC 40...400 Hz
[Ie] rated operational current
1400 A (at <104 °F (40 °C)) AC AC-1
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
1400 A (at 104 °F (40 °C))
Rated breaking capacity
2100 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
8000 A 104 °F (40 °C) - 10 s<br />6000 A 104 °F (40 °C) - 30 s<br />4500 A 104 °F (40 °C) - 1 min<br />4000 A 104 °F (40 °C) - 3 min<br />2600 A 104 °F (40 °C) - 10 min
Associated fuse rating
1600 A gG at <= 440 V
Average impedance
0.1 mOhm - Ith 1700 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C<br /> 1000 V UL 60947-4-1
Power dissipation per pole
150 W AC-1
Overvoltage category
III
power pole contact composition
3 NO
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))<br />Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
Inrush power in VA
2200 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA
36 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
600 cyc/h 131 °F (55 °C)
Operating time
100...170 ms opening<br />40...75 ms closing
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 100 x 5 mm<br />Power circuit bolted connection
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 513.3 lbf.in (58 N.m)
Mounting Support
Plate
Heat dissipation
36 W
Standards
IEC 60947-1<br />IEC 60947-4-1<br />JIS C8201-4-1<br />EN 60947-1<br />EN 60947-4-1<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1
Product Certifications
UL<br />CSA<br />CCC<br />CB Scheme<br />EAC<br />UKCA
compatibility code
LC1F
Control circuit type
AC 40...400 Hz
Protective treatment
TH
Ambient Air Temperature for Operation
23…104 °F (-5…40 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…140 °F (-40…60 °C)
Height
13.07 in (332 mm)
Width
17.2 in (438 mm)
Depth
9.4 in (238.6 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
63.9 lb(US) (29 kg)

Specifications may be subject to change without notice