schneider LC1F400UD

Selling Points

  • 1High reliability and durability in environments up to 55°C.
  • 2Multi-standard certified (IEC, UL, CSA, CCC, EAC, Marine).
  • 3No coil required for later selection and installation.
  • 4Easy installation and maintenance with a drawer for coil insertion.
  • 5Compatible with a large choice of add-on blocks and accessories.
Product Details
LC1F400UD
schneider

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Range
TeSys
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load<br />Motor control
Utilisation category
AC-1<br />AC-3
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /><= 460 V DC
[Uc] control circuit voltage
250 V DC
[Ie] rated operational current
500 A (at <104 °F (40 °C)) at <= 440 V AC AC-1<br />400 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
500 A (at 104 °F (40 °C))
Rated breaking capacity
3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3600 A 104 °F (40 °C) - 10 s<br />2400 A 104 °F (40 °C) - 30 s<br />1700 A 104 °F (40 °C) - 1 min<br />1200 A 104 °F (40 °C) - 3 min<br />1000 A 104 °F (40 °C) - 10 min
Associated fuse rating
400 A aM at <= 440 V<br />500 A gG at <= 440 V
Average impedance
0.26 mOhm - Ith 500 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Power dissipation per pole
65 W AC-1<br />42 W AC-3
Overvoltage category
III
power pole contact composition
3 NO
Motor power kW
200 kW at 380...400 V AC 50/60 Hz (AC-3)<br />220 kW at 415 V AC 50/60 Hz (AC-3)<br />250 kW at 440 V AC 50/60 Hz (AC-3)<br />257 kW at 500 V AC 50/60 Hz (AC-3)<br />280 kW at 660...690 V AC 50/60 Hz (AC-3)<br />185 kW at 1000 V AC 50/60 Hz (AC-3)<br />110 kW at 220...230 V AC 50/60 Hz (AC-3)
Control circuit voltage limits
Operational 0.85...1.1 Uc 131 °F (55 °C))<br />Drop-out 0.2...0.35 Uc 131 °F (55 °C))
Mechanical durability
10 Mcycles
Inrush power in W
1000 W 68 °F (20 °C))
Hold-in power consumption in W
6 W 68 °F (20 °C)
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Operating time
50...60 ms closing<br />45...60 ms opening
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 30 x 5 mm<br />Power circuit lugs-ring terminals 2 0.2 in² (150 mm²)
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 309.8 lbf.in (35 N.m)
Mounting Support
Plate
Heat dissipation
6 W
Standards
IEC 60947-1<br />EN 60947-4-1<br />IEC 60947-4-1<br />EN 60947-1<br />JIS C8201-4-1
Product Certifications
UL<br />DNV<br />CCC<br />ABS<br />RINA<br />LROS (Lloyds register of shipping)<br />RMRoS<br />BV<br />CB
compatibility code
LC1F
Control circuit type
DC standard
IP degree of protection
IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23…131 °F (-5…55 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C)
Height
8.1 in (206 mm)
Width
8.4 in (213 mm)
Depth
8.6 in (219 mm)
Operating altitude
9842.52 ft (3000 m) without derating
Net Weight
20.06 lb(US) (9.1 kg)

Specifications may be subject to change without notice