Product Model
LC1F265

Selling Points
- 1High reliability with long mechanical and electrical life.
- 2Suitable for resistive loads up to 1000 Amps and inductive motor applications up to 800 full load Amps.
- 3Rated for motors up to 800 horsepower at 480 Vac or 900 horsepower at 600 Vac.
- 4Offers motor control and overload protection for various industrial applications.
- 5Compatible with a variety of coil voltages (24v, 120v, 220v) for versatile use.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Product name | TeSys F |
Product or Component Type | Contactor | Device short name | LC1F |
Contactor application | Resistive load<br />Motor control | Utilisation category | AC-3<br />AC-4<br />AC-1 |
Poles description | 3P | power pole contact composition | 3 NO |
[Ie] rated operational current | 350 A 104 °F (40 °C)) <= 440 V AC AC-1<br />265 A 131 °F (55 °C)) <= 440 V AC AC-3 | Motor power kW | 132 kW at 380...400 V AC 50/60 Hz (AC-3)<br />140 kW at 415 V AC 50/60 Hz (AC-3)<br />140 kW at 440 V AC 50/60 Hz (AC-3)<br />147 kW at 1000 V AC 50/60 Hz (AC-3)<br />160 kW at 500 V AC 50/60 Hz (AC-3)<br />75 kW at 220...240 V AC 50/60 Hz (AC-3)<br />160 kW at 660...690 V AC 50/60 Hz (AC-3)<br />51 kW at 400 V AC 50/60 Hz (AC-4) |
[Uc] control circuit voltage | 24...1000 V AC 40...400 Hz with LX1/LX9 coil<br />24...460 V DC with LX4 coil<br />100...250 V AC 50/60 Hz with LXE coil<br />100...380 V with LXE coil | [Uimp] rated impulse withstand voltage | 8 kV |
Overvoltage category | III | [Ith] conventional free air thermal current | 350 A (at 104 °F (40 °C)) |
Irms rated making capacity | 2650 A AC conforming to IEC 60947-4-1 | Rated breaking capacity | 2120 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 2200 A 104 °F (40 °C) - 10 s<br />1230 A 104 °F (40 °C) - 30 s<br />950 A 104 °F (40 °C) - 1 min<br />620 A 104 °F (40 °C) - 3 min<br />480 A 104 °F (40 °C) - 10 min | Associated fuse rating | 315 A aM at <= 440 V<br />400 A gG at <= 440 V |
Average impedance | 0.3 mOhm - Ith 350 A 50 Hz | [Ui] rated insulation voltage | 1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C |
Power dissipation per pole | 37 W AC-1<br />21 W AC-3 | Control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil<br />Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil<br />Operational: 0.85...1.1 Uc DC with LX4 coil<br />Drop-out: 0.15...0.2 Uc DC with LX4 coil<br />Operational: 85...275 V AC 50/60 Hz with LXE coil<br />Drop-out: 0...60 V AC 50/60 Hz with LXE coil<br />Operational: 85...418 V DC with LXE coil<br />Drop-out: 0...45 V DC with LXE coil |
Heat dissipation | 8 W<br />2.2…2.5 W | Operating time | 40...65 ms closing with LX1/LX9 coil<br />100...170 ms opening with LX1/LX9 coil<br />40...50 ms closing with LX4 coil<br />40...65 ms opening with LX4 coil<br />40...80 ms closing with LXE coil<br />6...54 ms opening with LXE coil |
Mounting Support | Plate | Standards | IEC 60947-1<br />IEC 60947-4-1<br />JIS C8201-4-1<br />EN 60947-1<br />EN 60947-4-1 |
Product Certifications | ABS<br />CB<br />DNV<br />RMRoS<br />UL<br />CSA<br />RINA<br />LROS (Lloyds register of shipping)<br />BV<br />UKCA | Connections - terminals | Power circuit bar 2 32 x 4 mm<br />Power circuit lugs-ring terminals 1 0.4 in² (240 mm²)<br />Power circuit connector 1 0.4 in² (240 mm²)<br />Power circuit bolted connection<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)<br />Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1.0 0.0004…0.004 in² (0.25…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)solid without cable end |
Tightening torque | Power circuit 309.8 lbf.in (35 N.m)<br />Control circuit 10.6 lbf.in (1.2 N.m)<br />Control circuit 5.3 lbf.in (0.6 N.m) | Mechanical durability | 10 Mcycles |
Inrush power in VA | 600…700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil<br />655…803 VA (at 68 °F (20 °C))with LX4 coil<br />300…350 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil<br />300…310 VA (at 68 °F (20 °C))with LXE coil | Hold-in power consumption in VA | 8…10 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil<br />3.68…4.53 VA (at 68 °F (20 °C))with LX4 coil<br />4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil<br />2.5…4.0 VA (at 68 °F (20 °C))with LXE coil |
Maximum operating rate | 2400 cyc/h 131 °F (55 °C) | Compatibility code | LC1F |
[Ue] rated operational voltage | <= 1000 V AC-1<br /><= 690 V AC-3<br /><= 690 V AC-4<br /><= 460 V DC | IP degree of protection | IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106 |
Protective treatment | TH | Ambient Air Temperature for Operation | 23…131 °F (-5…55 °C) |
Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) | Permissible ambient air temperature around the device | -40…158 °F (-40…70 °C) |
Operating altitude | 9842.52 ft (3000 m) without derating | Mechanical robustness | Vibrations contactor open2 Gn, 5...300 Hz<br />Vibrations contactor closed5 Gn, 5...300 Hz<br />Shocks contactor open6 Gn for 1/2 sine wave (11 ms)<br />Shocks contactor closed15 Gn for 1/2 sine wave (11 ms) |
Height | 8.0 in (203 mm) | Width | 7.9 in (201.5 mm) |
Depth | 8.4 in (213 mm) | Net Weight | 18.83 lb(US) (8.54 kg) |
Specifications may be subject to change without notice