schneider LC1F150Q7

Selling Points

  • 1High current rating up to 250 A at <= 40 °C.
  • 2Suitable for motor control and resistive loads.
  • 3Compliant with IEC 60947-4-1 standards.
  • 4Green Premium label for best-in-class environmental performance.
  • 5Reliable operation with a 10 Mcycle mechanical durability.
Product Details
LC1F150Q7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Motor control<br />Resistive load
Utilisation category
AC-1<br />AC-4<br />AC-3
Poles description
3P
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz<br /><= 460 V DC
[Uc] control circuit voltage
380 V AC 40...400 Hz
[Ie] rated operational current
250 A (at <104 °F (40 °C)) at <= 440 V AC-1<br />150 A (at <131 °F (55 °C)) at <= 440 V AC-3
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
250 A (at 104 °F (40 °C))
Rated breaking capacity
1200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
1200 A 104 °F (40 °C) - 10 s<br />700 A 104 °F (40 °C) - 30 s<br />600 A 104 °F (40 °C) - 1 min<br />450 A 104 °F (40 °C) - 3 min<br />350 A 104 °F (40 °C) - 10 min
Associated fuse rating
160 A aM at <= 440 V<br />250 A gG at <= 440 V
Average impedance
0.35 mOhm - Ith 250 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
22 W AC-1<br />8 W AC-3
Overvoltage category
III
power pole contact composition
3 NO
Motor power kW
75 kW at 380...400 V AC 50/60 Hz (AC-3)<br />80 kW at 415 V AC 50/60 Hz (AC-3)<br />80 kW at 440 V AC 50/60 Hz (AC-3)<br />90 kW at 500 V AC 50/60 Hz (AC-3)<br />100 kW at 660...690 V AC 50/60 Hz (AC-3)<br />40 kW at 220...230 V AC 50/60 Hz (AC-3)<br />22 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))<br />Drop-out 0.2...0.55 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability
10 Mcycles
Inrush power in VA
770 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA
8.1 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Operating time
35 ms closing at Uc) <br />130 ms opening at Uc)
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 25 x 3 mm<br />Power circuit lugs-ring terminals 1 0.2 in² (120 mm²)<br />Power circuit connector 1 0.2 in² (120 mm²)<br />Power circuit bolted connection
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 159.3 lbf.in (18 N.m)
Mounting Support
Plate
Heat dissipation
5.9…7.2 W
Standards
IEC 60947-4-1<br />JIS C8201-4-1<br />EN 60947-4-1<br />EN 60947-1<br />IEC 60947-1
Product Certifications
DNV<br />CCC<br />ABS<br />BV<br />RINA<br />LROS (Lloyds register of shipping)<br />RMRoS<br />UL<br />CB<br />UKCA
Compatibility code
LC1F
Control circuit type
AC 40...400 Hz
IP degree of protection
IP2X front face with shrouds IEC 60529<br />IP2X front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
-40…140 °F (-40…60 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
140…158 °F (60…70 °C) at Uc
Height
6.7 in (170 mm)
Width
6.4 in (163.5 mm)
Depth
6.7 in (171 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
7.56 lb(US) (3.43 kg)

Specifications may be subject to change without notice