Product Model
LC1F2654

Selling Points
- 1High-Performance Control: Control motors up to 1000 A (500 kW / 440 V) with precision.
- 2Robust Design: Meets EN/IEC standards and has an IP20 protection rating for durability.
- 3Versatile Coil Options: Compatible with LX1/LX9, LX4, and LXE coils for various voltage requirements.
- 4Green Premium Compliance: Compliant with RoHS/REACh regulations, ensuring environmental sustainability.
- 5High Operating Rate: Supports up to 2400 cycles per hour in environments up to 55°C.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Range | TeSys | Product name | TeSys F |
Product or Component Type | Contactor | Device short name | LC1F |
Contactor application | Resistive load | Utilisation category | AC-1 |
Poles description | 4P | power pole contact composition | 4 NO |
[Ie] rated operational current | 350 A 104 °F (40 °C)) <= 440 V AC AC-1 | [Uc] control circuit voltage | 24...1000 V AC 40...400 Hz with LX1/LX9 coil<br />24...460 V DC with LX4 coil<br />100...250 V AC 50/60 Hz with LXE coil<br />100...380 V with LXE coil |
[Uimp] rated impulse withstand voltage | 8 kV | Overvoltage category | III |
[Ith] conventional free air thermal current | 350 A (at 104 °F (40 °C)) | Irms rated making capacity | 2650 A AC conforming to IEC 60947-4-1 |
Rated breaking capacity | 2120 A conforming to IEC 60947-4-1 | [Icw] rated short-time withstand current | 2200 A 104 °F (40 °C) - 10 s<br />1230 A 104 °F (40 °C) - 30 s<br />950 A 104 °F (40 °C) - 1 min<br />620 A 104 °F (40 °C) - 3 min<br />480 A 104 °F (40 °C) - 10 min |
Associated fuse rating | 315 A aM at <= 440 V<br />400 A gG at <= 440 V | Average impedance | 0.3 mOhm - Ith 350 A 50 Hz |
[Ui] rated insulation voltage | 1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C | Power dissipation per pole | 37 W AC-1 |
Control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil<br />Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil<br />Operational: 0.85...1.1 Uc DC with LX4 coil<br />Drop-out: 0.15...0.2 Uc DC with LX4 coil<br />Operational: 85...275 V AC 50/60 Hz with LXE coil<br />Drop-out: 0...60 V AC 50/60 Hz with LXE coil<br />Operational: 85...418 V DC with LXE coil<br />Drop-out: 0...45 V DC with LXE coil | Heat dissipation | 8 W<br />2.2…2.5 W |
Operating time | 40...65 ms closing with LX1/LX9 coil<br />100...170 ms opening with LX1/LX9 coil<br />40...50 ms closing with LX4 coil<br />40...65 ms opening with LX4 coil<br />40...80 ms closing with LXE coil<br />6...54 ms opening with LXE coil | Mounting Support | Plate |
Standards | IEC 60947-1<br />IEC 60947-4-1<br />JIS C8201-4-1<br />EN 60947-1<br />EN 60947-4-1 | Product Certifications | ABS<br />CB<br />DNV<br />RMRoS<br />UL<br />CSA<br />RINA<br />LROS (Lloyds register of shipping)<br />BV<br />UKCA |
Connections - terminals | Power circuit bar 2 32 x 4 mm<br />Power circuit lugs-ring terminals 1 0.4 in² (240 mm²)<br />Power circuit connector 1 0.4 in² (240 mm²)<br />Power circuit bolted connection<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)<br />Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1.0 0.0004…0.004 in² (0.25…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)solid without cable end | Tightening torque | Power circuit 309.8 lbf.in (35 N.m)<br />Control circuit 10.6 lbf.in (1.2 N.m)<br />Control circuit 5.3 lbf.in (0.6 N.m) |
Mechanical durability | 10 Mcycles | Inrush power in VA | 600…700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil<br />655…803 VA (at 68 °F (20 °C))with LX4 coil<br />300…350 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil<br />300…310 VA (at 68 °F (20 °C))with LXE coil |
Hold-in power consumption in VA | 8…10 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil<br />3.68…4.53 VA (at 68 °F (20 °C))with LX4 coil<br />4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil<br />2.5…4.0 VA (at 68 °F (20 °C))with LXE coil | Maximum operating rate | 2400 cyc/h 131 °F (55 °C) |
compatibility code | LC1F | [Ue] rated operational voltage | <= 1000 V AC-1<br /><= 690 V AC-3<br /><= 690 V AC-4<br /><= 460 V DC |
IP degree of protection | IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106 | Protective treatment | TH |
Ambient Air Temperature for Operation | 23…131 °F (-5…55 °C) | Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
Permissible ambient air temperature around the device | -40…158 °F (-40…70 °C) | Operating altitude | 9842.52 ft (3000 m) without derating |
Mechanical robustness | Vibrations contactor open2 Gn, 5...300 Hz<br />Vibrations contactor closed5 Gn, 5...300 Hz<br />Shocks contactor open6 Gn for 1/2 sine wave (11 ms)<br />Shocks contactor closed15 Gn for 1/2 sine wave (11 ms) | Height | 8.0 in (203 mm) |
Width | 9.6 in (244.5 mm) | Depth | 8.4 in (213 mm) |
Net Weight | 18.83 lb(US) (8.54 kg) |