schneider LC1F2654E7

Selling Points

  • 1Operates at up to 2400 cycles/hour for reliable performance.
  • 2Compatible with environments up to 55°C, ensuring durability in various settings.
  • 3Suitable for resistive loads, large motor starting applications, and non-inductive loads.
  • 4Includes isolated N.C. trip contact, N.O. alarm contact, manual reset button, and rotary dial for adjustable current settings.
  • 5Meets IEC 60947-4-1 and VDE 0110 group C insulation voltage standards, with 1000 V rated impulse withstand voltage.
Product Details
LC1F2654E7
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
[Ue] rated operational voltage
<= 1000 V AC-1<br /><= 690 V AC-3<br /><= 690 V AC-4<br /><= 460 V DC
[Uc] control circuit voltage
48 V AC 40...400 Hz
[Ie] rated operational current
350 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
350 A (at 104 °F (40 °C))
Rated breaking capacity
2120 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
2200 A 104 °F (40 °C) - 10 s<br />1230 A 104 °F (40 °C) - 30 s<br />950 A 104 °F (40 °C) - 1 min<br />620 A 104 °F (40 °C) - 3 min<br />480 A 104 °F (40 °C) - 10 min
Associated fuse rating
315 A aM at <= 440 V<br />400 A gG at <= 440 V
Average impedance
0.3 mOhm - Ith 350 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
37 W AC-1
Overvoltage category
III
power pole contact composition
4 NO
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))<br />Drop-out 0.15...0.2 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability
10 Mcycles
Inrush power in VA
650 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA
10 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Operating time
40...65 ms closing<br />100...170 ms opening
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 32 x 4 mm<br />Power circuit lugs-ring terminals 1 0.4 in² (240 mm²)<br />Power circuit connector 1 0.4 in² (240 mm²)<br />Power circuit bolted connection
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 309.8 lbf.in (35 N.m)
Mounting Support
Plate
Heat dissipation
8 W
Standards
IEC 60947-1<br />IEC 60947-4-1<br />JIS C8201-4-1<br />EN 60947-4-1<br />EN 60947-1
Product Certifications
DNV<br />LROS (Lloyds register of shipping)<br />ABS<br />RMRoS<br />CB<br />BV<br />RINA<br />CCC<br />UL
compatibility code
LC1F
Control circuit type
AC 40...400 Hz
IP degree of protection
IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23…131 °F (-5…55 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C)
Height
8.0 in (203 mm)
Width
9.6 in (244.5 mm)
Depth
8.4 in (213 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
18.83 lb(US) (8.54 kg)

Specifications may be subject to change without notice